Background: The increased use of wearable sensor technology has highlighted the potential for remote telehealth services such as rehabilitation. Telehealth services incorporating wearable sensors are most likely to appeal to the older adult population in remote and rural areas, who may struggle with long commutes to clinics. However, the usability of such systems often discourages patients from adopting these services. Objective: This study aimed to understand the usability factors that most influence whether an older adult will decide to continue using a wearable device. Methods: Older adults across 4 different regions (Northern Ireland, Ireland, Sweden, and Finland) wore an activity tracker for 7 days under a free-living environment protocol. In total, 4 surveys were administered, and biometrics were measured by the researchers before the trial began. At the end of the trial period, the researchers administered 2 further surveys to gain insights into the perceived usability of the wearable device. These were the standardized System Usability Scale (SUS) and a custom usability questionnaire designed by the research team. Statistical analyses were performed to identify the key factors that affect participants’ intention to continue using the wearable device in the future. Machine learning classifiers were used to provide an early prediction of the intention to continue using the wearable device. Results: The study was conducted with older adult volunteers (N=65; mean age 70.52, SD 5.65 years) wearing a Xiaomi Mi Band 3 activity tracker for 7 days in a free-living environment. The results from the SUS survey showed no notable difference in perceived system usability regardless of region, sex, or age, eliminating the notion that usability perception differs based on geographical location, sex, or deviation in participants’ age. There was also no statistically significant difference in SUS score between participants who had previously owned a wearable device and those who wore 1 or 2 devices during the trial. The bespoke usability questionnaire determined that the 2 most important factors that influenced an intention to continue device use in an older adult cohort were device comfort (τ=0.34) and whether the device was fit for purpose (τ=0.34). A computational model providing an early identifier of intention to continue device use was developed using these 2 features. Random forest classifiers were shown to provide the highest predictive performance (80% accuracy). After including the top 8 ranked questions from the bespoke questionnaire as features of our model, the accuracy increased to 88%. Conclusions: This study concludes that comfort and accuracy are the 2 main influencing factors in sustaining wearable device use. This study suggests that the reported factors influencing usability are transferable to other wearable sensor systems. Future work will aim to test this hypothesis using the same methodology on a cohort using other wearable technologies.
Portable inertial measurement units (IMUs) are beginning to be used in human motion analysis. These devices can be useful for the evaluation of spinal mobility in individuals with axial spondyloarthritis (axSpA). The objectives of this study were to assess (a) concurrent criterion validity in individuals with axSpA by comparing spinal mobility measured by an IMU sensor-based system vs. optical motion capture as the reference standard; (b) discriminant validity comparing mobility with healthy volunteers; (c) construct validity by comparing mobility results with relevant outcome measures. A total of 70 participants with axSpA and 20 healthy controls were included. Individuals with axSpA completed function and activity questionnaires, and their mobility was measured using conventional metrology for axSpA, an optical motion capture system, and an IMU sensor-based system. The UCOASMI, a metrology index based on measures obtained by motion capture, and the IUCOASMI, the same index using IMU measures, were also calculated. Descriptive and inferential analyses were conducted to show the relationships between outcome measures. There was excellent agreement (ICC > 0.90) between both systems and a significant correlation between the IUCOASMI and conventional metrology (r = 0.91), activity (r = 0.40), function (r = 0.62), quality of life (r = 0.55) and structural change (r = 0.76). This study demonstrates the validity of an IMU system to evaluate spinal mobility in axSpA. These systems are more feasible than optical motion capture systems, and they could be useful in clinical practice.
The increased use of sensor technology has been crucial in releasing the potential for remote rehabilitation. However, it is vital that human factors, that have potential to affect real-world use, are fully considered before sensors are adopted into remote rehabilitation practice. The smart sensor devices for rehabilitation and connected health (SENDoc) project assesses the human factors associated with sensors for remote rehabilitation of elders in the Northern Periphery of Europe. This article conducts a literature review of human factors and puts forward an objective scoring system to evaluate the feasibility of balance assessment technology for adaption into remote rehabilitation settings. The main factors that must be considered are: Deployment constraints, usability, comfort and accuracy. This article shows that improving accuracy, reliability and validity is the main goal of research focusing on developing novel balance assessment technology. However, other aspects of usability related to human factors such as practicality, comfort and ease of use need further consideration by researchers to help advance the technology to a state where it can be applied in remote rehabilitation settings.
