Robotic football with humanoid robots is a multidisciplinary field connecting several scientific fields. A challenging task in the design of a humanoid robot for the AndroSot and HuroCup competitions is the realization of movement on the field. This study aims to determine a walking pattern for a humanoid robot with an impact on its dynamic stability and behavior. The design of the proposed technical concept depends on its stability management mechanism, walking speed and such factors as the chosen stability approaches. The humanoid robot and its versatility, along with the adaptability of the terrain, are somewhat limited due to the complexity of the walking principle and the control of the robot’s movement itself. The technical concept uses dynamic stability as the potential force of the inertial bodies and their parts so that the humanoid robot does not overturn. The total height of the robot according to the rules of the competition will be 50 cm. In the performed experiment, only the lower part of the humanoid robot with added weight was considered, which is more demanding due to the non-use of the upper limbs for stabilization. The performed experiment verified the correctness of the design, where the torso of the robot performed eight steps in inclinations of a roll angle +4/−2° and a pitch angle +4/−6°.
COVID-19 was first identified in December 2019 in Wuhan, China. It mainly affects the respiratory system and can lead to the death of the patient. The motivation for this study was the current pandemic situation and general deficiency of emergency mechanical ventilators. The paper presents the development of a mechanical ventilator and its control algorithm. The main feature of the developed mechanical ventilator is AmbuBag compressed by a pneumatic actuator. The control algorithm is based on an adaptive neuro-fuzzy inference system (ANFIS), which integrates both neural networks and fuzzy logic principles. Mechanical design and hardware design are presented in the paper. Subsequently, there is a description of the process of data collecting and training of the fuzzy controller. The paper also presents a simulation model for verification of the designed control approach. The experimental results provide the verification of the designed control system. The novelty of the paper is, on the one hand, an implementation of the ANFIS controller for AmbuBag pressure control, with a description of training process. On other hand, the paper presents a novel design of a mechanical ventilator, with a detailed description of the hardware and control system. The last contribution of the paper lies in the mathematical and experimental description of AmbuBag for ventilation purposes.
Technical solutions based on biological models are the subject of research by a wide range of experts and mainly concern their mechanical use. When designing a suitable actuator, they use the physical methods of biological representatives, of which a large group consists of actuators generally referred to as artificial muscles, while another group uses compressed air as an energy carrier. In order to perform the measurements described in this article, a test mechanism based on the opposing arrangement of a pair of pneumatic muscles was constructed. Measurements on the test mechanism were made at set constant pressures in the range of 0.4 MPa to 0.6 MPa, while at each pressure, measurements were made for the counterload range from 0 N to 107.87 N. The measured values were recorded using a microcontroller and subsequently processed into graphic outputs. As part of the measurements, a comparative measurement of the same opposite arrangement of a pair of linear double-acting pneumatic actuators with a single-sided piston rod was also performed. The experiment and measurements were carried out in order to determine the suitability of using pneumatic artificial muscles in the selected arrangement for the implementation of a mechanism imitating the human arm. The target parameters of the experiment were the reaction speed of the course of force when filling the muscle under load and the reaction of the mechanism to a change in the set pressure in the pneumatic system. The summary of the comparison of the measured results is the content of the discussion in this article.
The paper deals with the proposed concept of a biped robot with vertical stabilization of the robot’s base and minimization of its sideways oscillations. This robot uses 6 actuators, which gives good preconditions for energy balance compared to purely articulated bipedal robots. In addition, the used linear actuator is self-locking, so no additional energy is required for braking or to keep it in a stable position. The direct and inverse kinematics problems are solved by means of a kinematic model of the robot. Furthermore, the task is aided by a solution for locomotion on an inclined plane. Special attention is focused on the position of the robot’s center of gravity and its stability in motion. The results of the simulation confirm that the proposed concept meets all expectations. This robot can be used as a mechatronic assistant or as a carrier for handling extensions.
This paper addresses the issue of the verification and comparison of the selected properties of a newly developed electric actuator. This actuator is intended to act as the drive of a walking robot designed for robotic football. Its envisioned placement is inside the robot’s knee joint and in its upper part. An integral part of the actuator is a harmonic precision gearbox and an absolute rotation sensor. The prototype of the newly developed actuator consists of both aluminum and 3D-printed parts. The selected parameters were verified according to the selected characteristics of ISO standard 9283, namely a one-directional pose accuracy and repeatable pose accuracy. The obtained data were compared with those of the standard actuator used thus far in constructing robots for robotic football. The implemented verification is based on the need to improve the performance parameters of the actuator while ensuring the sufficient accuracy of stopping the actuator in the required position. This is ensured by the use of a more accurate harmonic reducer and rotation sensor compared to the standard actuator.
1 January 2011 in ANNALS OF THE ORADEA UNIVERSITY. Fascicle of Management and Technological Engineering.