Ping Xue

Prof. Ping Xue

Department of Physics, Tsinghua University, Beijing 100084, China
orcid

Research Focus & Metrics

Academic Career Length

31Years (1996-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2010 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
SZShiyong Zhao
Shiyong Zhao
YGYing Gu
Ying Gu
Ping XuePing Xue
Ping Xue
JGJin Guo
Jin Guo
TSTingmei Shen
Tingmei Shen
XWXunbin Wei
Xunbin Wei
Port wine stain (PWS) is a congenital disease with 3 to 5‰ incidence.1, 2 The histopathological manifestation is the capillary dilation and malformation in the upper dermis (papillary layer). Photodynamic therapy (PDT), which has been used to treat PWS for the last 2 decade, has advantages including excellent tissue selection, strong lesion effects on microvessels, and few side effects. Therefore, it has become3, 4, 5, 6, 7, 8, 9, 10 one of the most effective therapies for PWS. The mechanism of PDT is that, when the endogenous or exogenous photosensitizer in the tissue is exposed to light of a specific wavelength, it absorbs the photon energy and transits to the excited state, then it soon releases energy and relaxes to its ground singlet state through a physical or chemical deexcitation process, during which a large quantity of reactive oxygen is generated. The singlet oxygen reacts with various biomolecules, resulting in cell killing through apoptosis and/or necrosis, as well as an occlusion effect on blood vessels. The key of applying PDT to PWS is to selectively destroy dilated and malformed capillaries in the upper dermis, while sparing the epidermis and deep dermis. PDT has been used for cancer treatment. Khan,11 Wilson,12 Dougherty,13, 14 Henderson and Dougherty,15 and Dougherty16, 17 used HpD as a photosensitizer combined with red light illumination and achieved good results in treating a dozen of cancer types including breast cancer, uterine cancer, basal cell cancer, and squamous cell carcinoma. The clinical applications become broader as the research on PDT goes deeper. Gu applied PDT in clinical treatment of PWS in 1991 with good clinical effects.18

18 July 2012 in Optics Letters
Verified
Journal Article
Closed access
PDF file
NZNing Zhang
Ning Zhang
THTiancheng Huo
Tiancheng Huo
CWChengming Wang
Chengming Wang
TCTianyuan Chen
Tianyuan Chen
JZJing-Gao Zheng
Jing-Gao Zheng
Ping XuePing Xue
Ping Xue
We propose a novel method called compressed sensing with linear-in-wavenumber sampling (k-linear CS) to retrieve an image for spectral-domain optical coherence tomography (SD-OCT). An array of points that is evenly spaced in wavenumber domain is sampled from an original interferogram by a preset k-linear mask. Then the compressed sensing based on l1 norm minimization is applied on these points to reconstruct an A-scan data. To get an OCT image, this method uses less than 20% of the total data as required in the typical process and gets rid of the spectral calibration with numerical interpolation in traditional CS-OCT. Therefore k-linear CS is favorable for high speed imaging. It is demonstrated that the k-linear CS has the same axial resolution performance with ∼30  dB higher signal-to-noise ratio (SNR) as compared with the numerical interpolation. Imaging of bio-tissue by SD-OCT with k-linear CS is also demonstrated.

14 September 2023 in Nature Communications
Verified
Journal Article
Open access
PDF file
BHBin He
Bin He
YZYuxin Zhang
Yuxin Zhang
LZLu Zhao
Lu Zhao
ZSZhenwen Sun
Zhenwen Sun
XHXiyuan Hu
Xiyuan Hu
NZNing Zhang
Ning Zhang
Data recovery from monolithic storage devices (MSDs) is in high demand for legal or business purposes. However, the conventional data recovery methods are destructive, complicated, and time-consuming. We develop a robotic-arm-assisted optical coherence tomography (robotic-OCT) for non-destructive inspection of MSDs, offering ~7 μm lateral resolution, ~4 μm axial resolution and an adjustable field-of-view to accommodate various MSD sizes. Using a continuous scanning strategy, robotic-OCT achieves automated volumetric imaging of a micro-SD card in ~37 seconds, significantly faster than the traditional stop-and-stare scanning that typically takes tens of minutes. We also demonstrate the robotic-OCT-guided laser ablation as a microsurgical tool for targeted area removal with precision of ±10 μm and accuracy of ~50 μm, eliminating the need to remove the entire insulating layer and operator intervention, thus greatly improving the data recovery efficiency. This work has diverse potential applications in digital forensics, failure analysis, materials testing, and quality control.

