Michael Saemann

Mr. Michael Saemann

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 March 2020 in Materials
Verified
Journal Article
Open access
PDF file
DVDanny Vogel
Danny Vogel
MKMatthias Klimek
Matthias Klimek
MSMichael Saemann
Michael Saemann
RBRainer Bader
Rainer Bader
In total hip arthroplasty, excessive acetabular cup deformations and altered strain distribution in the adjacent bone are potential risk factors for implant loosening. Materials with reduced stiffness might alter the strain distribution less, whereas shell and liner deformations might increase. The purpose of our current computational study was to evaluate whether carbon fiber-reinforced poly-ether-ether-ketones with a Young´s modulus of 15 GPa (CFR-PEEK-15) and 23 GPa (CFR-PEEK-23) might be an alternative shell material compared to titanium in terms of shell and liner deformation, as well as strain distribution in the adjacent bone. Using a finite element analysis, the press-fit implantation of modular acetabular cups with shells made of titanium, CFR-PEEK-15 and CFR-PEEK-23 in a human hemi-pelvis model was simulated. Liners made of ceramic and polyethylene were simulated. Radial shell and liner deformations as well as strain distributions were analyzed. The shells made of CFR-PEEK-15 were deformed most (266.7 µm), followed by CFR-PEEK-23 (136.5 µm) and titanium (54.0 µm). Subsequently, the ceramic liners were radially deformed by up to 4.4 µm and the polyethylene liners up to 184.7 µm. The shell materials slightly influenced the strain distribution in the adjacent bone with CFR-PEEK, resulting in less strain in critical regions (3000 µm/m) and more strain in bone building or sustaining regions (400 to 3000 µm/m), while the liner material only had a minor impact. The superior biomechanical properties of the acetabular shells made of CFR-PEEK could not be determined in our present study.

12 May 2022 in Gels
Verified
Journal Article
Open access
PDF file
JRJohanna Romischke
Johanna Romischke
ASAnton Scherkus
Anton Scherkus
MSMichael Saemann
Michael Saemann
SKSimone Krueger
Simone Krueger
RBRainer Bader
Rainer Bader
JMJohanna Meyer
Johanna Meyer
Hydrogels have become an increasingly interesting topic in numerous fields of application. In addition to their use as immobilization matrixes in (bio)catalysis, they are widely used in the medical sector, e.g., in drug delivery systems, contact lenses, biosensors, electrodes, and tissue engineering. Cartilage tissue engineering hydrogels from natural origins, such as collagen, hyaluronic acid, and gelatin, are widely known for their good biocompatibility. However, they often lack stability, reproducibility, and mechanical strength. Synthetic hydrogels, on the other hand, can have the advantage of tunable swelling and mechanical properties, as well as good reproducibility and lower costs. In this study, we investigated the swelling and mechanical properties of synthetic polyelectrolyte hydrogels. The resulting characteristics such as swelling degree, stiffness, stress, as well as stress-relaxation and cyclic loading behavior, were compared to a commercially available biomaterial, the ChondroFiller® liquid, which is already used to treat articular cartilage lesions. Worth mentioning are the observed good reproducibility and high mechanical strength of the synthetic hydrogels. We managed to synthesize hydrogels with a wide range of compressive moduli from 2.5 ± 0.1 to 1708.7 ± 67.7 kPa, which addresses the span of human articular cartilage.

25 February 2021 in Materials
Verified
Journal Article
Open access
PDF file
JWJanine Waletzko-Hellwig
Janine Waletzko-Hellwig
MSMichael Saemann
Michael Saemann
MSMarko Schulze
Marko Schulze
BFBernhard Frerich
Bernhard Frerich
RBRainer Bader
Rainer Bader
MDMichael Dau
Michael Dau
One main disadvantage of commercially available allogenic bone substitute materials is the altered mechanical behavior due to applied material processing, including sterilization methods like thermal processing or gamma irradiation. The use of high hydrostatic pressure (HHP) might be a gentle alternative to avoid mechanical alteration. Therefore, we compressed ground trabecular human bone to granules and, afterwards, treated them with 250 and 300 MPa for 20 and 30 min respectively. We characterized the formed bone granule cylinders (BGC) with respect to their biomechanical properties by evaluating stiffness and stress at 15% strain. Furthermore, the stiffness and yield strength of HHP-treated and native human trabecular bone cylinders (TBC) as control were evaluated. The mechanical properties of native vs. HHP-treated TBCs as well as HHP-treated vs. untreated BGCs did not differ, independent of the applied HHP magnitude and duration. Our study suggests HHP treatment as a suitable alternative to current processing techniques for allogenic bone substitutes since no negative effects on mechanical properties occurred.

1 February 2022 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Closed access
NHN.S. Hennicke
N.S. Hennicke
MSMichael Saemann
Michael Saemann
DKDaniel Kluess
Daniel Kluess
RBR. Bader
R. Bader
MSM. Sander
M. Sander

1 January 2022 in Clinical Biomechanics
Verified
Journal Article
Closed access
MSMichael Saemann
Michael Saemann
MDMartin Darowski
Martin Darowski
NHNina S. Hennicke
Nina S. Hennicke
RBRainer Bader
Rainer Bader
MSManuela Sander
Manuela Sander
DKDaniel Kluess
Daniel Kluess