J. Isabelle Choi

Dr. J. Isabelle Choi


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 July 2021 in Cancers
Verified
Journal Article
Open access
PDF file
Minglei KangMinglei Kang
Minglei Kang
AWAlex Wei
Alex Wei
JCJ. Isabelle Choi
J. Isabelle Choi
CSCharles Simone
Charles Simone
HLHaibo Lin
Haibo Lin
To quantitatively assess target and organs-at-risk (OAR) dose rate based on three proposed proton PBS dose rate metrics and study FLASH intensity-modulated proton therapy (IMPT) treatment planning using transmission beams. An in-house FLASH planning platform was developed to optimize transmission (shoot-through) plans for nine consecutive lung cancer patients previously planned with proton SBRT. Dose and dose rate calculation codes were developed to quantify three types of dose rate calculation methods (dose-averaged dose rate (DADR), average dose rate (ADR), and dose-threshold dose rate (DTDR)) based on both phantom and patient treatment plans. Two different minimum MU/spot settings were used to optimize two different dose regimes, 34-Gy in one fraction and 45-Gy in three fractions. The OAR sparing and target coverage can be optimized with good uniformity (hotspot < 110% of prescription dose). ADR, accounting for the spot dwelling and scanning time, gives the lowest dose rate; DTDR, not considering this time but a dose-threshold, gives an intermediate dose rate, whereas DADR gives the highest dose rate without considering any time or dose-threshold. All three dose rates attenuate along the beam direction, and the highest dose rate regions often occur on the field edge for ADR and DTDR, whereas DADR has a better dose rate uniformity. The differences in dose rate metrics have led a large variation for OARs dose rate assessment, posing challenges to FLASH clinical implementation. This is the first attempt to study the impact of the dose rate models, and more investigations and evidence for the details of proton PBS FLASH parameters are needed to explore the correlation between FLASH efficacy and the dose rate metrics.

18 November 2021 in Cancers
Verified
Journal Article
Open access
PDF file
AWAlex Wei
Alex Wei
HLHaibo Lin
Haibo Lin
JCJ. Isabelle Choi
J. Isabelle Choi
CSCharles Simone
Charles Simone
Minglei KangMinglei Kang
Minglei Kang
Purpose: While transmission proton beams have been demonstrated to achieve ultra-high dose rate FLASH therapy delivery, they are unable to spare normal tissues distal to the target. This study aims to compare FLASH treatment planning using single energy Bragg peak proton beams versus transmission proton beams in lung tumors and to evaluate Bragg peak plan optimization, characterize plan quality, and quantify organ-at-risk (OAR) sparing. Materials and Methods: Both Bragg peak and transmission plans were optimized using an in-house platform for 10 consecutive lung patients previously treated with proton stereotactic body radiation therapy (SBRT). To bring the dose rate up to the FLASH-RT threshold, Bragg peak plans with a minimum MU/spot of 1200 and transmission plans with a minimum MU/spot of 400 were developed. Two common prescriptions, 34 Gy in 1 fraction and 54 Gy in 3 fractions, were studied with the same beam arrangement for both Bragg peak and transmission plans (n = 40 plans). RTOG 0915 dosimetry metrics and dose rate metrics based on different dose rate calculations, including average dose rate (ADR), dose-averaged dose rate (DADR), and dose threshold dose rate (DTDR), were investigated. We then evaluated the effect of beam angular optimization on the Bragg peak plans to explore the potential for superior OAR sparing. Results: Bragg peak plans significantly reduced doses to several OAR dose parameters, including lung V7.4Gy and V7Gy by 32.0% (p < 0.01) and 30.4% (p < 0.01) for 34Gy/fx plans, respectively; and by 40.8% (p < 0.01) and 41.2% (p < 0.01) for 18Gy/fx plans, respectively, compared with transmission plans. Bragg peak plans have ~3% less in DADR and ~10% differences in mean OARs in DTDR and DADR relative to transmission plans due to the larger portion of lower dose regions of Bragg peak plans. With angular optimization, optimized Bragg peak plans can further reduce the lung V7Gy by 20.7% (p < 0.01) and V7.4Gy by 19.7% (p < 0.01) compared with Bragg peak plans without angular optimization while achieving a similar 3D dose rate distribution. Conclusion: The single-energy Bragg peak plans achieve superior dosimetry performances in OARs to transmission plans with comparable dose rate performances for lung cancer FLASH therapy. Beam angle optimization can further improve the OAR dosimetry parameters with similar 3D FLASH dose rate coverage.