1 August 2013 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
TCTianyuan Chen
Tianyuan Chen
NZNing Zhang
Ning Zhang
THTiancheng Huo
Tiancheng Huo
CWChengming Wang
Chengming Wang
JZJing-Gao Zheng
Jing-Gao Zheng
Ping XuePing Xue
Ping Xue
Optical coherence tomography (OCT) is an emerging modality for obtaining cross-sectional images.1 As a noninvasive cross-sectional imaging technique with micrometer resolution, OCT has become very promising in the field of biomedical applications. Due to limitation of the light penetration, small and high-resolution probes for endoscopic OCT have been regarded as powerful tools in examining internal organs.2 There have been various designs of endoscopic OCT probes over the past decade,3 4. 5. – 6 which can be divided into two groups based on the scanning modes: forward scanning and circumferential scanning. Among them, circumferential probes are utilized extensively for imaging within hollow tissues, such as arteries, esophagus, and colon.7 For the circumferential scanning probes, the scanning can be implemented in two ways based on their driving modes:8 proximal scanning or distal scanning.

1 March 2015 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
THTiancheng Huo
Tiancheng Huo
CWChengming Wang
Chengming Wang
XZXiao Zhang
Xiao Zhang
TCTianyuan Chen
Tianyuan Chen
WLWenchao Liao
Wenchao Liao
Ping XuePing Xue
Ping Xue
We present an ultrahigh-speed optical coherence tomography (OCT) based on an all-optical swept-source with an A-scan rate of 40 MHz. The inertia-free swept-source, which has its output power of 41.2 mW and tuning range of 40 nm and high scan linearity in wavenumber with Pearson’s correlation coefficients r of 0.9996, consists of a supercontinuum laser, an optical band-pass filter, a linearly chirped fiber Bragg grating, an erbium-doped fiber amplifier, and two buffer stages. With sensitivity of 87 dB, high-speed OCT imaging of biological tissue in vivo is also demonstrated. Huo, Wang, Zhang, Chen, Liao, Zhang, Ai, Hsieh, and Xue: Ultrahigh-speed optical coherence tomography utilizing all-optical 40 MHz swept-source Optical coherence tomography (OCT) has attracted much attention since it was introduced in the 1990s.1 Nowadays, there is an increasing need for volumetric imaging in real time, resulting in the demand for higher imaging speed.2 3. 4. – 5 Swept-source OCT (SS-OCT) is an attractive and practical modality enabling an ultrahigh-speed A-scan rate. The Fourier domain mode locked laser and the microelectromechanical systems tunable vertical cavity surface-emitting laser have been developed as new light sources for SS-OCT enable high imaging speeds of up to 1 to 20 MHz.6,7 However, the mechanical moving parts of these swept-sources limit the response time and long-term stability. Recently, several high-speed inertia-free or all-optical swept-sources have been demonstrated. Okabe et al. presented an external-cavity swept-source equipped with a KTa1−xNbxO3 crystal deflector.8 Our group has also demonstrated a linear-in-wavenumber swept laser based on an acousto-optic deflector with a swept rate of ∼2  MHz.9 Another approach to high speed all-optical swept-sources is based on a combination of a broadband pulse source and a high-dispersion medium. Moon and Kim introduced an ultrahigh-speed SS-OCT with a stretched pulse supercontinuum source (SC) at a scanning rate of 5 MHz.10 Goda et al. reported a high-throughput OCT system with an A-scan rate of 90.9 MHz at 800 nm.11 However, no OCT images of biological tissues were demonstrated in all these optical time-stretch swept-source-based OCT systems. Xu et al. demonstrated amplified optical time-stretch and all-fiber breathing laser-based all-optical ultrahigh-speed SS-OCT at an A-scan rate of 7.14 and 11.5 MHz, respectively.12,13 However, the effective A-scan rate of the former was only 1.2 MHz due to the averaging processes and the spectral shape of the latter swept-source was far away from the Gaussian shape as required for OCT imaging. Park et al.14 demonstrated an ultrahigh-speed optical frequency domain reflectometry system based on linearly chirped fiber Bragg gratings (LCFBGs) at 20 MHz repetition rate but with an output spectrum of only 9.2 nm, much less than needed for OCT. In this letter, we demonstrate all-optical SS-OCT