Extractive distillation with salts, unlike other dehydration technologies, is better due to the null toxicity that exists in the distillate, since salt cannot be evaporated. With this distillation technology, it is possible to obtain a high concentration of ethanol, however, there are still problems in the control of the distillation columns in the presence of disturbances. The present work deals with the simulation and control of an extractive distillation column using CaCl as a separating agent, for which the Aspen Dynamics® simulator is used. The measurement and control of the ethanol composition are carried out by means of temperature, in addition, four control structures are evaluated and compared. These structures are L, D, LV, and DV, which are the most common in conventional distillation, and their performance is measured by means of deterministic indicators applying changes (disturbances) of composition and the flow rate in the main feed of the column. The most relevant results of this work lead to the fact that by applying a controller, it is possible to maintain the desired purity above the international purity standards (99% ethanol) that govern biofuels.
New biofuels are in demand and necessary to address the climate problems caused by the gases generated by fossil fuels. Biohydrogen, which is a clean biofuel with great potential in terms of energy capacity, is currently impacting our world. However, to produce biohydrogen, it is necessary to implement novel processes, such as Pressure Swing Adsorption (PSA), which raise the purity of biohydrogen to 99.99% and obtain a recovery above 50% using lower energy efficiency. This paper presents a PSA plant to produce biohydrogen and obtain a biofuel meeting international criteria. It focuses on implementing controllers on the PSA plant to maintain the desired purity stable and attenuate disturbances that affect the productivity, recovery, and energy efficiency generated by the biohydrogen-producing PSA plant. Several rigorous tests were carried out to observe the purity behavior in the face of changes in trajectories and combined perturbations by considering a discrete observer-based LQR controller compared with a discrete PID control system. The PSA process controller is designed from a simplified model, evaluating its performance on the real nonlinear plant considering perturbations using specialized software. The results are compared with a conventional PID controller, giving rise to a significant contribution related to a biohydrogen purity stable (above 0.99 in molar fraction) in the presence of disturbances and achieving a recovery of 55% to 60% using an energy efficiency of 0.99% to 7.25%.
Pressure swing adsorption (PSA) technology is used in various applications. PSA is a cost-effective process with the ability to produce high-purity bio-hydrogen (99.99%) with high recovery rates. In this article, a PSA process for the production of bio-hydrogen is proposed; it uses two columns packed with type 5A zeolite, and it has a four-step configuration (adsorption, depressurization, purge, and repressurization) for bio-hydrogen production and regeneration of the beds. The aim of this work is to design and use an active fault-tolerant control (FTC) controller to raise and maintain a stable purity of 0.9999 in molar fraction (99.99%), even with the occurrence of actuator faults. To validate the robustness and performance of the proposed discrete FTC, it has been compared with a discrete PID (proportional–integral–derivative) controller in the presence of actuator faults and trajectory changes. Both controllers achieve to maintain stable purity by reducing the effect of faults; however, the discrete PID controller is not robust to multiple faults since the desired purity is lost and fails to meet international standards to be used as bio-fuel. On the other hand, the FTC scheme reduces the effects of individual and multiple faults by striving to maintain a purity of 0.9999 in molar fraction and complying with international standards to be used as bio-fuel.
This paper addresses the challenge of evaluating control structures for a salt extractive distillation column producing absolute ethanol for use as biofuel. A sensitivity analysis aided with designing a pseudo-binary distillation pilot plant and examining the conceived process and the influence of the reflux ratio on both product purity and energy consumption. We compare three control structures for inferential tracking of the distillate composition: a dual-temperature control with an RV (reflux/boilup) structure and two single-end temperature control configurations, and their performance is measured using deterministic indicators. The result is the proposal of a pilot plant design for treating 15 kg/h of a diluted mixture with mole fraction of ethanol equal to 0.2 and assuming a column efficiency of 50%. The R/F (reflux to feed ratio) configuration is the best control structure, given that its corresponding performance indicators conduct lowest steady-state errors, less oscillating responses, and reduced settling times. For this configuration, the reflux flow rate is rationed to the feed flow rate, and the temperature is controlled manipulating the distillate flow rate. Even subject to perturbations, the energy consumption of the plant remains close to the nominal value. The three evaluated control structures consistently met international quality standards for fuel ethanol and enhanced the use of salts in ethanol dehydration.
This paper introduces a new approach to controlling Pressure Swing Adsorption (PSA) using a neural network controller based on a Model Predictive Control (MPC) process. We use a Hammerstein–Wiener (HW) model representing the real PSA process data. Then, we design an MPC-controlled model based on the HW model to maintain the bioethanol purity near molar fraction. This work proposes an Artificial Neural Network (ANN) that captures the dynamics of the PSA model controlled by the MPC strategy. Both controllers are validated using the HW model of the PSA process, showing great performance and robustness against disturbances. The results show that we can follow the desired trajectory and attenuate disturbances, achieving the purity of bioethanol at a molar fraction value of 0.99 using the ANN based on the MPC strategy with of fit in the control signal and a fit in the purity signal, so we can conclude that our ANN can be used to attenuate disturbances and maintain purity in the PSA process.
This paper shows the implementation of the Moth–Flame Optimization algorithm in a Cascade-H multilevel inverter with five and seven levels to determine the optimal switching sequence of the inverter’s semiconductor devices. The algorithm was coded in Matlab software, and the obtained switching sequences were implemented in a Cascade-H multilevel inverter laboratory prototype, where the output voltage waveform was obtained using a digital oscilloscope. The experimental Total Harmonic Distortion was obtained using a power quality analyzer. The experimental results show the improvement of the Total Harmonic Distortion in the voltage output. These results were compared with other papers in the literature with different metaheuristic methods concerning the same modulation. These findings demonstrate the feasibility of employing the Moth–Flame Optimization Algorithm to significantly reduce the Total Harmonic Distortion, obtaining a lower value than most analyzed papers.