Farayi Musharavati

Dr. Farayi Musharavati

Qatar University
orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2022 in Chemosphere
Verified
Journal Article
Closed access
FMFarayi Musharavati
Farayi Musharavati
AKAlireza Khoshnevisan
Alireza Khoshnevisan
SASeyed Mojtaba Alirahmi
Seyed Mojtaba Alirahmi
PAPouria Ahmadi
Pouria Ahmadi
SKShoaib Khanmohammadi
Shoaib Khanmohammadi

17 May 2021 in Diagnostics
Verified
Journal Article
Open access
PDF file
YQYazan Qiblawey
Yazan Qiblawey
ATAnas Tahir
Anas Tahir
Muhammad E. H. ChowdhuryMuhammad E. H. Chowdhury
Muhammad E. H. Chowdhury
AKAmith Khandakar
Amith Khandakar
Serkan KiranyazSerkan Kiranyaz
Serkan Kiranyaz
MAMohamed Arselene Ayari
Mohamed Arselene Ayari
Detecting COVID-19 at an early stage is essential to reduce the mortality risk of the patients. In this study, a cascaded system is proposed to segment the lung, detect, localize, and quantify COVID-19 infections from computed tomography images. An extensive set of experiments were performed using Encoder–Decoder Convolutional Neural Networks (ED-CNNs), UNet, and Feature Pyramid Network (FPN), with different backbone (encoder) structures using the variants of DenseNet and ResNet. The conducted experiments for lung region segmentation showed a Dice Similarity Coefficient (DSC) of 97.19% and Intersection over Union (IoU) of 95.10% using U-Net model with the DenseNet 161 encoder. Furthermore, the proposed system achieved an elegant performance for COVID-19 infection segmentation with a DSC of 94.13% and IoU of 91.85% using the FPN with DenseNet201 encoder. The proposed system can reliably localize infections of various shapes and sizes, especially small infection regions, which are rarely considered in recent studies. Moreover, the proposed system achieved high COVID-19 detection performance with 99.64% sensitivity and 98.72% specificity. Finally, the system was able to discriminate between different severity levels of COVID-19 infection over a dataset of 1110 subjects with sensitivity values of 98.3%, 71.2%, 77.8%, and 100% for mild, moderate, severe, and critical, respectively.

2 May 2021 in Sensors
Verified
Journal Article
Open access
PDF file
Md Mohiuddin SolimanMd Mohiuddin Soliman
Md Mohiuddin Soliman
Muhammad E. H. ChowdhuryMuhammad E. H. Chowdhury
Muhammad E. H. Chowdhury
AKAmith Khandakar
Amith Khandakar
MIMohammad Tariqul Islam
Mohammad Tariqul Islam
YQYazan Qiblawey
Yazan Qiblawey
ENErfan Zal Nezhad
Erfan Zal Nezhad
Implantable antennas are mandatory to transfer data from implants to the external world wirelessly. Smart implants can be used to monitor and diagnose the medical conditions of the patient. The dispersion of the dielectric constant of the tissues and variability of organ structures of the human body absorb most of the antenna radiation. Consequently, implanting an antenna inside the human body is a very challenging task. The design of the antenna is required to fulfill several conditions, such as miniaturization of the antenna dimension, biocompatibility, the satisfaction of the Specific Absorption Rate (SAR), and efficient radiation characteristics. The asymmetric hostile human body environment makes implant antenna technology even more challenging. This paper aims to summarize the recent implantable antenna technologies for medical applications and highlight the major research challenges. Also, it highlights the required technology and the frequency band, and the factors that can affect the radio frequency propagation through human body tissue. It includes a demonstration of a parametric literature investigation of the implantable antennas developed. Furthermore, fabrication and implantation methods of the antenna inside the human body are summarized elaborately. This extensive summary of the medical implantable antenna technology will help in understanding the prospects and challenges of this technology.

1 December 2020 in Structures
Verified
Journal Article
Closed access
HTHossein Taghipoor
Hossein Taghipoor
AEArameh Eyvazian
Arameh Eyvazian
FMFarayi Musharavati
Farayi Musharavati
Tamer SebaeyTamer Sebaey
Tamer Sebaey
AGAhmad Ghiaskar
Ahmad Ghiaskar

25 January 2022 in Sensors
Verified
Journal Article
Open access
PDF file
Sakib MahmudSakib Mahmud
Sakib Mahmud
NINabil Ibtehaz
Nabil Ibtehaz
AKAmith Khandakar
Amith Khandakar
ATAnas Tahir
Anas Tahir
Tawsifur RahmanTawsifur Rahman
Tawsifur Rahman
Muhammad E. H. ChowdhuryMuhammad E. H. Chowdhury
Muhammad E. H. Chowdhury
Cardiovascular diseases are the most common causes of death around the world. To detect and treat heart-related diseases, continuous blood pressure (BP) monitoring along with many other parameters are required. Several invasive and non-invasive methods have been developed for this purpose. Most existing methods used in hospitals for continuous monitoring of BP are invasive. On the contrary, cuff-based BP monitoring methods, which can predict systolic blood pressure (SBP) and diastolic blood pressure (DBP), cannot be used for continuous monitoring. Several studies attempted to predict BP from non-invasively collectible signals such as photoplethysmograms (PPG) and electrocardiograms (ECG), which can be used for continuous monitoring. In this study, we explored the applicability of autoencoders in predicting BP from PPG and ECG signals. The investigation was carried out on 12,000 instances of 942 patients of the MIMIC-II dataset, and it was found that a very shallow, one-dimensional autoencoder can extract the relevant features to predict the SBP and DBP with state-of-the-art performance on a very large dataset. An independent test set from a portion of the MIMIC-II dataset provided a mean absolute error (MAE) of 2.333 and 0.713 for SBP and DBP, respectively. On an external dataset of 40 subjects, the model trained on the MIMIC-II dataset provided an MAE of 2.728 and 1.166 for SBP and DBP, respectively. For both the cases, the results met British Hypertension Society (BHS) Grade A and surpassed the studies from the current literature.