Xiao Zhang

Xiao Zhang

Auto-generated profile, based on publicly available information

Xiao Zhang

School of Medical Technology, Beijing Institute of Technology, Beijing, China

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 November 2022 in Artificial Intelligence
Verified
Journal Article
Closed access
XLXuhong Li
Xuhong Li
HXHaoyi Xiong
Haoyi Xiong
XLXingjian Li
Xingjian Li
XZXiao Zhang
Xiao Zhang
JLJi LIU
Ji LIU
DDDejing Dou
Dejing Dou

10 December 2013 in Laser Physics
Verified
Journal Article
Closed access
PDF file
ZYZhenhua Yu
Zhenhua Yu
YWYonggang Wang
Yonggang Wang
XZXiao Zhang
Xiao Zhang
XDXinzheng Dong
Xinzheng Dong
JTJinrong Tian
Jinrong Tian
YSYanrong Song
Yanrong Song
We demonstrate a highly stable mode locked fiber laser based on single wall carbon nanotubes. The mode locking is achieved by the evanescent field interaction of the propagating light with a single wall carbon nanotube saturable absorber in a microfiber. The pulse width is 66 fs, which, to the best of our knowledge, is the shortest pulse achieved in a carbon nanotube mode locked fiber laser. The maximum average output power is 26 mW, which is about 20 times larger than that of a typical carbon nanotube mode locked fiber laser. The center of the wavelength is 1555 nm, with 54 nm spectral width. The repetition rate is 146 MHz. To investigate the laser’s stability, the output pulses are monitored for 120 h and there is no significant degradation of the laser spectral width or shape.

