14 September 2023 in Nature Communications
Data recovery from monolithic storage devices (MSDs) is in high demand for legal or business purposes. However, the conventional data recovery methods are destructive, complicated, and time-consuming. We develop a robotic-arm-assisted optical coherence tomography (robotic-OCT) for non-destructive inspection of MSDs, offering ~7 μm lateral resolution, ~4 μm axial resolution and an adjustable field-of-view to accommodate various MSD sizes. Using a continuous scanning strategy, robotic-OCT achieves automated volumetric imaging of a micro-SD card in ~37 seconds, significantly faster than the traditional stop-and-stare scanning that typically takes tens of minutes. We also demonstrate the robotic-OCT-guided laser ablation as a microsurgical tool for targeted area removal with precision of ±10 μm and accuracy of ~50 μm, eliminating the need to remove the entire insulating layer and operator intervention, thus greatly improving the data recovery efficiency. This work has diverse potential applications in digital forensics, failure analysis, materials testing, and quality control.
23 May 2024 in International Journal of Computer Vision
1 June 2018 in Forensic Science International
1 September 2016 in Forensic Science International
16 December 2022 in IEEE Journal of Selected Topics in Quantum Electronics
Optical coherence tomography angiography (OCTA) can provide depth resolved image of microvasculature but fail to acquire both high resolution and large field imaging of an irregular sample. The robotic arm can easily scan along the sample surface to ensure that the sample at the same depth is all in the same focal plane, so OCTA can be obtained without the effect of unevenly distributed resolution and fall off as occurred in conventional imaging with linear scanning of irregular sample. So, we integrated a 120 kHz OCT with a robotic arm and proposed a novel calibration method for robotic arm with a repeatability positioning accuracy of ∼60μm. A correlation mapping (CM) masked eigen decomposition OCTA was proposed with CM > 0.6 for binarization to improve the vascular visualization and CM > 0.99 for extraction of big vessels to enhance stitching efficacy. With the aid of robotic arm, micro-vascular OCTA of whole mouse brain was achieved for the first time, to our knowledge, over a volume size of 10 mm × 8.1 mm × 1 mm with a resolution of ∼4μm(axial) x ∼6μm(lateral). We believe robot assisted OCTA system will have great potential in biomedical application like intraoperative navigation and other fields.
20 July 2020 in Journal of Forensic Sciences