The objectives of this study were to evaluate the reliability of wearable inertial motion unit (IMU) sensors in measuring spinal range of motion under supervised and unsupervised conditions in both laboratory and ambulatory settings. A secondary aim of the study was to evaluate the reliability of composite IMU metrology scores (IMU-ASMI (Amb)). Forty people with axSpA participated in this clinical measurement study. Participant spinal mobility was assessed by conventional metrology (Bath Ankylosing Spondylitis Metrology Index, linear version—BASMILin) and by a wireless IMU sensor-based system which measured lumbar flexion-extension, lateral flexion and rotation. Each sensor-based movement test was converted to a normalized index and used to calculate IMU-ASMI (Amb) scores. Test-retest reliability was evaluated using intra-class correlation coefficients (ICC). There was good to excellent agreement for all spinal range of movements (ICC > 0.85) and IMU-ASMI (Amb) scores (ICC > 0.87) across all conditions. Correlations between IMU-ASMI (Amb) scores and conventional metrology were strong (Pearson correlation ≥ 0.85). An IMU sensor-based system is a reliable way of measuring spinal lumbar mobility in axSpA under supervised and unsupervised conditions. While not a replacement for established clinical measures, composite IMU-ASMI (Amb) scores may be reliably used as a proxy measure of spinal mobility.
Stress is the body's response to an unusual situation. While it can be beneficial to a certain extent, in large amounts, it can be adverse. This paper proposes a methodology for detecting psychophysiological stress using infrared thermography, deep learning and explainable artificial intelligence. The Trier Social Stress Test protocol was used to induce psychophysiological stress in 58 university students, and thermographic images were collected during this time. Subsequently, the facial and hand areas were automatically segmented. This information was used to train a convolutional neural network to detect psychophysiological stress. Similarly, the Grad-CAM method was implemented to identify which areas of the face or hands contributed to the classification. Finally, the computational complexity of the proposal was evaluated. The results demonstrate that stress detection can be achieved with 99.5% accuracy, 98.3% precision, 98% recall and 98% F1-Score. Regarding the Grad-CAM results, it was observed that both areas, the hand and facial areas, tend to contribute more to classification in women than in men. The computational complexity analysis of the model indicates that it used 480.371MFLOPS, 11.569 MPARAMS and an average training time of 150.82 seconds. Based on this, it is concluded that infrared thermography is a technology that can aid in the detection of stress, and when combined with explainable artificial intelligence techniques, it enables users to understand the basis for their decisions, specifically which areas of the face and hands are affected.
Dementia is a series of neurodegenerative disorders that affect 1 in 4 people over the age of 80 and can greatly reduce the quality of life of those afflicted. Alzheimer’s disease (AD) is the most common variation, accounting for roughly 60% of cases. The current financial cost of these diseases is an estimated $1.3 trillion per year. While treatments are available to help patients maintain their mental function and slow disease progression, many of those with AD are asymptomatic in the early stages, resulting in late diagnosis. The addition of the routine testing needed for an effective level of early diagnosis would put a costly burden on both patients and healthcare systems. This research proposes a novel framework for the modelling of dementia, designed for deployment in edge hardware. This work extracts a wide variety of thoroughly researched Electroencephalogram (EEG) features, and through extensive feature selection, model testing, tuning, and edge optimization, we propose two novel Long Short-Term Memory (LSTM) neural networks. The first, uses 4 EEG sensors and can classify AD and Frontotemporal Dementia from cognitively normal (CN) subjects. The second, requires 3 EEG sensors and can classify AD from CN subjects. This is achieved with optimisation that reduces the model size by 83×, latency by 3.7×, and performs with an accuracy of 98%. Comparative analysis with existing research shows this performance exceeds current less portable techniques. The deployment of this model in edge hardware could aid in routine testing, providing earlier diagnosis of dementia, reducing the strain on healthcare systems, and increasing the quality of life for those afflicted with the disease.