1 March 2015 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
THTiancheng Huo
Tiancheng Huo
CWChengming Wang
Chengming Wang
XZXiao Zhang
Xiao Zhang
TCTianyuan Chen
Tianyuan Chen
WLWenchao Liao
Wenchao Liao
Ping XuePing Xue
Ping Xue
We present an ultrahigh-speed optical coherence tomography (OCT) based on an all-optical swept-source with an A-scan rate of 40 MHz. The inertia-free swept-source, which has its output power of 41.2 mW and tuning range of 40 nm and high scan linearity in wavenumber with Pearson’s correlation coefficients r of 0.9996, consists of a supercontinuum laser, an optical band-pass filter, a linearly chirped fiber Bragg grating, an erbium-doped fiber amplifier, and two buffer stages. With sensitivity of 87 dB, high-speed OCT imaging of biological tissue in vivo is also demonstrated. Huo, Wang, Zhang, Chen, Liao, Zhang, Ai, Hsieh, and Xue: Ultrahigh-speed optical coherence tomography utilizing all-optical 40 MHz swept-source Optical coherence tomography (OCT) has attracted much attention since it was introduced in the 1990s.1 Nowadays, there is an increasing need for volumetric imaging in real time, resulting in the demand for higher imaging speed.2 3. 4. – 5 Swept-source OCT (SS-OCT) is an attractive and practical modality enabling an ultrahigh-speed A-scan rate. The Fourier domain mode locked laser and the microelectromechanical systems tunable vertical cavity surface-emitting laser have been developed as new light sources for SS-OCT enable high imaging speeds of up to 1 to 20 MHz.6,7 However, the mechanical moving parts of these swept-sources limit the response time and long-term stability. Recently, several high-speed inertia-free or all-optical swept-sources have been demonstrated. Okabe et al. presented an external-cavity swept-source equipped with a KTa1−xNbxO3 crystal deflector.8 Our group has also demonstrated a linear-in-wavenumber swept laser based on an acousto-optic deflector with a swept rate of ∼2  MHz.9 Another approach to high speed all-optical swept-sources is based on a combination of a broadband pulse source and a high-dispersion medium. Moon and Kim introduced an ultrahigh-speed SS-OCT with a stretched pulse supercontinuum source (SC) at a scanning rate of 5 MHz.10 Goda et al. reported a high-throughput OCT system with an A-scan rate of 90.9 MHz at 800 nm.11 However, no OCT images of biological tissues were demonstrated in all these optical time-stretch swept-source-based OCT systems. Xu et al. demonstrated amplified optical time-stretch and all-fiber breathing laser-based all-optical ultrahigh-speed SS-OCT at an A-scan rate of 7.14 and 11.5 MHz, respectively.12,13 However, the effective A-scan rate of the former was only 1.2 MHz due to the averaging processes and the spectral shape of the latter swept-source was far away from the Gaussian shape as required for OCT imaging. Park et al.14 demonstrated an ultrahigh-speed optical frequency domain reflectometry system based on linearly chirped fiber Bragg gratings (LCFBGs) at 20 MHz repetition rate but with an output spectrum of only 9.2 nm, much less than needed for OCT. In this letter, we demonstrate all-optical SS-OCT based on the buffered optical time-stretch technique utilizing LCFBG as the dispersive medium and achieve a linear-in-wavenumber tuning range of 40 nm at an A-scan rate of 40 MHz. The configuration of the swept-source is illustrated in Fig. 1. The SC with a pulse width of 150 ps, output power of 2 W, and spectrum of 460 to 2000 nm provides a broadband pulse train at a repetition rate of 10 MHz and is coupled into a single-mode fiber. Filtered by a circulator and LCFBG 1, the spectrum with a center wavelength of 1550 nm and full width at half maximum bandwidth of 52 nm enters the photonic time stretcher that consists of a circulator and LCFBG 2. The spectrum of each broadband pulse is converted into a temporal waveform by the large group velocity dispersion (GVD) of the LCFBG 2 with a duty cycle <25%. The buffer stages15 are used to fill up the duty cycle to 100% and further increase the swept rate with delayed copies of one scan by 4×. The erbium-doped fiber amplifier (EDFA) is integrated for shaping the spectrum and increasing the power to enhance the SS-OCT sensitivity. The basic parameters of the swept-source, including the bandwidth Δλ, time duration Δτ, axial depth range Δzmax, and swept repetition rate R, are theoretically obtained.14,16,17 Though the bandwidth of the band-pass filter and the LCFBG 2 is 50 nm, the gain bandwidth of the EDFA is only 40 nm. Therefore, Δλ is 40 nm and Δτ is revised as 19.8 ns. Thus, the theoretical axial resolution is 26  μm. The axial depth range Δzmax is generally limited by the GVD of the dispersive element, the sampling rate of the A/D converter, and the analog bandwidth (B) of the dual-balanced photo-detector, which are −496  ps·nm−1, 2  GS/s, and 1.6 GHz, corresponding to the axial depth limits of 7.1, 0.59, and 0.47 mm, respectively. Considering all of the above limits, the theoretical axial depth range of our SS-OCT system is 0.47 mm. The buffering further increases the swept rate by 4×, therefore, the swept repetition rate R is 40 MHz. The time-stretch interferograms captured by the high-speed oscilloscope are shown in Fig. 2(a). Without any calibrations,12 the temporal swept waveform (short dot line) dramatically shows a good agreement with the spectrum (solid line) captured by an optical spectrum analyzer, as shown in Fig. 2(b). With a total GVD of −496  ps·nm−1, the full-swept range of 40 nm is mapped into a time span of 21 ns, which is consistent with the theoretical value of 19.8 ns, corresponding to a ∼100% duty cycle. The optical power from the LCFBG 1 is ∼1  mW, which extremely limits the system sensitivity. Therefore, optical amplification, i.e., EDFA, is necessary. With ∼38  μW power input in EDFA, the output of the 40 MHz swept-source is 41.2 mW. <!-- named anchor --> Fig. 1 Schematic of the buffered optical time-stretch-based 40 MHz swept-source. SC, supercontinuum source; colli, collimator; SMF, single-mode fiber; PC, polarization controller. <!-- named anchor --> Fig. 2 (a) 40 MHz real-time time-stretch interferograms. The signal in the solid rectangle is the original fringes, and the later three are its copy by the buffer stages. (b) Raw spectra after the LCFBG2 are captured by an optical spectrum analyzer (solid line) and by a high-speed oscilloscope (short dotted line). We use a flat mirror at the sample position of 50  μm to evaluate the point spread function (PSF). The optical power incident on the specimen is ∼25.5  mW for 40 MHz SS-OCT with a theoretical sensitivity of 90 dB. The measured axial resolution by the PSF is 27  μm, in good agreement with the theoretical calculation of 26  μm. The sensitivity is measured with a 1% negative differential conductivity filter in the sample arm. As shown in Fig. 3(a), the sensitivity of the 40 MHz system is 86.7 dB, only 3.3 dB below the theoretical limit, implying that the overall performance of the system including the swept source is good. The sensitivity limitations are due to the limited optical power, the inevitable insertion losses of all the fiber components, the spectral fluctuation of the broadband source, and the noise of the EDFA. Limited sampling rate of the A/D converter may also reduce the quality of the OCT image due to the sparse data points at a high A-scan rate of 40 MHz. To further improve the image quality for clinical applications, higher optical power, more stable pumping for the SC source, and a faster A/D converter are to be employed in future. We plot the different PSFs by varying the mirror position, as shown in Fig. 3(b). The −6  dB imaging depth is 0.42 mm, also in good agreement with the theoretical depth range of 0.47 mm. <!-- named anchor --> Fig. 3 (a) Measured point spread function (PSF) on a logarithmic scale at a position of 50  μm with a −6  dB axial resolution of 26.9  μm and sensitivity of 86.7 dB. The noise floor is calculated from the points in the A rectangle, as the points in the B rectangle are out of the bandwidth limits of the photo-detector. (b) Fall-off performance of the swept-source optical coherence tomography (SS-OCT). Based on the principles of the optical time-stretch technique,14,16,17 the one-to-one mapping between the optical frequency (ω) and the time (T) in the reference frame of the pulse that propagates at the group velocity is given by T(ω)=β2(ω−ω0)z, where ω0 is the central optical frequency, z is the propagation distance, and β2 is the second-order dispersion coefficient. Because LCFBGs provide a practically flat gain and linear group delay, β2 is almost a constant. Therefore, the swept-source scans the wavenumber linearly with time. In Fig. 4(a), the wavenumber versus time curve (dashed line) is obtained from the fringes (solid line) at a 40 MHz swept rate with a fiber-based Mach–Zehnder interferometer, in which the arm difference is set to be ∼0.1  mm. The Pearson’s r is 0.9996 in the fitted linear curve (short dotted line). The integrated relative frequency error χ, defined as a measure for the swept linearity,18 is 0.0002, as shown in Fig. 4(b). <!-- named anchor --> Fig. 4 (a) Fringes (with Gaussian window, solid line), the wavenumber versus time curve (dashed line) and its linear fit (short dotted line); (b) relative frequency error curve of the 40 MHz swept-source. To illustrate the performance of the 40 MHz swept-source, SS-OCT imaging of the intralipid injected into a glass tube and human palm is implemented, as shown in Figs. 5(c) and 5(d). Due to the analog bandwidth upper limit of the acquisition system, the recordable imaging depth is not enough for viewing the whole cross section of the tube. Therefore, in comparison, a 10 MHz swept-source-based SS-OCT imaging with a fourfold larger imaging depth is also given, as shown in Figs. 5(a) and 5(b). The configuration of the 10 and 40 MHz swept-source is almost the same, except that the LCFBG2 in the 40 MHz swept-source is replaced by LCFBG 3 and the buffered stage is removed in the 10 MHz swept-source. With an input power of ∼38  μW in the EDFA, the output power of the 10 MHz swept-source is 40.5 mW. The optical power incident on the specimen is ∼25.1  mW for 10 MHz SS-OCT with the theoretical sensitivity of 90 dB. With a total GVD of −2312  ps·nm−1, its full-swept range of 40 nm is mapped into a time span of 91.2 ns. The axial resolution, −6  dB imaging depth, and sensitivity of the 10 MHz SS-OCT are 27  μm, 1.95 mm, and 85.5 dB, respectively. <!-- named anchor --> Fig. 5 Two-dimensional (2-D) cross-sectional imaging of intralipid injected into a glass cube by (a) (423×200  pixels) 10 MHz swept-source and (c) (423×50  pixels) 40 MHz swept-source. 2-D cross-sectional imaging of human palm by (b) (564×200  pixels) 10 MHz swept-source and (d) (564×50  pixels) 40 MHz swept-source. The scale bar represents 500  μm. (e) Schematic for the sample in (a) and (c). The intralipid was injected into a glass tube with an outer diameter of 1.2 mm and inner diameter of ∼1  mm. It is worthwhile to mention that all imaging is implemented without any averaging12 of the consecutive A-scan signal. As shown in Fig. 5, our ultrahigh-speed SS-OCT can clearly reveal the structure of the epidermis and dermis layers. With a faster photo-detector and data acquisition card, the maximum imaging depth could reach ∼7  mm, as implied by the quality of the image in Fig. 5, because the signal in the deep depth does not have much falloff. Meanwhile, it is possible to superimpose more LCFBGs to enlarge the spectral range and to achieve higher axial resolution. In summary, a 40 MHz all-optical swept-source at 1545 nm with a 3 dB tuning range of 40 nm, output power of 41.2 mW,...

