Ricardo Eliu Lozoya-Ponce

Dr. Ricardo Eliu Lozoya-Ponce

Posgrado de Electronica, Tecnologico Nacional de Mexico, Chihuahua, Mexico
orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 September 2023 in Mathematics
Verified
Journal Article
Open access
PDF file
MMMoises Ramos Martinez
Moises Ramos Martinez
TMTecnológico Nacional de México
Tecnológico Nacional de México
Gerardo Ortiz-TorresGerardo Ortiz-Torres
Gerardo Ortiz-Torres
Felipe D. J. Sorcia-VázquezFelipe D. J. Sorcia-Vázquez
Felipe D. J. Sorcia-Vázquez
Himer Avila-GeorgeHimer Avila-George
Himer Avila-George
Jesse Yoe Rumbo MoralesJesse Yoe Rumbo Morales
Jesse Yoe Rumbo Morales
This paper introduces a new approach to controlling Pressure Swing Adsorption (PSA) using a neural network controller based on a Model Predictive Control (MPC) process. We use a Hammerstein–Wiener (HW) model representing the real PSA process data. Then, we design an MPC-controlled model based on the HW model to maintain the bioethanol purity near 99% molar fraction. This work proposes an Artificial Neural Network (ANN) that captures the dynamics of the PSA model controlled by the MPC strategy. Both controllers are validated using the HW model of the PSA process, showing great performance and robustness against disturbances. The results show that we can follow the desired trajectory and attenuate disturbances, achieving the purity of bioethanol at a molar fraction value of 0.99 using the ANN based on the MPC strategy with 94% of fit in the control signal and a 97% fit in the purity signal, so we can conclude that our ANN can be used to attenuate disturbances and maintain purity in the PSA process.

31 December 2020 in Electronics
Verified
Journal Article
Open access
PDF file
Mario Ponce-SilvaMario Ponce-Silva
Mario Ponce-Silva
Daniel Salazar-PérezDaniel Salazar-Pérez
Daniel Salazar-Pérez
Oscar Rodríguez BenítezOscar Rodríguez Benítez
Oscar Rodríguez Benítez
LVLuis Gerardo Vela-Valdés
Luis Gerardo Vela-Valdés
Abraham SanchezAbraham Sanchez
Abraham Sanchez
Juan AquiJuan Aqui
Juan Aqui
The main contribution of this paper is to show a new AC/DC converter based on the rearrangement of the flyback converter. The proposed circuit only manages part of the energy and the rest is delivered directly from the source to the load. Therefore, with the new topology, the efficiency is increased, and the stress of the components is reduced. The rearrangement consist of the secondary of the flyback is placed in parallel with the load, and this arrangement is connected in series with the primary side and the rectified voltage source. The re-arranged flyback is only a reductive topology and with no magnetic isolation. It was studied as a power supply for LEDs. A low frequency averaged analysis (LFAA) was used to determine the behavior of the proposed circuit and an equivalent circuit much easier to analyze was obtained. To validate the theoretical analysis, a design methodology was developed for the re-arranged flyback converter. The designed circuit was implemented in a 10 W prototype. Experimental results showed that the converter has a THDi = 21.7% and a PF = 0.9686.

13 January 2020 in Asian Journal of Control
Verified
Journal Article
Closed access
PDF file
JBJorge A. Brizuela‐Mendoza
Jorge A. Brizuela‐Mendoza
Felipe D. J. Sorcia-VázquezFelipe D. J. Sorcia-Vázquez
Felipe D. J. Sorcia-Vázquez
Jesse Yoe Rumbo MoralesJesse Yoe Rumbo Morales
Jesse Yoe Rumbo Morales
Ricardo Eliu Lozoya-PonceRicardo Eliu Lozoya-Ponce
Ricardo Eliu Lozoya-Ponce
JRJulio C. Rodríguez‐Cerda
Julio C. Rodríguez‐Cerda

