Jesse Fine

Mr. Jesse Fine


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 April 2021 in Biosensors
Verified
Journal Article
Open access
PDF file
JFJesse Fine
Jesse Fine
KBKimberly Branan
Kimberly Branan
ARAndres J. Rodriguez
Andres J. Rodriguez
TBTananant Boonya-Ananta
Tananant Boonya-Ananta
AJAjmal
Ajmal
GCGerard Cote
Gerard Cote
Photoplethysmography (PPG) is a low-cost, noninvasive optical technique that uses change in light transmission with changes in blood volume within tissue to provide information for cardiovascular health and fitness. As remote health and wearable medical devices become more prevalent, PPG devices are being developed as part of wearable systems to monitor parameters such as heart rate (HR) that do not require complex analysis of the PPG waveform. However, complex analyses of the PPG waveform yield valuable clinical information, such as: blood pressure, respiratory information, sympathetic nervous system activity, and heart rate variability. Systems aiming to derive such complex parameters do not always account for realistic sources of noise, as testing is performed within controlled parameter spaces. A wearable monitoring tool to be used beyond fitness and heart rate must account for noise sources originating from individual patient variations (e.g., skin tone, obesity, age, and gender), physiology (e.g., respiration, venous pulsation, body site of measurement, and body temperature), and external perturbations of the device itself (e.g., motion artifact, ambient light, and applied pressure to the skin). Here, we present a comprehensive review of the literature that aims to summarize these noise sources for future PPG device development for use in health monitoring.

29 March 2022 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
ARAndres J. Rodriguez
Andres J. Rodriguez
MBMel Tananant Boonya-Ananta
Mel Tananant Boonya-Ananta
MGMariacarla Gonzalez
Mariacarla Gonzalez
Vinh Nguyen Du LeVinh Nguyen Du Le
Vinh Nguyen Du Le
JFJesse Fine
Jesse Fine
Jessica RamellaJessica Ramella
Jessica Ramella
Significance: Obesity is a worldwide epidemic contributing directly to several cardiovascular risk factors including hypertension and type 2 diabetes. Wearable devices are becoming better at quantifying biomarkers relevant for the management of health and fitness. Unfortunately, both anecdotal evidence and recent studies indicate that some wearables have higher levels of error when utilized by populations with darker skin tones and high body mass index (BMI). There is an urgent need for a better evaluation of the limits of wearable health technologies when used by obese individuals. Aims: (1) To review the current know-how on changes due to obesity in the skin epidermis, dermis, and subcutis that could affect the skin optical properties; (2) for the green wavelength range, to evaluate the difference in absorption and scattering coefficients from the abdominal skin between individuals with and without elevated BMI. The changes include alterations in layer thickness and cell size, as well as significant differences in chromophores and scatterer content, e.g., water, hemoglobin, collagen, and lipids. Approach: We have summarized literature pertaining to changes in skin and its components in obesity and report the results of our search using articles published between years 1971 and 2020. A linear model was used to demonstrate the absorption and reduced scattering coefficient of the abdominal skin of individuals with and without elevated BMI in the green wavelength range (530 to 550 nm) that is typically found in most wearables. Results: The general trends indicate a decrease in absorption for both dermis and subcutis and an increase in reduced scattering for both epidermis and dermis. At 544-nm wavelength, a typical wavelength used for photoplethysmography (PPG), the absorption coefficient’s relative percentage difference between high and low BMI skin, was 49% in the subcutis, 19% in the dermis, and negligible in the epidermis, whereas the reduced scattering coefficient relative difference was 21%, 29%, and 165% respectively. Conclusions: These findings suggest that there could be significant errors in the output of optical devices used for monitoring health and fitness if changes due to obesity are not accounted for in their design.