based on the buffered optical time-stretch technique utilizing LCFBG as the dispersive medium and achieve a linear-in-wavenumber tuning range of 40 nm at an A-scan rate of 40 MHz. The configuration of the swept-source is illustrated in Fig. 1. The SC with a pulse width of 150 ps, output power of 2 W, and spectrum of 460 to 2000 nm provides a broadband pulse train at a repetition rate of 10 MHz and is coupled into a single-mode fiber. Filtered by a circulator and LCFBG 1, the spectrum with a center wavelength of 1550 nm and full width at half maximum bandwidth of 52 nm enters the photonic time stretcher that consists of a circulator and LCFBG 2. The spectrum of each broadband pulse is converted into a temporal waveform by the large group velocity dispersion (GVD) of the LCFBG 2 with a duty cycle <25%. The buffer stages15 are used to fill up the duty cycle to 100% and further increase the swept rate with delayed copies of one scan by 4×. The erbium-doped fiber amplifier (EDFA) is integrated for shaping the spectrum and increasing the power to enhance the SS-OCT sensitivity. The basic parameters of the swept-source, including the bandwidth Δλ, time duration Δτ, axial depth range Δzmax, and swept repetition rate R, are theoretically obtained.14,16,17 Though the bandwidth of the band-pass filter and the LCFBG 2 is 50 nm, the gain bandwidth of the EDFA is only 40 nm. Therefore, Δλ is 40 nm and Δτ is revised as 19.8 ns. Thus, the theoretical axial resolution is 26  μm. The axial depth range Δzmax is generally limited by the GVD of the dispersive element, the sampling rate of the A/D converter, and the analog bandwidth (B) of the dual-balanced photo-detector, which are −496  ps·nm−1, 2  GS/s, and 1.6 GHz, corresponding to the axial depth limits of 7.1, 0.59, and 0.47 mm, respectively. Considering all of the above limits, the theoretical axial depth range of our SS-OCT system is 0.47 mm. The buffering further increases the swept rate by 4×, therefore, the swept repetition rate R is 40 MHz. The time-stretch interferograms captured by the high-speed oscilloscope are shown in Fig. 2(a). Without any calibrations,12 the temporal swept waveform (short dot line) dramatically shows a good agreement with the spectrum (solid line) captured by an optical spectrum analyzer, as shown in Fig. 2(b). With a total GVD of −496  ps·nm−1, the full-swept range of 40 nm is mapped into a time span of 21 ns, which is consistent with the theoretical value of 19.8 ns, corresponding to a ∼100% duty cycle. The optical power from the LCFBG 1 is ∼1  mW, which extremely limits the system sensitivity. Therefore, optical amplification, i.e., EDFA, is necessary. With ∼38  μW power input in EDFA, the output of the 40 MHz swept-source is 41.2 mW. <!-- named anchor --> Fig. 1 Schematic of the buffered optical time-stretch-based 40 MHz swept-source. SC, supercontinuum source; colli, collimator; SMF, single-mode fiber; PC, polarization controller. <!-- named anchor --> Fig. 2 (a) 40 MHz real-time time-stretch interferograms. The signal in the solid rectangle is the original fringes, and the later three are its copy by the buffer stages. (b) Raw spectra after the LCFBG2 are captured by an optical spectrum analyzer (solid line) and by a high-speed oscilloscope (short dotted line). We use a flat mirror at the sample position of 50  μm to evaluate the point spread function (PSF). The optical power incident on the specimen is ∼25.5  mW for 40 MHz SS-OCT with a theoretical sensitivity of 90 dB. The measured axial resolution by the PSF is 27  μm, in good agreement with the theoretical calculation of 26  μm. The sensitivity is measured with a 1% negative differential conductivity filter in the sample arm. As shown in Fig. 3(a), the sensitivity of the 40 MHz system is 86.7 dB, only 3.3 dB below the theoretical limit, implying that the overall performance of the system including the swept source is good. The sensitivity limitations are due to the limited optical power, the inevitable insertion losses of all the fiber components, the spectral fluctuation of the broadband source, and the noise of the EDFA. Limited sampling rate of the A/D converter may also reduce the quality of the OCT image due to the sparse data points at a high A-scan rate of 40 MHz. To further improve the image quality for clinical applications, higher optical power, more stable pumping for the SC source, and a faster A/D converter are to be employed in future. We plot the different PSFs by varying the mirror position, as shown in Fig. 3(b). The −6  dB imaging depth is 0.42 mm, also in good agreement with the theoretical depth range of 0.47 mm. <!