1 March 2021 in Electronics
Verified
Journal Article
Open access
PDF file
JAjesus aguayo alquicira
jesus aguayo alquicira
IVIván Vásquez-Libreros
Iván Vásquez-Libreros
Susana Estefany De León- AldacoSusana Estefany De León- Aldaco
Susana Estefany De León- Aldaco
Mario Ponce-SilvaMario Ponce-Silva
Mario Ponce-Silva
Ricardo Eliu Lozoya-PonceRicardo Eliu Lozoya-Ponce
Ricardo Eliu Lozoya-Ponce
EAEider Miguel Amores-Campos
Eider Miguel Amores-Campos
The cascade multilevel inverters are widely used in industrial manufacturing processes for DC-AC conversion. Therefore, the reliability and efficiency improvement, optimized control, and fault-tolerant strategies are areas of interest for researchers. The fault tolerance strategies applied to cascade multilevel inverters are classified as material redundancy and analytical redundancy. This paper presents the use of the Z-source converter as a fault reconfiguration method applied to a cascade multilevel inverter. On the one hand, the proposed approach has the characteristic of combining the use of material redundancy (modifying the output voltage by changing the Z-source operation), and on the other hand, it has the use of analytical redundancy (modifying the switching sequence of the multilevel inverter, changing from symmetrical to asymmetrical operation mode). This approach has been validated by experimental results of the system under fault-free conditions and employing the Z-source converter as the main fault reconfiguration element. The proposed fault reconfiguration strategy allows the cascaded multilevel inverter to continue to operate even in the presence of a fault by having continuous operation.

13 November 2024 in Electronics
Verified
Journal Article
Open access
PDF file
OVOscar Sánchez Vargas
Oscar Sánchez Vargas
LVLuis Gerardo Vela-Valdés
Luis Gerardo Vela-Valdés
Monica BorundaMonica Borunda
Monica Borunda
Ricardo Eliu Lozoya-PonceRicardo Eliu Lozoya-Ponce
Ricardo Eliu Lozoya-Ponce
JAjesus aguayo alquicira
jesus aguayo alquicira
Susana Estefany De León- AldacoSusana Estefany De León- Aldaco
Susana Estefany De León- Aldaco
Uninterruptible Power Supplies (UPSs) protect electronic equipment by delivering consistent power. Among the core components of a UPS is the inverter, which converts stored DC energy from batteries into AC power. This work focuses on a cascaded multilevel inverter topology for its ability to reduce voltage Total Harmonic Distortion (THD), which is essential for maintaining UPS efficiency and power quality. Using an ANFIS (Adaptive Neuro-Fuzzy Inference System) model, enhanced with the Particle Swarm Optimization (PSO) algorithm, the switching angles were optimized to minimize THD. This work focused on an online UPS with a seven-level inverter structure powered by three LifePo4 S17 batteries, with critical load levels (100%, 95%, 50%, 15%, and 5%) represented in 35 experimental cases. The experimental design allowed the ANFIS-PSO model to adapt to varying voltages, achieving robust THD reduction. The results demonstrated that this combination of ANFIS and PSO provided effective angle optimization, with a low standard deviation of 0.06 between the training and simulated %THD, highlighting the process’s accuracy. The analysis showed that, in most cases, the simulated THD values closely aligned with, or even improved upon, the calculated values, with discrepancies not exceeding 0.2%. These findings support the ANFIS-PSO model’s potential in enhancing power electronics applications, particularly in critical sectors like renewable energy and power transmission, where THD minimization is crucial.

23 November 2020 in Electronics
Verified
Journal Article
Open access
PDF file
Oscar Rodríguez BenítezOscar Rodríguez Benítez
Oscar Rodríguez Benítez
Mario Ponce-SilvaMario Ponce-Silva
Mario Ponce-Silva
Juan AquiJuan Aqui
Juan Aqui
Abraham SanchezAbraham Sanchez
Abraham Sanchez
LVLuis Gerardo Vela-Valdés
Luis Gerardo Vela-Valdés
Claudia Cortes-GarciaClaudia Cortes-Garcia
Claudia Cortes-Garcia
This paper focuses on the main reasons of low efficiency in a current-fed DC-DC resonant converter applied to photovoltaic (PV) isolated systems, comparing the effects derived by the overlapping time in the gate-signals (gate-source voltage) combining silicon (Si), silicon carbide (SiC), and gallium nitride (GaN)-based power devices. The results show that unidirectional switches (metal–oxide–semiconductor field-effect transistors (MOSFETs) plus diode) present hard switching as a result of the diode preventing the MOSFET capacitance of being discharged. The effectiveness of the converter was verified with a 200-W prototype with an input voltage range of 0–30.3 V, an output voltage of 200 V, and a switching frequency of 200 kHz. The reduction losses by applying GaN versus Si and SiC technologies are 66.49% and 53.57%, respectively. Alternatively, by applying SiC versus Si devices the reduction loss is 27.84%. Finally, according to the results, 60% of losses were caused by the diodes on both switches.