Md Mohiuddin Soliman

Mr. Md Mohiuddin Soliman

The National University of Malaysia (UKM)
+2
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 May 2021 in Sensors
Verified
Journal Article
Open access
PDF file
Md Mohiuddin SolimanMd Mohiuddin Soliman
Md Mohiuddin Soliman
Muhammad E. H. ChowdhuryMuhammad E. H. Chowdhury
Muhammad E. H. Chowdhury
AKAmith Khandakar
Amith Khandakar
MIMohammad Tariqul Islam
Mohammad Tariqul Islam
YQYazan Qiblawey
Yazan Qiblawey
ENErfan Zal Nezhad
Erfan Zal Nezhad
Implantable antennas are mandatory to transfer data from implants to the external world wirelessly. Smart implants can be used to monitor and diagnose the medical conditions of the patient. The dispersion of the dielectric constant of the tissues and variability of organ structures of the human body absorb most of the antenna radiation. Consequently, implanting an antenna inside the human body is a very challenging task. The design of the antenna is required to fulfill several conditions, such as miniaturization of the antenna dimension, biocompatibility, the satisfaction of the Specific Absorption Rate (SAR), and efficient radiation characteristics. The asymmetric hostile human body environment makes implant antenna technology even more challenging. This paper aims to summarize the recent implantable antenna technologies for medical applications and highlight the major research challenges. Also, it highlights the required technology and the frequency band, and the factors that can affect the radio frequency propagation through human body tissue. It includes a demonstration of a parametric literature investigation of the implantable antennas developed. Furthermore, fabrication and implantation methods of the antenna inside the human body are summarized elaborately. This extensive summary of the medical implantable antenna technology will help in understanding the prospects and challenges of this technology.

13 October 2022 in Polymers
Verified
Journal Article
Open access
PDF file
Md Mohiuddin SolimanMd Mohiuddin Soliman
Md Mohiuddin Soliman
Muhammad E. H. ChowdhuryMuhammad E. H. Chowdhury
Muhammad E. H. Chowdhury
MIMohammad Tariqul Islam
Mohammad Tariqul Islam
FMFarayi Musharavati
Farayi Musharavati
MNMohammad Nabil
Mohammad Nabil
FAFarhan Fuad Abir
Farhan Fuad Abir
Total hip replacement (THR) is a common orthopedic surgery technique that helps thousands of individuals to live normal lives each year. A hip replacement replaces the shattered cartilage and bone with an implant. Most hip implants fail after 10–15 years. The material selection for the total hip implant systems is a major research field since it affects the mechanical and clinical performance of it. Stress shielding due to excessive contact stress, implant dislocation due to a large deformation, aseptic implant loosening due to the particle propagation of wear debris, decreased bone remodeling density due to the stress shielding, and adverse tissue responses due to material wear debris all contribute to the failure of hip implants. Recent research shows that pre-clinical computational finite element analysis (FEA) can be used to estimate four mechanical performance parameters of hip implants which are connected with distinct biomaterials: von Mises stress and deformation, micromotion, wear estimates, and implant fatigue. In vitro, in vivo, and clinical stages are utilized to determine the hip implant biocompatibility and the unfavorable local tissue reactions to different biomaterials during the implementation phase. This research summarizes and analyses the performance of the different biomaterials that are employed in total hip implant systems in the pre-clinical stage using FEA, as well as their performances in in vitro, in vivo, and in clinical studies, which will help researchers in gaining a better understanding of the prospects and challenges in this field.

9 May 2022 in IEEE Access
Verified
Journal Article
Open access
Tawsifur RahmanTawsifur Rahman
Tawsifur Rahman
AKAmith Khandakar
Amith Khandakar
KIKhandaker Reajul Islam
Khandaker Reajul Islam
Md Mohiuddin SolimanMd Mohiuddin Soliman
Md Mohiuddin Soliman
MIMohammad Tariqul Islam
Mohammad Tariqul Islam
Muhammad E. H. ChowdhuryMuhammad E. H. Chowdhury
Muhammad E. H. Chowdhury
Radiographic images are commonly used to detect aseptic loosening of the hip implant in patients with total hip replacement (THR) surgeries. These techniques of manual assessment by medical professionals can suffer from the drawback of low accuracy, poor inter-observer reliability, and delays due to the unavailability of experienced clinicians. Thus, the paper provides a reliable Deep Convolutional Neural Networks (DCNNs) based novel stacking approach (HipXNet) for detecting loosening of the hip implant using X-ray images. Two major investigations were done in this study. Firstly, the performance of four different state-of-the-art object detection YOLOv5 models was evaluated to detect the implant region from the hip X-ray images. Secondly, the study developed a stacking classifier using three different Convolutional neural networks (CNN) models to classify aseptic hip loosening and compared the performance with eight different state-of-the-art CNN networks. Moreover, one publicly accessible dataset with two sub-sets was created for these two experiments, where 200 hip implant X-ray images were collected and annotated by two expert radiologists for implant detection and 206 hip implant X-ray images were collected for loosening detection. YOLOv5m model outperformed the other variants of YOLOv5 to detect the implant region with the precision, recall, mean average precision (mAP) 0.5 , mAP 0.5–0.95 of 100%, 100%, 100%, and 87.8%, respectively. Densenet201 CNN model outperformed other CNN models with the accuracy, precision, sensitivity, F1 score, and specificity of 94.66%, 94.66%, 94.66%, 94.66%, and 94.5%, respectively while the stacking technique with Random Forest meta learner classifier produced the best performance with the accuracy, precision, sensitivity, F1 score and specificity of 96.11%, 96.42%, 96.42%, 96.42%, and 96.74% respectively for loosening detection. The reliability of the performance was confirmed by the popular Score-CAM visualization. This study can help in the early and fast identification of hip implant loosening with the help of simple X-ray images and computed aided diagnosis.