10 May 2019 in Cureus
Verified
Journal Article
Open access
PDF file
JCJ. Isabelle Choi
J. Isabelle Choi
JDJaneen Daniels
Janeen Daniels
DCDane Cohen
Dane Cohen
YLYing Li
Ying Li
CHChul S. Ha
Chul S. Ha
TETony Y. Eng
Tony Y. Eng
The clinical outcomes of patients treated with spatially fractionated GRID radiotherapy (SFGRT) for bulky tumors of the head and neck at a single institution were evaluated retrospectively. Endpoints of interest included tumor response, symptom improvement, treatment tolerance, and adverse events. Institutional review board approval was obtained prior to study initiation. The institutional database was queried for patients with tumors of the head and neck treated with SFGRT between August 2007 and April 2015. Medical records of identified patients were reviewed for treatment details and clinical endpoints of interest. SFGRT was delivered in one fraction of 15 gray (Gy) or 20 Gy; 6 megavolt (MV) or 18 MV photon beams were passed through a multileaf collimator (MLC)-based or brass GRID template. All patients had a planned course of conventionally-fractionated external beam radiotherapy (EBRT) to begin on the day following SFGRT delivery. Twenty-one consecutive patients meeting study criteria were identified. The most common tumor histology was squamous cell carcinoma. Median patient age was 59 years (range 13 - 83 years); median maximum tumor dimension was 9.5 centimeters (cm) (range 5.0 - 25.0 cm). Fifteen patients (71.4%) completed their full course of EBRT. Twelve patients were treated with palliative intent for local tumor symptoms, of which 54.5% experienced some degree of symptom improvement. Of nine patients treated with curative intent, 44.4% achieved a clinical complete response (CR). Concurrent chemotherapy was administered in 12 patients, with all patients being treated having definitively received chemotherapy. Radiation Therapy Oncology Group (RTOG) grade three or higher skin toxicity occurred in five patients; no grade five events were reported. Our institutional experience suggests that SFGRT is a feasible treatment option for the palliative or definitive management of large tumors of the head and neck. In combination with EBRT, SFGRT can provide timely symptom management and improve patient quality of life in the palliative setting. In the definitive setting, the addition of chemotherapy to SFGRT and EBRT can result in an excellent clinical response. Treatment toxicity was found to be within an acceptable range. When considering SFGRT for patients with these challenging presentations, careful patient selection is needed to identify those who will likely tolerate a full course of EBRT following SFGRT, as these patients are most likely to receive maximal benefit from SFGRT treatment. More data on the feasibility and efficacy of this radiation modality will be helpful for continued optimization of SFGRT delivery and patient selection.

