This paper proposes a generalized voltage droop (GVD) control strategy for dc voltage control and power sharing in voltage source converter (VSC)-based multiterminal dc (MTDC) grids. The proposed GVD control is implemented at the primary level of a two-layer hierarchical control structure of the MTDC grid, and constitutes an alternative to the conventional voltage droop characteristics of voltage-regulating VSC stations, providing higher flexibility and, thus, controllability to these networks. As a difference with other methods, the proposed GVD control strategy can be operated in three different control modes, including conventional voltage droop control, fixed active power control, and fixed dc voltage control, by adjusting the GVD characteristics of the voltage-regulating converters. Such adjustment is carried out in the secondary layer of the hierarchical control structure. The proposed strategy improves the control and power-sharing capabilities of the conventional voltage droop, and enhances its maneuverability. The simulation results, obtained by employing a CIGRE B4 dc grid test system, demonstrate the efficiency of the proposed approach and its flexibility in active power sharing and power control as well as voltage control. In these analysis, it will be also shown how the transitions between the operating modes of the GVD control does not give rise to active power oscillations in the MTDC grids.
11 July 2014 in IEEE Journal of Emerging and Selected Topics in Power Electronics
This paper proposes an effective dc voltage and power-sharing control structure for multiterminal dc (MTDC) grids based on an optimal power flow (OPF) procedure and voltage-droop control implemented in the different hierarchical layers. In the proposed approach, an OPF algorithm is executed at the secondary control level of the MTDC grid to find the optimal reference values for the dc voltages and active power of the voltage-regulating converters. Then, at the primary control level, the voltage-droop characteristics of the voltage-regulating converters are tuned based upon the OPF results. In this control structure, the optimally-tuned voltage-droop controllers lead to the optimal operation of the MTDC grid. In case of variation in load or generation of the grid, a new stable operating point is achieved based on the voltage-droop characteristics. Then by executing a new OPF, the voltage-droop characteristics are returned for optimal operation of the MTDC grid after the load or generation variations. This paper also considers the integration of frequency support loop in the proposed control framework in case of connection of weak ac grids. The simulations performed on a study case inspired by the CIGRE B4 dc grid test system demonstrate the efficient grid performance under the proposed control strategy.
19 April 2021 in IEEE Transactions on Power Electronics
High voltage direct current (HVDC) systems are now well integrated into AC systems in many jurisdictions. The integration of renewable energy sources (RESs) is a major focus and the role of HVDC systems is expanding. However, the protection of HVDC systems against DC faults is a challenging issue that can have negative impacts on the reliable and safe operation of power systems. Practical solutions to protect HVDC grids against DC faults without a widespread power outage include: 1) using DC circuit breakers (CBs) to isolate the faulty DC-link, 2) using a proper converter topology to interrupt the DC fault current, and/or 3) using high-power DC transformers and DC hubs at strategic points within DC grids. The application of HVDC CBs is identified as the best approach that satisfies both DC grids and connected AC grids' requirements. This article reports a comprehensive review of HVDC CBs technologies, including recent significant attempts in the development of modern HVDC CBs. The functional analysis of each technology is presented. Additionally, different technologies based on information obtained from literature are compared. Finally, recommendations for the improvement of CBs are presented.
This paper reports a general overview of current research on analysis and control of the power grid with grid scale PV-based power generations as well as of various consequences of grid scale integration of PV generation units into the power systems. Moreover, the history of PV renewable growth, deregulation of power system and issues related to grid-connected PV systems considering its contribution to various responsibilities like frequency control, virtual inertia capabilities and voltage regulation are discussed. Moreover, various outcomes of the high-penetrated grid with PV power plants such as power quality, active and reactive power control, protection, balancing and reliability under various loading conditions are reviewed and discussed.
8 July 2017 in Journal of Modern Power Systems and Clean Energy
A few multi-terminal direct current (MTDC) systems are in operation around the world today. However, MTDC grids overlaying their AC counterpart might a reality in a near future. The main drivers for constructing such direct current grids are the large-scale integration of remote renewable energy resources into the existing alternative current (AC) grids, and the promotion and development of international energy markets through the so-called supergrids. This paper presents the most critical challenges and prospects for such emerging MTDC grids, along with a foreseeable technology development roadmap, with a particular focus on crucial control and operational issues that are associated with MTDC systems and grids.
21 January 2019 in IEEE Transactions on Power Delivery
Expansion of high-voltage dc (HVdc) systems to multi-terminal HVdc (MT-HVdc) systems/grids considerably increases the short circuit levels. In order to protect the emerging MT-HVdc systems/grids against fault currents, proper dc fault current limiters (FCLs) must be developed. This paper proposes an innovative high inductance solid-state dc-reactor based fault current limiter (HISS-DCRFCL) to be used in HVdc applications. In fact, during the HISS-DCRFCL normal operation, its inductance value is extremely low, and its value becomes considerably high during the fault period, which decreases the fault current amplitude. The proposed HISS-DCRFCL performance is analyzed by MATLAB/Simulink and the simulation results are verified and confirmed by laboratory experimental results using a scaled-down laboratory prototype setup.