Amged Al Ezzi

Dr. Amged Al Ezzi

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 December 2021 in Energies
Verified
Journal Article
Open access
PDF file
GAGazy F. Al-sumaily
Gazy F. Al-sumaily
AEAmged Al Ezzi
Amged Al Ezzi
HDhayder dhahad
hayder dhahad
MTMark C. Thompson
Mark C. Thompson
Talal YusafTalal Yusaf
Talal Yusaf
Local thermal equilibrium (LTE) is a frequently-employed hypothesis when analysing convection heat transfer in porous media. However, investigation of the non-equilibrium phenomenon exhibits that such hypothesis is typically not true for many circumstances such as rapid cooling or heating, and in industrial applications involving immediate transient thermal response, leading to a lack of local thermal equilibrium (LTE). Therefore, for the sake of appropriately conduct the technological process, it has become necessary to examine the validity of the LTE assumption before deciding which energy model should be used. Indeed, the legitimacy of the LTE hypothesis has been widely investigated in different applications and different modes of heat transfer, and many criteria have been developed. This paper summarises the studies that investigated this hypothesis in forced, free, and mixed convection, and presents the appropriate circumstances that can make the LTE hypothesis to be valid. For example, in forced convection, the literature shows that this hypothesis is valid for lower Darcy number, lower Reynolds number, lower Prandtl number, and/or lower solid phase thermal conductivity; however, it becomes invalid for higher effective fluid thermal conductivity and/or lower interstitial heat transfer coefficient.

24 May 2022 in Energies
Verified
Journal Article
Open access
PDF file
AEAmged Al Ezzi
Amged Al Ezzi
Miqdam Tariq ChaichanMiqdam Tariq Chaichan
Miqdam Tariq Chaichan
HMHasan S. Majdi
Hasan S. Majdi
HKHussein Kazem
Hussein Kazem
HKHussein Kazem
Hussein Kazem
Talal YusafTalal Yusaf
Talal Yusaf
Both electrical and thermal efficiencies combine in determining and evaluating the performance of a PV/T collector. In this study, two PV/T systems consisting of poly and monocrystalline PV panels were used, which are connected from the bottom by a heat exchanger consisting of a spiral tube through which a nanofluid circulates. In this study, a base fluid, water, and ethylene glycol were used, and iron oxide nanoparticles (nano-Fe2O3) were used as an additive. The mixing was carried out according to the highest specifications adopted by the researchers, and the thermophysical properties of the fluid were carefully examined. The prepared nanofluid properties showed a limited effect of the nanoparticles on the density and viscosity of the resulting fluid. As for the thermal conductivity, it increased by increasing the mass fraction added to reach 140% for the case of adding 2% of nano-Fe2O3. The results of the zeta voltage test showed that the supplied suspensions had high stability. When a mass fraction of 0.5% nano-Fe2O3 was added the zeta potential was 68 mV, while for the case of 2%, it reached 49 mV. Performance tests showed a significant increase in the efficiencies with increased mass flow rate. It was found when analyzing the performance of the two systems for nanofluid flow rates from 0.08 to 0.17 kg/s that there are slight differences between the monocrystalline, and polycrystalline systems operating in the spiral type of exchanger. As for the case of using monocrystalline PV the electrical, thermal, and total PV/T efficiencies with 2% added Fe2O3 ranged between 10% to 13.3%, 43–59%, and 59 to 72%, respectively, compared to a standalone PV system. In the case of using polycrystalline PV, the electrical, thermal, and total PV/T efficiencies ranged from 11% to 13.75%, 40.3% to 63%, and 55.5% to 77.65%, respectively, compared to the standalone PV system. It was found that the PV/T electrical exergy was between 45, and 64 W with thermal exergy ranged from 40 to 166 W, and total exergy from 85 to 280 W, in the case of using a monocrystalline panel. In the case of using polycrystalline, the PV/T electrical, thermal, and total exergy were between 45 and 66 W, 42–172 W, and 85–238 W, respectively. The results showed that both types of PV panels can be used in the harsh weather conditions of the city of Baghdad with acceptable, and efficient productivity.