-- named anchor --> Fig. 3 (a) Measured point spread function (PSF) on a logarithmic scale at a position of 50  μm with a −6  dB axial resolution of 26.9  μm and sensitivity of 86.7 dB. The noise floor is calculated from the points in the A rectangle, as the points in the B rectangle are out of the bandwidth limits of the photo-detector. (b) Fall-off performance of the swept-source optical coherence tomography (SS-OCT). Based on the principles of the optical time-stretch technique,14,16,17 the one-to-one mapping between the optical frequency (ω) and the time (T) in the reference frame of the pulse that propagates at the group velocity is given by T(ω)=β2(ω−ω0)z, where ω0 is the central optical frequency, z is the propagation distance, and β2 is the second-order dispersion coefficient. Because LCFBGs provide a practically flat gain and linear group delay, β2 is almost a constant. Therefore, the swept-source scans the wavenumber linearly with time. In Fig. 4(a), the wavenumber versus time curve (dashed line) is obtained from the fringes (solid line) at a 40 MHz swept rate with a fiber-based Mach–Zehnder interferometer, in which the arm difference is set to be ∼0.1  mm. The Pearson’s r is 0.9996 in the fitted linear curve (short dotted line). The integrated relative frequency error χ, defined as a measure for the swept linearity,18 is 0.0002, as shown in Fig. 4(b). <!-- named anchor --> Fig. 4 (a) Fringes (with Gaussian window, solid line), the wavenumber versus time curve (dashed line) and its linear fit (short dotted line); (b) relative frequency error curve of the 40 MHz swept-source. To illustrate the performance of the 40 MHz swept-source, SS-OCT imaging of the intralipid injected into a glass tube and human palm is implemented, as shown in Figs. 5(c) and 5(d). Due to the analog bandwidth upper limit of the acquisition system, the recordable imaging depth is not enough for viewing the whole cross section of the tube. Therefore, in comparison, a 10 MHz swept-source-based SS-OCT imaging with a fourfold larger imaging depth is also given, as shown in Figs. 5(a) and 5(b). The configuration of the 10 and 40 MHz swept-source is almost the same, except that the LCFBG2 in the 40 MHz swept-source is replaced by LCFBG 3 and the buffered stage is removed in the 10 MHz swept-source. With an input power of ∼38  μW in the EDFA, the output power of the 10 MHz swept-source is 40.5 mW. The optical power incident on the specimen is ∼25.1  mW for 10 MHz SS-OCT with the theoretical sensitivity of 90 dB. With a total GVD of −2312  ps·nm−1, its full-swept range of 40 nm is mapped into a time span of 91.2 ns. The axial resolution, −6  dB imaging depth, and sensitivity of the 10 MHz SS-OCT are 27  μm, 1.95 mm, and 85.5 dB, respectively. <!-- named anchor --> Fig. 5 Two-dimensional (2-D) cross-sectional imaging of intralipid injected into a glass cube by (a) (423×200  pixels) 10 MHz swept-source and (c) (423×50  pixels) 40 MHz swept-source. 2-D cross-sectional imaging of human palm by (b) (564×200  pixels) 10 MHz swept-source and (d) (564×50  pixels) 40 MHz swept-source. The scale bar represents 500  μm. (e) Schematic for the sample in (a) and (c). The intralipid was injected into a glass tube with an outer diameter of 1.2 mm and inner diameter of ∼1  mm. It is worthwhile to mention that all imaging is implemented without any averaging12 of the consecutive A-scan signal. As shown in Fig. 5, our ultrahigh-speed SS-OCT can clearly reveal the structure of the epidermis and dermis layers. With a faster photo-detector and data acquisition card, the maximum imaging depth could reach ∼7  mm, as implied by the quality of the image in Fig. 5, because the signal in the deep depth does not have much falloff. Meanwhile, it is possible to superimpose more LCFBGs to enlarge the spectral range and to achieve higher axial resolution. In summary, a 40 MHz all-optical swept-source at 1545 nm with a 3 dB tuning range of 40 nm, output power of 41.2 mW,...