16 December 2022 in IEEE Journal of Selected Topics in Quantum Electronics
Verified
Journal Article
Closed access
HBHe Bin
He Bin
YZYuxin Zhang
Yuxin Zhang
ZMZhe Meng
Zhe Meng
ZHZhijun He
Zhijun He
CZchen zhengyu
chen zhengyu
Ping XuePing Xue
Ping Xue
Optical coherence tomography angiography (OCTA) can provide depth resolved image of microvasculature but fail to acquire both high resolution and large field imaging of an irregular sample. The robotic arm can easily scan along the sample surface to ensure that the sample at the same depth is all in the same focal plane, so OCTA can be obtained without the effect of unevenly distributed resolution and fall off as occurred in conventional imaging with linear scanning of irregular sample. So, we integrated a 120 kHz OCT with a robotic arm and proposed a novel calibration method for robotic arm with a repeatability positioning accuracy of ∼60μm. A correlation mapping (CM) masked eigen decomposition OCTA was proposed with CM > 0.6 for binarization to improve the vascular visualization and CM > 0.99 for extraction of big vessels to enhance stitching efficacy. With the aid of robotic arm, micro-vascular OCTA of whole mouse brain was achieved for the first time, to our knowledge, over a volume size of 10 mm × 8.1 mm × 1 mm with a resolution of ∼4μm(axial) x ∼6μm(lateral). We believe robot assisted OCTA system will have great potential in biomedical application like intraoperative navigation and other fields.

