Erfan Zal Nezhad

Erfan Zal Nezhad


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 May 2021 in Sensors
Verified
Journal Article
Open access
PDF file
Md Mohiuddin SolimanMd Mohiuddin Soliman
Md Mohiuddin Soliman
Muhammad E. H. ChowdhuryMuhammad E. H. Chowdhury
Muhammad E. H. Chowdhury
AKAmith Khandakar
Amith Khandakar
MIMohammad Tariqul Islam
Mohammad Tariqul Islam
YQYazan Qiblawey
Yazan Qiblawey
ENErfan Zal Nezhad
Erfan Zal Nezhad
Implantable antennas are mandatory to transfer data from implants to the external world wirelessly. Smart implants can be used to monitor and diagnose the medical conditions of the patient. The dispersion of the dielectric constant of the tissues and variability of organ structures of the human body absorb most of the antenna radiation. Consequently, implanting an antenna inside the human body is a very challenging task. The design of the antenna is required to fulfill several conditions, such as miniaturization of the antenna dimension, biocompatibility, the satisfaction of the Specific Absorption Rate (SAR), and efficient radiation characteristics. The asymmetric hostile human body environment makes implant antenna technology even more challenging. This paper aims to summarize the recent implantable antenna technologies for medical applications and highlight the major research challenges. Also, it highlights the required technology and the frequency band, and the factors that can affect the radio frequency propagation through human body tissue. It includes a demonstration of a parametric literature investigation of the implantable antennas developed. Furthermore, fabrication and implantation methods of the antenna inside the human body are summarized elaborately. This extensive summary of the medical implantable antenna technology will help in understanding the prospects and challenges of this technology.

30 June 2020 in Nanomaterials
Verified
Journal Article
Open access
PDF file
XCXin Chen
Xin Chen
HLHui Li
Hui Li
JXJianzhou Xu
Jianzhou Xu
FJFadi Jaber
Fadi Jaber
FMFarayi Musharavati
Farayi Musharavati
JLJunxing Liu
Junxing Liu
In this study, we synthesized binder-free NiCo2O4@NiCo2O4 nanostructured materials on nickel foam (NF) by combined hydrothermal and cyclic voltammetry deposition techniques followed by calcination at 350 °C to attain high-performance supercapacitors. The hierarchical porous NiCo2O4@NiCo2O4 structure, facilitating faster mass transport, exhibited good cycling stability of 83.6% after 5000 cycles and outstanding specific capacitance of 1398.73 F g−1 at the current density of 2 A·g−1, signifying its potential for energy storage applications. A solid-state supercapacitor was fabricated with the NiCo2O4@NiCo2O4 on NF as the positive electrode and the active carbon (AC) was deposited on NF as the negative electrode, delivering a high energy density of 46.46 Wh kg−1 at the power density of 269.77 W kg−1. This outstanding performance was attributed to its layered morphological characteristics. This study explored the potential application of cyclic voltammetry depositions in preparing binder-free NiCo2O4@NiCo2O4 materials with more uniform architecture for energy storage, in contrast to the traditional galvanostatic deposition methods.

3 November 2020 in Scientific Reports
Verified
Journal Article
Open access
PDF file
XCXin Chen
Xin Chen
RXRui Xie
Rui Xie
HLHui Li
Hui Li
FJF. Jaber
F. Jaber
FMF. Musharavati
F. Musharavati
KHK. N. Hui
K. N. Hui
In this work, nickel cobaltite (NiCo2O4) nanosheets with a porous structure were fabricated on nickel foam as a working electrode for supercapacitor applications. The nanosheets were fabricated by electrochemical deposition of nickel–cobalt hydroxide on the nickel foam substrate at ambient temperature in a three-electrode cell followed by annealing at 300 °C to transform the coating into a porous NiCo2O4nanosheet. Field emission scanning electron microscopy and transmission electron microscopy revealed a three-dimensional mesoporous structure, which facilitates ion transport and electronic conduction for fast redox reactions. For one cycle, the NiCo2O4electrodeposited nickel foam has a high specific capacitance (1734.9 F g−1) at a current density (CD) of 2 A g−1. The electrode capacitance decreased by only approximately 12.7% after 3500 cycles at a CD of 30 A g−1. Moreover, a solid-state asymmetric supercapacitor (ASC) was built utilising the NiCo2O4nanosheets, carbon nanotubes, and a polyvinyl alcohol-potassium hydroxide gel as the anode, cathode, and solid-state electrolyte, respectively. The ASC displayed great electrochemical properties with a 42.25 W h kg−1energy density at a power density of 298.79 W kg−1.