28 June 2012 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
JZJing-Gao Zheng
Jing-Gao Zheng
TCTianyuan Chen
Tianyuan Chen
CWChengming Wang
Chengming Wang
NTNing Tian
Ning Tian
FZFengying Zhao
Fengying Zhao
DLDanyu Lu
Danyu Lu
Early patterning and polarity is of fundamental interest in preimplantation embryonic development. Label-free subcellular 3D live imaging is very helpful to its related studies. We have developed a novel system of full-field optical coherence tomography (FF-OCT) for noninvasive 3D subcellular live imaging of preimplantation mouse embryos with no need of dye labeling. 3D digitized embryos can be obtained by image processing. Label-free 3D live imaging is demonstrated for the mouse embryos at various typical preimplantation stages with a spatial resolution of 0.7 µm and imaging rate of 24 fps. Factors that relate to early patterning and polarity, such as pronuclei in zygote, shapes of zona pellucida, location of second polar body, cleavage planes, and the blastocyst axis, can be quantitatively measured. The angle between the two second cleavage planes is accurately measured to be 87 deg. It is shown that FF-OCT provides a potential breakthrough for early patterning, polarity formation, and many other preimplantation-related studies in mammalian developmental biology. Zheng, Lu, Chen, Wang, Tian, Zhao, Huo, Zhang, Chen, Ma, Sun, and Xue: Label-free subcellular 3D live imaging of preimplantation mouse embryos with full-field optical coherence tomography Early patterning and polarity of mammalian embryos are fundamental and important in developmental biology. The early mammalian embryos have been thought to be highly regulative and many embryologists assume that there is no prepatterning during early development.1 2. – 3 However, recent studies have proposed that factors in early patterning such as pronuclei,4 zona pellucida (ZP),5 second polar body (2PB),6 the first, and second two cleavages,7 8. – 9 are associated with the polarity axis in several ways, but some of these findings are not consistent with each other. Whether these factors play decisive roles in the establishment of the polarity has yet to be defined. The controversies not only arise from the remarkable regulating capacity of embryos, but also from experimental methods used in the related investigations. Most of the studies involved dye-labeling techniques. Though some groups claimed that their labeling did not affect the normal development,4,6,9 this does not exclude the possibilities of latent disturbances to the normal processes. On the other hand, most of the current findings are based on 2D imaging methods, such as conventional microscope and differential interference contrast microscopy.5 6. 7. – 8 In such investigations, spatial localizations of related factors can only be qualitatively analyzed but not correctly quantified. Also, most embryos are not well oriented;4 their relative positions are often a puzzle to observers. To solve the problem, a few groups utilized 3D imaging techniques such as confocal laser scanning microscopy and multi-photon excitation laser scanning microscopy,5,9,10 but they all required sample preprocessing and dye labeling. Furthermore, when using these systems, optical damage to the sample is not ignorable, as the optical power density is as high as 106 to 109  W/cm2.11 Therefore, label-free 3D imaging techniques with low optical dose are in high demand in the study of early patterning and polarity. As an extension of optical coherence tomography (OCT), FF-OCT is an emerging technology for submicron-scale label-free 3D imaging.12 13. – 14 FF-OCT detects back-scattered light rather than fluorescence, requiring no labeling nor preprocessing. Equipped with broad-band light source and high N.A. microscope objectives, FF-OCT is capable of achieving 3D images with subcellular resolution in both longitudinal and transverse directions. Furthermore, the entire field of view is uniformly illuminated with the average optical power density only of 10−1   W/cm2, about 7 to 10 orders of magnitude lower than confocal imaging. Therefore, the sample receives much less optical dose, which is favorable for long-time and live observation. These unique characteristics make FF-OCT a powerful imaging methodology in biomedical studies.15 16. 17. 