9 February 2023 in Materials
Verified
Journal Article
Open access
PDF file
Md Mohiuddin SolimanMd Mohiuddin Soliman
Md Mohiuddin Soliman
Muhammad E. H. ChowdhuryMuhammad E. H. Chowdhury
Muhammad E. H. Chowdhury
MIMohammad Tariqul Islam
Mohammad Tariqul Islam
FMFarayi Musharavati
Farayi Musharavati
Sakib MahmudSakib Mahmud
Sakib Mahmud
ENErfan Zal Nezhad
Erfan Zal Nezhad
With an expectation of an increased number of revision surgeries and patients receiving orthopedic implants in the coming years, the focus of joint replacement research needs to be on improving the mechanical properties of implants. Head-stem trunnion fixation provides superior load support and implant stability. Fretting wear is formed at the trunnion because of the dynamic load activities of patients, and this eventually causes the total hip implant system to fail. To optimize the design, multiple experiments with various trunnion geometries have been performed by researchers to examine the wear rate and associated mechanical performance characteristics of the existing head-stem trunnion. The objective of this work is to quantify and evaluate the performance parameters of smooth and novel spiral head-stem trunnion types under dynamic loading situations. This study proposes a finite element method for estimating head-stem trunnion performance characteristics, namely contact pressure and sliding distance, for both trunnion types under walking and jogging dynamic loading conditions. The wear rate for both trunnion types was computed using the Archard wear model for a standard number of gait cycles. The experimental results indicated that the spiral trunnion with a uniform contact pressure distribution achieved more fixation than the smooth trunnion. However, the average contact pressure distribution was nearly the same for both trunnion types. The maximum and average sliding distances were both shorter for the spiral trunnion; hence, the summed sliding distance was approximately 10% shorter for spiral trunnions than that of the smooth trunnion over a complete gait cycle. Owing to a lower sliding ability, hip implants with spiral trunnions achieved more stability than those with smooth trunnions. The anticipated wear rate for spiral trunnions was 0.039 mm3, which was approximately 10% lower than the smooth trunnion wear rate of 0.048 mm3 per million loading cycles. The spiral trunnion achieved superior fixation stability with a shorter sliding distance and a lower wear rate than the smooth trunnion; therefore, the spiral trunnion can be recommended for future hip implant systems.

1 February 2020
Verified
Conference Paper
Closed access
MMMohamed Yusuf Mohamed
Mohamed Yusuf Mohamed
ADAbsir Mohamud Dini
Absir Mohamud Dini
Md Mohiuddin SolimanMd Mohiuddin Soliman
Md Mohiuddin Soliman
AIAbu Zafar Md. Imran
Abu Zafar Md. Imran
In wireless technology, the use of microstrip patch antenna (MPA) has greatly expanded due to its low cost, low profile and ease of manufacturing in the circuit boards. But in some case poor performance such as low capacity handling, narrow bandwidth, low gain limit their application. The purpose of this work is to solve such limit through designing an efficient $2\times 2$ MPA array according to 5G applications. In designing antenna, Foam is used as substrate material having substrate height $\text{Hs}=1.5$ mm and inset feeding technique used to feed the antenna. The recommended $2\times 2$ antenna array exhibited quality performance having the bandwidth, return loss, realized gain, VSWR and antenna efficiency are 4 GHz, −74 dB, 23.8 dBi, 1.01 and 99% at frequency band 28GHz respectively. After analyzing the previous works, it can be seen that the intended antenna array showed efficient performance than the previous works and covered all lacking's according to 5G applications.

1 December 2019
Verified
Conference Paper
Closed access
Md Mohiuddin SolimanMd Mohiuddin Soliman
Md Mohiuddin Soliman
MHMohammad Lutful Hakim
Mohammad Lutful Hakim
MUMohammed Jashim Uddin
Mohammed Jashim Uddin
MFMuhammad Mostafa Amir Faisal
Muhammad Mostafa Amir Faisal
ARAtikur Rahaman
Atikur Rahaman
This paper has found out optimized value of design parameters of microstrip patch antenna (MPA) at 28 GHz and 38 GHz for 5G applications. Three design parameters namely: substrate element, substrate height and feeding technique have significant effect on antenna performance. If these are not suitably elected, the 5G requirements won't be covered. This work has found out the optimized value of substrate element, substrate height and feeding technique as design parameters for designing MPA at 28 GHz and 38 GHz which fulfill the 5G requirements. In addition, a comparative observation of antenna performance is done among the antennas which are designed based on these three design parameter values. Foam as substrate element, substrate height 0.5 mm and quarter wave transformer feeding technique have been found as the best performance provider at 28 GHz and 38 GHz frequency bands as per 5G requirement. In conclusion, Single element Antenna is designed on 28 GHz and 38 GHz using aforementioned best performance provider design parameter values.