4 August 2022 in Biosensors
Verified
Journal Article
Open access
PDF file
JFJesse Fine
Jesse Fine
MMMike Mcshane
Mike Mcshane
GCGerard Cote
Gerard Cote
CSChristopher G. Scully
Christopher G. Scully
Cardiovascular disease is the leading cause of death globally. To provide continuous monitoring of blood pressure (BP), a parameter which has shown to improve health outcomes when monitored closely, many groups are trying to measure blood pressure via noninvasive photoplethysmography (PPG). However, the PPG waveform is subject to variation as a function of patient-specific and device factors and thus a platform to enable the evaluation of these factors on the PPG waveform and subsequent hemodynamic parameter prediction would enable device development. Here, we present a computational workflow that combines Monte Carlo modeling (MC), gaussian combination, and additive noise to create synthetic dataset of volar fingertip PPG waveforms representative of a diverse cohort. First, MC is used to determine PPG amplitude across age, skin tone, and device wavelength. Then, gaussian combination generates accurate PPG waveforms, and signal processing enables data filtration and feature extraction. We improve the limitations of current synthetic PPG frameworks by enabling inclusion of physiological and anatomical effects from body site, skin tone, and age. We then show how the datasets can be used to examine effects of device characteristics such as wavelength, analog to digital converter specifications, filtering method, and feature extraction. Lastly, we demonstrate the use of this framework to show the insensitivity of a support vector machine predictive algorithm compared to a neural network and bagged trees algorithm.

3 May 2022 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
JFJesse Fine
Jesse Fine
MMMike Mcshane
Mike Mcshane
GCGerard Cote
Gerard Cote
Significance: Continuous glucose monitors (CGMs) are increasingly utilized as a way to provide healthcare to the over 10% of Americans that have diabetes. Fully insertable and optically transduced biosensors are poised to further improve CGMs by extending the device lifetime and reducing cost. However, optical modeling of light propagation in tissue is necessary to ascertain device performance. Aim: Monte Carlo modeling of photon transport through tissue was used to assess the luminescent output of a fully insertable glucose biosensor that uses a multimodal Förster resonance energy transfer competitive binding assay and a phosphorescence lifetime decay enzymatic assay. Approach: A Monte Carlo simulation framework of biosensor luminescence and tissue autofluorescence was built using MCmatlab. Simulations were first validated against previous research and then applied to predict the response of a biosensor in development. Results: Our results suggest that a diode within the safety standards for light illumination on the skin, with far-red excitation, allows the luminescent biosensor to yield emission strong enough to be detectable by a common photodiode. Conclusions: The computational model showed that the expected fluorescent power output of a near-infrared light actuated barcode was five orders of magnitude greater than a visible spectrum excited counterpart biosensor.

1 November 2022 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
JFJesse Fine
Jesse Fine
GCGerard Cote
Gerard Cote
MMMike Mcshane
Mike Mcshane
SignificanceInsertable optical continuous glucose monitors (CGMs) with wearable readers are a strong option for monitoring individuals with diabetes. However, a fully insertable CGM requires a small form factor while still delivering sufficient signal to be read through tissue by an external device. Previous work has suggested that a multimodal repeating unit (barcode) approach may meet these requirements, but the biosensor geometry must be optimized to meet performance criteria.AimThis work details in silico trials conducted to evaluate the geometry of a fully insertable multimodal optical biosensor with respect to both optical output and species diffusion in vivo.ApproachMonte Carlo modeling is used to evaluate the luminescent output of three presupposed biosensor designs based on size constraints for an injectable and logical placement of the bar code compartments. Specifically, the sensitivity of the luminescent output to displacement of the biosensor in the X and Y directions, overall size of the selected design, and size of an individual repeating unit are analyzed. Further, an experimentally validated multiphysics model is used to evaluate the diffusion and reaction of glucose and oxygen within the biosensor to estimate the occurrence of chemical crosstalk between the assay components.ResultsA stacked cylinder multimodal biosensor 4.4 mm in length with repeating units 0.36 mm in length was found to yield a greater luminescent output than the current “barcode” biosensor design. In addition, it was found that a biosensor with enzymatic elements does not significantly deplete glucose locally and thus does not impact the diffusion profile of glucose in adjacent compartments containing nonenzymatic assays.ConclusionsComputational modeling was used to design the geometry of a multimodal, insertable, and optical CGM to ensure that the optical output and chemical diffusion profile are sufficient for this device to function in vivo.