18. – 19 The potential of OCT in developmental biology has been successfully demonstrated using different animals including Xenopus laevis,20 Brachydanio rerio,21 embryonic avian heart,22,23 mouse, and rat.24,25 However, until now there have been no related live studies with mammalian embryos at the very beginning of their embryonic lives, which are important for understanding early patterning and polarity. This is because that the incubating condition and low optical dose requirement of the mammalian embryos during the first 3 to 4 days of embryonic life is critical for live imaging. Furthermore, imaging of the mammalian preimplantation embryos, which is relatively small in size, is technically more challenging. In this paper, FF-OCT was applied to image early patterning and polarity of preimplantation mouse live embryos and obtain label-free 3D subcellular structural images at various typical preimplantation stages, including zygote, two-cell, four-cell, and blastocyst stages. The schematic of FF-OCT setup is shown in Fig. 1(a). It was based on Linnik interference microscope with a tungsten-halogen lamp. The optical power was 0.5 mW, corresponding to an optical power density of 0.2  W/cm2. The interferograms were digitized by a charge-coupled device (CCD) camera (IMPERX, MDC-1004, 1004×1004  pixels, 48 Hz). Two identical water-immersion microscope objectives (Nikon 20×, 0.5 N.A.) were utilized in both arms, achieving a transverse resolution of 0.7 µm. The central wavelength of the light source was 600 nm and the spectral bandwidth 180 nm, corresponding to a depth resolution of 0.7 µm in water. A polished YAG crystal was placed in the reference arm and attached to a piezoelectric transducer (PZT). PZT was used to extract enface tomographic signals of the sample.12 A motorized translation stage was placed in the sample arm to get a 3D volumetric image. To keep the embryos alive for live imaging, we integrated a custom-designed incubator on the translation stage providing 37°C, 5% CO2. 3D reconstruction and the segmentation were performed with commercial software platform 3Dmed 3.0 and Amira 5.2.0. <!-- named anchor --> Fig. 1 (a) Schematic diagram of FF-OCT based on the Linnik interference microscope. BS, beam splitter; MO, microscope objectives (water-immersion, 20×, 0.4 NA); Lens (300 mm focal length); PZT, piezoelectric transducer; CCD, silicon charged-coupled device. (b) 3D reconstruction of a zygote stage embryo with FF-OCT. (c) Cross-section view of the same embryo. ZP, zygote, 2PB and three dark areas (DA1, DA2, and DA3) are clearly distinguishable. (d) 3D reconstruction of three dark areas. Three vertices of the triangle are 3D geometry centers of three dark areas and corresponding three lengths are 19.1, 44.0, and 25.7 µm. (e) 3D reconstruction of three nuclei (2PBN, FPN, and MPN) labeled with Hoechst 33342. Three vertices of the triangle are 3D fluorescence centers of the nuclei and three lengths are 19.1, 44.4, and 26.0 µm. As the mouse is an excellent model to investigate early patterning and polarity of mammalian development, wild-type eight-week-old female ICR/CD1 mice (Laboratory Animal Facility, Tsinghua University, China) were used in our studies. Females were mated overnight with males and examined for vaginal plugs. The presence of a plug was taken as embryonic day 0.5 (E0.5 for short). Zygote, two-cell, four-cell, and blastocyst stage embryos were obtained at E0.5, early E1.5, late E1.5, and E3.5, respectively. Embryos were imaged in a droplet of human tubal fluid medium with 20% FBS (Hyclone, USA). For each embryo, about 70 optical slices were needed with a step of 1.2 µm. Using two phase-shifting modulation12 and averaging 30 images at the same depth, the total acquisition time for each embryo was about 90 s, with an imaging rate of 24 fps. Figure 1(b) shows 3D reconstruction of a zygote stage (E0.5) embryo, and the cross-section view in Fig. 1(c). Besides ZP, zygote, and 2PB, three relatively dark areas (DA1, DA2, and DA3) are also clearly visible. Two of them lie in the zygote and the third in the 2PB. 3D reconstruction of three dark areas segmented from the image stack is shown in Fig. 1(d). By the size, shape, and location, the dark areas were ascertained to be the nuclei. To confirm this, DNAs of the same embryo were stained with Hoechst 33342 and scanned with two-photon laser scanning microscopy (TPLSM). Figure 1(e) shows 3D reconstruction of three nuclei [from left to right, three nuclei are the nucleus of the 2PB (2PBN), female pronucleus (FPN), and male pronucleus (MPN), respectively].26 Owing to TPLSM’s capability of 3D quantitative measurement, a triangle, whose vertices are fluorescence centers of three nuclei, was characterized. The lengths of three sides were 19.1, 44.4 and 26.0 µm, respectively, shown in Fig. 1(e). In comparison, a similar triangle was also measured with FF-OCT. Its vertices were 3D geometry centers of the three dark areas in FF-OCT image, shown in Fig. 1(d). The corresponding side lengths of the triangle were measured to be 19.1, 44.0, and 25.7 µm, perfectly coincident with the TPLSM’s measurements with an accuracy of FF-OCT resolution. Furthermore, FF-OCT image gave essentially the same volumes of three dark areas as those of corresponding nuclei in TPLSM image. Therefore, we may affirm that the dark areas in the FF-OCT image are no other than the nuclei. On the other hand, chromatin is structurally loose during interphase, and its size is far below the wavelength of light. Therefore, the nucleus, whose main part is chromatin, has a low level of scattering signal and shows relatively dark in FF-OCT image. As different organelles have different scattering coefficients and thus give different grey-level signals, FF-OCT is also a functional imaging technique capable of distinguishing functional areas in a cell without any dye labeling. <!-- named anchor --> Fig. 2 (a) A 2D image of a two-cell stage embryo with conventional 2D microscope. The first cleavage plane and BM2 do not clearly appear in the observation plane. (b) 3D reconstruction of the same embryo after rotational operation to the 3D dataset. Major structures are all clearly revealed. (c) 3D reconstruction of a four-cell stage embryo. Plane 1 where BM1 and BM2 contact with each other is observable. (d) At the opposite angle of view, Plane 2 where BM3 and BM4 contact with each other is observable. The two planes are nearly perpendicular to each other. (e) 3D reconstruction of a blastocyst (also shown in Video 1). (f) Cross-section view of the same blastocyst. Blastocoele, trophoblast, and ICM are clearly visible. (g) 3D reconstruction of the segmented nuclei of this blastocyst. Point O is the geometry center of the whole blastocyst and Point O′ is that of the ICM. Em-Ab axis is defined by the line which contains the two points O and O′. (Video 1, MOV, 3.7 MB). [URL: http://dx.doi.org/10.1117/1.JBO.17.7.070503.1]. Figure 2(a) shows a two-cell stage (early E1.5) embryo imaged by a conventional 2D microscope whose first cleavage plane, 2PB, and Blastomere 2 (BM2) do not clearly appear in the observation plane. However, FF-OCT can give a 3D digital dataset of an embryo. By some quantitative rotational operation to the 3D dataset, one can readily observe all the major structural information of two-cell embryo. The same embryo is shown in Fig. 2(b) with its ZP, 2PB, BM1, BM2, and the first cleavage plane clearly displayed. Therefore, no matter how the embryo orients in the observation plane, by FF-OCT imaging and image processing, one can make full use of all the sample embryos, without any exclusion of sample embryo due to improper orientation. 3D reconstruction of a four-cell stage (late E1.5) embryo is shown in Fig. 2(c) and 2(d). There are a total of six planes where cells contact with each other in this tetrahedral-shaped embryo. All six planes are able to be revealed at different angles of view, and one pair of them is shown in Fig. 2(c) and 2(d). The angle between these two planes is measured to be 87 deg, which is significant for normal embryonic development, because second two divisions have already decided the fates of blastomeres and the angle may be one of the reasons for this.7 8. – 9 Other parameters such as spatial locations, relative distances, and volumes of four blastomeres can also be precisely measured using the 3D dataset obtained with FF-OCT. 3D reconstruction of a blastocyst stage (E3.5) embryo is shown in Fig. 2(e), and the cross-section view in Fig. 2(f). The 3D view of the same embryo at different angles is demonstrated in Video 1. Besides blastocoele, the structure of inner cell mass (ICM), which is biologically defined as the mass of cells inside a blastocyst, and trophoblast, biologically defined as the cells forming the outer layer of a blastocyst, are also clearly visible. The segmented nuclei of ICM and trophoblast are shown in Fig. 2(g). The spatial locations of cells can be