6 January 2014 in Optics Letters
Verified
Journal Article
Closed access
PDF file
THTiancheng Huo
Tiancheng Huo
JZJian Zhang
Jian Zhang
JZJing-Gao Zheng
Jing-Gao Zheng
TCTianyuan Chen
Tianyuan Chen
CWChengming Wang
Chengming Wang
Ping XuePing Xue
Ping Xue
We report a novel linear-in-wavenumber (k-linear) swept laser source based on an acousto-optic deflector (AOD). The AOD-based optical filter includes an acousto-optic deflector and a reflection grating. The laser may tune k linearly in wavenumber over time due to its appropriate configuration and is favorable for fast imaging because it avoids data resampling and recalibration, as are required in conventional swept source optical coherence tomography (SS-OCT). We achieved k-linearity with Pearson’s r correlation coefficients of 0.99995 without and 0.99997 with optimization. The laser has a tuning range of 50 nm, a 3 dB swept range of 42 nm (FWHM), output power of 2.56 mW, 6 dB sensitivity roll-off depth of 0.941 mm, and central wavelength of 1064 nm at a scanning rate of ∼20  kHz. Scanning rate as high as ∼400  kHz is also achieved for this laser with the tuning range 49 nm, swept linearity of 0.99990, output power of 2.30 mW, and a 6 dB sensitivity roll-off depth 0.550 mm. SS-OCT imaging with linear-in-wavenumber swept laser is also demonstrated.

21 November 2016 in Scientific Reports
Verified
Journal Article
Open access
XZXiao Zhang
Xiao Zhang
THTiancheng Huo
Tiancheng Huo
CWChengming Wang
Chengming Wang
WLWenchao Liao
Wenchao Liao
TCTianyuan Chen
Tianyuan Chen
Ping XuePing Xue
Ping Xue
We propose an all-optical Fourier transformation system for real-time massive data processing in high speed optical coherence tomography (OCT). In the so-called optical computing OCT, fast Fourier transformation (FFT) of A-scan signal is optically processed in real time before being detected by photoelectric detector. Therefore, the processing time for interpolation and FFT in traditional Fourier domain OCT can be dramatically eliminated. A processing rate of 10 mega-A-scans/second was experimentally achieved, which is, to our knowledge, the highest speed for OCT imaging. Due to its fiber based all-optical configuration, this optical computing OCT system is ideal for ultrahigh speed volumetric OCT imaging in clinical application.