13 October 2022 in Polymers
Verified
Journal Article
Open access
PDF file
Md Mohiuddin SolimanMd Mohiuddin Soliman
Md Mohiuddin Soliman
Muhammad E. H. ChowdhuryMuhammad E. H. Chowdhury
Muhammad E. H. Chowdhury
MIMohammad Tariqul Islam
Mohammad Tariqul Islam
FMFarayi Musharavati
Farayi Musharavati
MNMohammad Nabil
Mohammad Nabil
FAFarhan Fuad Abir
Farhan Fuad Abir
Total hip replacement (THR) is a common orthopedic surgery technique that helps thousands of individuals to live normal lives each year. A hip replacement replaces the shattered cartilage and bone with an implant. Most hip implants fail after 10–15 years. The material selection for the total hip implant systems is a major research field since it affects the mechanical and clinical performance of it. Stress shielding due to excessive contact stress, implant dislocation due to a large deformation, aseptic implant loosening due to the particle propagation of wear debris, decreased bone remodeling density due to the stress shielding, and adverse tissue responses due to material wear debris all contribute to the failure of hip implants. Recent research shows that pre-clinical computational finite element analysis (FEA) can be used to estimate four mechanical performance parameters of hip implants which are connected with distinct biomaterials: von Mises stress and deformation, micromotion, wear estimates, and implant fatigue. In vitro, in vivo, and clinical stages are utilized to determine the hip implant biocompatibility and the unfavorable local tissue reactions to different biomaterials during the implementation phase. This research summarizes and analyses the performance of the different biomaterials that are employed in total hip implant systems in the pre-clinical stage using FEA, as well as their performances in in vitro, in vivo, and in clinical studies, which will help researchers in gaining a better understanding of the prospects and challenges in this field.

23 March 2020 in Nanomaterials
Verified
Journal Article
Open access
PDF file
CXChen Xin
Chen Xin
LALi Ang
Li Ang
FMFarayi Musharavati
Farayi Musharavati
FJFadi Jaber
Fadi Jaber
HLHui Li
Hui Li
KHK.N. Hui
K.N. Hui
In this study, to fabricate a non-binder electrode, we grew nickel–cobalt sulfide (NCS) nanotubes (NTs) on a Ni foam substrate using a hydrothermal method through a two-step approach, namely in situ growth and an anion-exchange reaction. This was followed by the electrodeposition of double-layered nickel-cobalt hydroxide (NCOH) over a nanotube-coated substrate to fabricate NCOH core-shell nanotubes. The final product is called NCS@NCOH herein. Structural and morphological analyses of the synthesized electrode materials were conducted via SEM and XRD. Different electrodeposition times were selected, including 10, 20, 40, and 80 s. The results indicate that the NCSNTs electrodeposited with NCOH nanosheets for 40 s have the highest specific capacitance (SC), cycling stability (2105 Fg−1 at a current density of 2 Ag−1), and capacitance retention (65.1% after 3,000 cycles), in comparison with those electrodeposited for 10, 20, and 80 s. Furthermore, for practical applications, a device with negative and positive electrodes made of active carbon and NCS@NCOH was fabricated, achieving a high-energy density of 23.73 Whkg−1 at a power density of 400 Wkg−1.

25 June 2021 in Nanomaterials
Verified
Journal Article
Open access
PDF file
PLPeiqi Li
Peiqi Li
JLJunxing Liu
Junxing Liu
SHSungwun Her
Sungwun Her
ENErfan Zal Nezhad
Erfan Zal Nezhad
SLSeungmin Lim
Seungmin Lim
SBSungchul Bae
Sungchul Bae
In this study, a graphene oxide nanoribbons–functionalized carbon nanotubes–graphene oxide (GNFG) complex was hydrothermally synthesized as a nanomaterial for reinforcing cementitious composites, using a modified Hummers’ method. Three types of components existed in the GNFG: Type I, the functionalized carbon nanotubes–graphene oxide nanoribbons (FCNTs–GNR); and types II and III are graphene oxide (GO) and functionalized carbon nanotubes (FCNTs), respectively, which exist independently. The dispersivity of GNFG and its effects on the mechanical properties, hydration process, and microstructures of cement pastes were evaluated, and the results were compared with those using cement pastes incorporating other typical carbon nanomaterials. The results demonstrated that dispersion of GNFG in aqueous solutions was superior to that of the CNTs, FCNTs, and GO/FCNTs mixture. Furthermore, the highly-dispersed GNFG (0.05 wt.%) improved the mechanical properties of the cement paste after 28 days of hydration and promoted the hydration of cement compared to CNTs, GO, and GO/FCNTs mixture (0.05 wt.%). The results in this study validated the feasibility of using GNFG with enhanced dispersion as a new nano-reinforcing agent for various cementitious systems.