measured by calculating every center of the dark areas. The embryonic-abembryonic axis in Fig. 2(g) is then characterized by the line that contains the geometry centers of the whole blastocyst (marked with O) and inner cells (O′). Incorrect positioning of polarity axis due to the limitation of the traditional measurement may be one of the possible causes for the controversies in understanding early development, while accurate measurement of polarity axis with FF-OCT in this way is more reliable and may be the key to clarify them. In conclusion, FF-OCT, as a label-free 3D imaging technique, is demonstrated to image the mouse live embryos at various typical preimplantation stages with a spatial resolution of 0.7 µm and imaging rate of 24 fps. Factors that relate to early patterning and polarity such as pronuclei, ZP, 2PB, cleavage planes, and blastocyst axis are quantitatively measured. The angle between the two second cleavage planes is accurately measured to be 87 deg. FF-OCT offers a powerful methodology for the study of early patterning, polarity formation, and many other preimplantation-related research in the mammalian developmental biology. <!-- named anchor --> Acknowledgments This work was sponsored in part by the Ministry of Science and Technology of China contracts 2006AA02Z472, 2007CB511904, 001CB510307 and 2009CB929400, by the National Natural Science Foundation of China Grants 90508001, 10676014 and 10574081, and by the Tsinghua Initiative Scientific Research Program 2010THZ01. <!-- named anchor --> <!-- named anchor --> References <!-- named anchor --> 1. <!-- named anchor --> A. K. Tarkowski, “Experiments on the development of isolated blastomeres of mouse eggs,” Nature 184(4695), 1286–1287 (1959).NATUAS0028-0836 http://dx.doi.org/10.1038/1841286a0 Google Scholar <!-- named anchor --> 2. <!-- named anchor --> Y. TsunodaA. McLaren, “Effect of various procedures on the viability of mouse embryos containing half the normal number of blastomeres,” J. Reprod. Fertil. 69(1), 315–322 (1983).JRPFA40022-4251 http://dx.doi.org/10.1530/jrf.0.0690315 Google Scholar <!-- named anchor --> 3. <!-- named anchor --> M. A. CiemerychD. MesnardM. Zernicka-Goetz, “Animal and vegetal poles of the mouse egg predict the polarity of the embryonic axis, yet are nonessential for development,” Development 127(16), 3467–3474 (2000).68KCAI0950-1991 Google Scholar <!-- named anchor --> 4. <!-- named anchor --> T. HiiragiD. Solter, “First cleavage plane of the mouse egg is not predetermined but defined by the topology of the two apposing pronuclei,” Nature 430(6997), 360–364 (2004).NATUAS0028-0836 http://dx.doi.org/10.1038/nature02595 Google Scholar <!-- named anchor --> 5. <!-- named anchor --> Y. Kurotakiet al., “Blastocyst axis is specified independently of early cell lineage but aligns with the ZP shape,” Science 316(5825), 719–723 (2007).SCIEAS0036-8075 http://dx.doi.org/10.1126/science.1138591 Google Scholar <!-- named anchor --> 6. <!-- named anchor --> D. Grayet al., “First cleavage of the mouse embryos responds to change in egg shape at fertilisation,” Curr. Biol. 14(5), 397–405 (2004).CUBLE20960-9822 http://dx.doi.org/10.1016/j.cub.2004.02.031 Google Scholar <!-- named anchor --> 7. <!-- named anchor --> K. PiotrowskaM. Zernicka-Goetz, “Role for sperm in spatial patterning of early mouse embryos,” Nature 409(6819), 517–521 (2001).NATUAS0028-0836 http://dx.doi.org/10.1038/35054069 Google Scholar <!-- named anchor --> 8. <!-- named anchor --> R. L. Gardner, “Experimental analysis of second cleavage in the mouse,” Hum. Reprod. 17(12), 3178–3189 (2002).HUREEE0268-1161 http://dx.doi.org/10.1093/humrep/17.12.3178 Google Scholar <!-- named anchor --> 9. <!-- named anchor --> K. Piotrowskaet al., “Blastomeres arising from the first cleavage division have distinguishable fates in normal mouse development,” Development 128(19), 3739–3748 (2001).68KCAI0950-1991 Google Scholar <!-- named anchor --> 10. <!-- named anchor --> K. McDoleet al., “Lineage mapping the pre-implantation mouse embryo by two-photon microscopy, new insights into the segregation of cell fates,” Dev. Biol. 355(2), 239–249 (2011).DEBIAO0012-1606 http://dx.doi.org/10.1016/j.ydbio.2011.04.024 Google Scholar <!-- named anchor --> 11. <!-- named anchor --> M. Göppert-Mayer, “Über Elementarakte mit zwei Quantensprüngen,” Ann. Phys. 401(3), 273–294 (1931).ANPYA20003-3804 http://dx.doi.org/10.1002/(ISSN)1521-3889...