28 July 2023 in Cancers
Verified
Journal Article
Open access
PDF file
MPMichael Pennock
Michael Pennock
AWAlex Wei
Alex Wei
CCChingyun Cheng
Chingyun Cheng
HLHaibo Lin
Haibo Lin
SHShaakir Hasan
Shaakir Hasan
RPRobert H. Press
Robert H. Press
Proton pencil-beam scanning (PBS) Bragg peak FLASH combines ultra-high dose rate delivery and organ-at-risk (OAR) sparing. This proof-of-principle study compared dosimetry and dose rate coverage between PBS Bragg peak FLASH and PBS transmission FLASH in head and neck reirradiation. PBS Bragg peak FLASH plans were created via the highest beam single energy, range shifter, and range compensator, and were compared to PBS transmission FLASH plans for 6 GyE/fraction and 10 GyE/fraction in eight recurrent head and neck patients originally treated with quad shot reirradiation (14.8/3.7 CGE). The 6 GyE/fraction and 10 GyE/fraction plans were also created using conventional-rate intensity-modulated proton therapy techniques. PBS Bragg peak FLASH, PBS transmission FLASH, and conventional plans were compared for OAR sparing, FLASH dose rate coverage, and target coverage. All FLASH OAR V40 Gy/s dose rate coverage was 90–100% at 6 GyE and 10 GyE for both FLASH modalities. PBS Bragg peak FLASH generated dose volume histograms (DVHs) like those of conventional therapy and demonstrated improved OAR dose sparing over PBS transmission FLASH. All the modalities had similar CTV coverage. PBS Bragg peak FLASH can deliver conformal, ultra-high dose rate FLASH with a two-millisecond delivery of the minimum MU per spot. PBS Bragg peak FLASH demonstrated similar dose rate coverage to PBS transmission FLASH with improved OAR dose-sparing, which was more pronounced in the 10 GyE/fraction than in the 6 GyE/fraction. This feasibility study generates hypotheses for the benefits of FLASH in head and neck reirradiation and developing biological models.

16 October 2024 in Cancers
Verified
Journal Article
Open access
PDF file
ACAdrian Wai Chan
Adrian Wai Chan
HLHaibo Lin
Haibo Lin
IYIrini Yacoub
Irini Yacoub
ACArpit M. Chhabra
Arpit M. Chhabra
JCJ. Isabelle Choi
J. Isabelle Choi
CSCharles Simone
Charles Simone
Background/Objectives: Uveal melanoma is the most common primary intraocular malignancy in adults. Treatment options for localized, early-stage disease include enucleation, brachytherapy, and proton beam therapy. This review aims to evaluate the role of proton therapy in the definitive management of uveal melanoma, focusing on its physics, radiobiology, treatment techniques, and associated outcomes. Methods: This narrative review synthesizes current literature on proton therapy for uveal melanoma, emphasizing case selection, treatment efficacy, and side effects. Results: Proton therapy offers significant advantages for thicker uveal melanomas (over 8 mm) due to its unique physical properties, including a rapid dose fall-off that protects critical structures like the retina and optic nerve. Proton therapy may have benefits in tumor control for ocular melanomas given its increased relative biological effectiveness relative to photon therapy for these typically more radioresistant melanomas. Proton therapy may also hold special value for uveal melanomas in close proximity to the optic nerve, as patients are at high risk of visual toxicities with brachytherapy. The review discusses the efficacy of proton therapy across small, medium, and large tumors, along with strategies for improving patient survival through combined systemic therapy. Additionally, the potential of ocular reirradiation with proton therapy is addressed. Conclusions: Proton therapy is an effective treatment for uveal melanoma. It offers advantages over brachytherapy for large tumors, tumors that are close to the optic nerve or insertion of extra-ocular muscles.

13 January 2023 in Current Oncology
Verified
Journal Article
Open access
PDF file
CACamille Hardy Abeloos
Camille Hardy Abeloos
JPJuhi Purswani
Juhi Purswani
PGPaulina Galavis
Paulina Galavis
AMAllison McCarthy
Allison McCarthy
CHChristine Hitchen
Christine Hitchen
NGNaamit K. Gerber
Naamit K. Gerber
Breast re-irradiation (reRT) after breast-conserving surgery (BCS) using external beam radiation is an increasingly used salvage approach for women presenting with recurrent or new primary breast cancer. However, radiation technique, dose and fractionation as well as eligibility criteria differ between studies. There is also limited data on efficacy and safety of external beam hypofractionation and accelerated partial-breast irradiation (APBI) regimens. This paper reviews existing retrospective and prospective data for breast reRT after BCS, APBI reRT outcomes and delivery at our institution and the need for a randomized controlled trial using shorter courses of radiation to better define patient selection for different reRT fractionation regimens.