21 September 2023 in Sustainability
Verified
Journal Article
Open access
PDF file
FFFarah G. Fahad
Farah G. Fahad
SAShurooq talib Al-Humairi
Shurooq talib Al-Humairi
AEAmged Al Ezzi
Amged Al Ezzi
HMHasan Majdi
Hasan Majdi
Abbas J. SultanAbbas J. Sultan
Abbas J. Sultan
TAThaar Mohammad Aljuwaya
Thaar Mohammad Aljuwaya
Desiccant agents (DAs) have drawn much interest from researchers and businesses because they offer a potential method for lowering environmental impact, increasing energy efficiency, and controlling humidity. As a result, they provide a greener option to conventional air conditioning systems. This review thoroughly analyzes current issues, obstacles, and future advancements in liquid desiccant agents (LDAs) for drying, air conditioning, and dehumidification applications. The importance of LDAs in lowering energy use and greenhouse gas emissions is highlighted, emphasizing their potential for environmentally friendly humidity control. The current review examines key parameters such as novel materials, enhancing desiccant qualities, integration with technologies, and long-term durability while examining recent developments in LDAs and investigating their applications in diverse industries. The main conclusions from the evaluated publications in this review are also highlighted, including developments in LDAs, new applications, and developing research fields. Overall, this review advances knowledge of LDAs and their potential to shift humidity control systems toward sustainability and energy efficiency.

25 May 2022 in International Journal of Thermofluids
Verified
Journal Article
Open access
AEAmged Al Ezzi
Amged Al Ezzi
LILaith Ismael
Laith Ismael
MFMohammed A. Fayad
Mohammed A. Fayad
AJAlaa Abdulhady Jaber
Alaa Abdulhady Jaber
Ayad M. Al JuboriAyad M. Al Jubori
Ayad M. Al Jubori
Talal YusafTalal Yusaf
Talal Yusaf

18 October 2023
Verified
Book Chapter
Closed access
PDF file
AEAmged Al Ezzi
Amged Al Ezzi
Hasanain A. Abdul WahhabHasanain A. Abdul Wahhab
Hasanain A. Abdul Wahhab
RJRaed A. Jessam
Raed A. Jessam

1 January 2022 in SSRN Electronic Journal
Verified
Preprint
Open access
PDF file
AEAmged Al Ezzi
Amged Al Ezzi
LILaith Ismael
Laith Ismael
MFMohammed A. Fayad
Mohammed A. Fayad
Alaa Abdulhady JaberAlaa Abdulhady Jaber
Alaa Abdulhady Jaber
Ayad M. Al JuboriAyad M. Al Jubori
Ayad M. Al Jubori
TYTalal Yusaf
Talal Yusaf
Zeolite desiccant particles are well known for their strong affinity to adsorb water vapor molecules; however, they require significant regeneration energy to be created. This paper presents an experimental study of the adsorption and regeneration processes of a monolayer zeolite for indoor dehumidification to the 13X zeolite beads with a 4 ́ 8 mesh bead size and a pore opening 10 A0 were used as this monolayer. An experimental investigation was conducted to determine the effects of the relative humidity, temperature, and air flow rate on the adsorption and regeneration processes. The results show the effectiveness of the monolayer coating method and the relative humidity significantly affects the adsorption process, and that the airflow rate surrounding and through the zeolite beads increases the adsorption and desorption of the water vapor molecules. In the absence of the meniscus radius formation due to the monolayer arrangement prevents external condensation. With an airflow rate of Re = 1773, the full adsorption process at a relative humidity of 99% was obtained within 37 minutes; meanwhile, the regeneration process proceeded at 100 o C within 66 minutes. The adsorption time was reduced by 27% and 43% as the Reynold number increases to 2586 and 3325, respectively. Likewise, the effectiveness of the regeneration time is decreased by 0.07% and 14% within the same Reynold number increases. Results obtained from this research can be used to guide the future development of polymer-coated energy exchangers.