Gerard Cote

Prof. Gerard Cote

Texas A&M University
orcid

Research Focus & Metrics

Academic Career Length

33Years (1994-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 April 2021 in Biosensors
Verified
Journal Article
Open access
PDF file
JFJesse Fine
Jesse Fine
KBKimberly Branan
Kimberly Branan
ARAndres J. Rodriguez
Andres J. Rodriguez
TBTananant Boonya-Ananta
Tananant Boonya-Ananta
AJAjmal
Ajmal
GCGerard Cote
Gerard Cote
Photoplethysmography (PPG) is a low-cost, noninvasive optical technique that uses change in light transmission with changes in blood volume within tissue to provide information for cardiovascular health and fitness. As remote health and wearable medical devices become more prevalent, PPG devices are being developed as part of wearable systems to monitor parameters such as heart rate (HR) that do not require complex analysis of the PPG waveform. However, complex analyses of the PPG waveform yield valuable clinical information, such as: blood pressure, respiratory information, sympathetic nervous system activity, and heart rate variability. Systems aiming to derive such complex parameters do not always account for realistic sources of noise, as testing is performed within controlled parameter spaces. A wearable monitoring tool to be used beyond fitness and heart rate must account for noise sources originating from individual patient variations (e.g., skin tone, obesity, age, and gender), physiology (e.g., respiration, venous pulsation, body site of measurement, and body temperature), and external perturbations of the device itself (e.g., motion artifact, ambient light, and applied pressure to the skin). Here, we present a comprehensive review of the literature that aims to summarize these noise sources for future PPG device development for use in health monitoring.

1 January 2000 in Journal of Biomedical Optics
Verified
Journal Article
Closed access
RMRoger J. McNichols
Roger J. McNichols
GCGerard Cote
Gerard Cote
Recent technological advancements in the photonics industry have led to a resurgence of interest in optical glucose sensing and to realistic progress toward the development of an optical glucose sensor. Such a sensor has the potential to significantly improve the quality of life for the estimated 16 million diabetics in this country by making routine glucose measurements more convenient. Currently over 100 small companies and universities are working to develop noninvasive or minimally invasive glucose sensing technologies, and optical methods play a large role in these efforts. This article reviews many of the recent advances in optical glucose sensing including optical absorption spectroscopy, polarimetry, Raman spectroscopy, and fluorescent glucose sensing. In addition a review of calibration and data processing methods useful for optical techniques is presented.

20 May 2008 in Nano Letters
Verified
Journal Article
Closed access
ICI-Hsien Chou
I-Hsien Chou
MBMelodie Benford
Melodie Benford
HBHope T. Beier
Hope T. Beier
GCGerard Cote
Gerard Cote
MWMiao Wang
Miao Wang
TGTheresa A. Good
Theresa A. Good

1 January 2021 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
MOMengxing Ouyang
Mengxing Ouyang
DTDandan Tu
Dandan Tu
LTLin Tong
Lin Tong
MSMehenur Sarwar
Mehenur Sarwar
ABArvind Bhimaraj
Arvind Bhimaraj
DCDino Di Carlo
Dino Di Carlo

1 January 2002 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
JBJustin S. Baba
Justin S. Baba
JCJung-Rae Chung
Jung-Rae Chung
ADAimee H. DeLaughter
Aimee H. DeLaughter
BCBrent D. Cameron
Brent D. Cameron
GCGerard Cote
Gerard Cote
The high fatality rate associated with the late detection of skin cancer makes early detection crucial in preventing death. The current method for determining if a skin lesion is suspect to cancer is initially based on the patient’s and physician’s subjective observation of the skin lesion. Physicians use a set of parameters called the ABCD (asymmetry, border, color, diameter) rule to help facilitate diagnosis of potential cancerous lesions. Lesions that are suspicious then require a biopsy, which is a painful, invasive, and a time-consuming procedure. In an attempt to reduce the aforementioned undesirable elements currently associated with skin cancer diagnosis, a novel optical polarization-imaging system is described that has the potential to noninvasively detect cancerous lesions. The described system generates the full 16-element Mueller matrix in less than 70 s. The operation of the system was tested in transmission, specular reflection, and diffuse reflectance modes, using known samples, such as a horizontal linear polarizer, a mirror, and a diffuser plate. In addition, it was also used to image a benign lesion on a human subject. The results of the known samples are in good agreement with their theoretical values with an average accuracy of 97.96% and a standard deviation of 0.0084, using 16 polarization images. The system accuracy was further increased to 99.44% with a standard deviation of 0.005, when 36 images were used to generate the Mueller matrix. © 2002 Society of Photo-Optical Instrumentation Engineers.

1 January 2010 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
BMBilal Malik
Bilal Malik
GCGerard Cote
Gerard Cote
The development of a real-time, dual-wavelength optical polarimetric system to ultimately probe the aqueous humor glucose concentrations as a means of noninvasive diabetic glucose monitoring is the long-term goal of this research. The key impact of the work is the development of an approach for the reduction of the time-variant corneal birefringence due to motion artifact, which is still a limiting factor preventing the realization of such a device. Our dual-wavelength approach utilizes real-time, closed-loop feedback that employs a classical three-term feedback controller and efficiently reduces the effect of motion artifact that appears as a common noise source for both wavelengths. In vitro results are shown for the open-loop system, and although the dual-wavelength system helps to reduce the noise, it is shown that closed-loop control is necessary to bring the noise down to a sufficient level for physiological monitoring. Specifically, in vitro measurement results with the closed-loop dual-wavelength approach demonstrate a sensitivity of 12.8mg∕dl across the physiologic glucose range in the presence of time-variant test cell birefringence. Overall, it is shown that this polarimetric system has the potential to be used as a noninvasive measure of glucose for diabetes.