Virtual inertia is known as an inevitable part of the modern power systems with high penetration of renewable energy. Recent trend of research is oriented in different methods of emulating the inertia to increase the sustainability of the system. In the case of dynamic performance of power systems especially in Automatic Generation Control (AGC) issue, there are concerns considering the matter of virtual inertia. This paper proposes an approach for analyzing the dynamic effects of virtual inertia in two-area AC/DC interconnected AGC power systems. Derivative control technique is used for higher level control application of inertia emulation. This method of inertia emulation is developed for two-area AGC system, which is connected by parallel AC/DC transmission systems. Based on the proposed technique, the dynamic effect of inertia emulated by storage devices for frequency and active power control are evaluated. The effects of frequency measurement delay and phase-locked loop effect are also considered by introducing a second-order function. Simulations performed by MATLAB software demonstrate how virtual inertia emulation can effectively improve the performance of the power system. A detailed eigenvalue analysis is also performed to support the positive effects of the proposed method.
1 April 2016 in IET Generation, Transmission & Distribution
Due to increasing level of power converter‐based component and consequently the lack of inertia, automatic generation control (AGC) of interconnected systems is experiencing different challenges. To cope with this challenging issue, a derivative control‐based virtual inertia for simulating the dynamic effects of inertia emulations by HVDC (high‐voltage direct current) interconnected systems is introduced and reflected in the multi‐area AGC system. Derivative control technique is used for higher level applications of inertia emulation. The virtual inertia will add an additional degree of freedom to the system dynamics which makes a considerable improvement on first overshoot responses in addition to damping characteristics of HVDC links. Complete trajectory sensitivities are used to analyse the effects of virtual inertia and derivative control gains on the system stability. The effectiveness of the proposed concept on dynamic improvements is tested through Matlab simulation of two‐area test system for different contingencies.
20 July 2016 in IEEE Transactions on Power Systems
Automatic generation control (AGC) in multi-area interconnected power systems is experiencing several adaptions due to increasing level of power converter based components in the system. The concept of virtual synchronous power (VSP) to simulate the dynamic effects of virtual inertia emulations by HVDC links for higher level control applications is introduced and reflected in the multi-area AGC model. By using this proposed combination in the AGC model, the dynamic performance of the studied system shows a significant improvement. The proposed formulation is generalized for multi-area systems with multiple HVDC links. The active power loop control in VSP-based HVDC links has a second-order characteristic, which makes a simultaneous enabling of damping and inertia emulations into the system. Trajectory sensitivities are also used to analyze the effects of VSP's parameters on the system stability. The effectiveness of the proposed concept on dynamic improvements is tested through MATLAB simulation of a four-area system.
1 December 2019 in Energy Conversion and Management
This paper reports a general overview of current research on analysis and control of the power grid with grid scale PV-based power generations as well as of various consequences of grid scale integration of PV generation units into the power systems. Moreover, the history of PV renewable growth, deregulation of power system and issues related to grid-connected PV systems considering its contribution to various responsibilities like frequency control, virtual inertia capabilities and voltage regulation are discussed. Moreover, various outcomes of the high-penetrated grid with PV power plants such as power quality, active and reactive power control, protection, balancing and reliability under various loading conditions are reviewed and discussed.