Dislocation remains a serious complication of total hip replacement. An insufficient range of motion can lead to impingement of the prosthetic neck on the acetabular cup. Together with the initiation of subluxation and dislocation, recurrent impingement can cause material failure in the liner. The objective of this study was to generate a validated finite element (FE) model capable of predicting the dislocation stability of different femoral head sizes with regard to impingement in different implant positions as well as the corresponding stress distribution in the liner. In order to cover posterior and anterior dislocation, two total hip dislocation associated manoeuvres were simulated using a three-dimensional nonlinear finite element model. The dislocation stability of two head sizes was determined numerically and experimentally. After validation, the FE model was used to analyse the dislocation stability of four different head sizes in variable implant positions. Range of motion (ROM) until impingement, the resisting moment that was developed and ROM until dislocation were evaluated. Additionally, stress distribution within the polyethylene liner during impingement and subluxation was determined. For both dislocation modes, a cup position of 45 degrees lateral abduction and 15 degrees up to 30 degrees anteversion resulted in appropriate ROM and dislocation stability. In general, larger head diameters revealed an increase in ROM and higher resisting moments. Stress analysis showed decreased contact pressures at the egress site of the liners with the larger inner diameters during subluxation. The analysis shows that an optimal implant position and a larger head diameter can reduce the risk of dislocation induced by impingement. The finite element model that was developed enables simplification of design variations compared to experimental studies since prototyping and assembling are replaced by prompt numerical simulation.
1 July 2009 in Computer Methods and Programs in Biomedicine
The formation of titanium (Ti)-wear particles during the lifetime of an implant is believed to be a major component of loosening due to debris-induced changes in bone cell function. Radiographic evidence indicates a loss of fixation at the implant–bone interface, and we believe that the accumulation of Ti particles may act on the bone-remodeling process and impact both long- and short-term implant-fixation strengths. To determine the effects of various sizes of the Ti particles on osteoblast function in vivo , we measured the loss of integration strength around Ti-pin implants inserted into a rat tibia in conjunction with Ti particles from one of four size-groups. Implant integration is mediated primarily by osteoblast adhesion/focal contact pattern, viability, proliferation and differentiation, and osteoclast recruitment at the implant site in vivo . This study demonstrates the significant attenuation of osteoblast function concurrent with increased expression of receptor activator of nuclear factor κB ligand (RANKL), a dominant signal for osteoclast recruitment, which is regulated differentially, depending on the size of the Ti particle. Zymography studies have also demonstrated increased activities of matrix metalloproteinases (MMP) 2 and 9 in cells exposed to larger Ti particles. In summary, all particles have adverse effects on osteoblast function, resulting in decreased bone formation and integration, but different mechanisms are elicited by particles of different sizes.
Finite element analysis (FEA) has become a fundamental tool for biomechanical investigations in the last decades. Despite several existing initiatives and guidelines for reporting on research methods and results, there are still numerous issues that arise when using computational models in biomechanical investigations. According to our knowledge, these problems and controversies lie mainly in the verification and validation (V&V) process as well as in the set-up and evaluation of FEA. This work aims to introduce a checklist including a report form defining recommendations for FEA in the field of Orthopedic and Trauma (O&T) biomechanics. Therefore, a checklist was elaborated which summarizes and explains the crucial methodologies for the V&V process. In addition, a report form has been developed which contains the most important steps for reporting future FEA. An example of the report form is shown, and a template is provided, which can be used as a uniform basis for future documentation. The future application of the presented report form will show whether serious errors in biomechanical investigations using FEA can be minimized by this checklist. Finally, the credibility of the FEA in the clinical area and the scientific exchange in the community regarding reproducibility and exchangeability can be improved.
Background and purpose Hip resurfacing arthroplasty is being used more and more frequently. The small ratio in size between the resurfaced femoral head and the relatively thick femoral neck raises the question of whether the range of motion is sufficient, particularly with regard to the high mobility required by younger patients. We analyzed motion in a CAD model. Methods Three-dimensional CAD models of the natural hip were created from CT scans and 8 designs of hip resurfacing prostheses (head diameter between 42 mm and 54 mm combined with a hemispherical cup) were implanted in a virtual sense. We simulated 3 different leg positions and the range of motion was evaluated, considering five different implant positions. Results The range of motion of the hip resurfacing designs analyzed was far below the range of motion of stemmed total hip prostheses. None of the resurfacing prostheses provided flexion movements of 90° without impingement. The average range of motion of hip resurfacing arthroplasty was 31–48° below the range of motion of a stemmed total hip replacement with 32-mm head diameter. Interpretation The range of motion of the hip resurfacing designs examined was substantially less than that of a conventional total hip prosthesis. Since impingement of the femoral neck on the acetabular component increases the risk of neck fractures, of dislocation and of subsequent implant loosening, the design and position of the implant should be considered before using hip resurfacing arthroplasty as a standard treatment for younger patients.
The present study contrasts the accuracy of different reconstructed models with distinctive segmentation methods performed by various experts. Seven research groups reconstructed nine 3D models of one human femur based on an acquired CT image using their own computational methods. As a reference model for accuracy assessment, a 3D surface scan of the human femur was created using an optical measuring system. Prior to comparison, the femur was divided into four areas; “neck and greater trochanter”, “proximal metaphysis”, “diaphysis”, and “distal metaphysis”. The deviation analysis was carried out in GEOMAGIC studio v.2013 software. The results revealed that the highest deviation errors occurred in “neck and greater trochanter” area and “proximal metaphysis” area with RMSE of 0.84 and 0.83 mm respectively. In conclusion, this study shows that the average deviation of reconstructed models prepared by experts with various methods, skills and software from the surface 3D scan is lower than 0.79 mm, which is not a significant discrepancy.