Yue Pan

Dr. Yue Pan


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
MLMeiying Liu
Meiying Liu
HWHu Wang
Hu Wang
HYHongwei Yi
Hongwei Yi
YXYaoke Xue
Yaoke Xue
DWDesheng Wen
Desheng Wen
YPYue Pan
Yue Pan
This paper focuses on the opportunity to use multiple star trackers to help space situational awareness and space surveillance. Catalogs of space debris around Earth are usually based on ground-based measurements, which rely on data provided by ground-based radar observations and ground-based optical observations. However, space-based observations offer new opportunities because they are independent of the weather and the circadian rhythms to which the ground system is subjected. Consequently, space-based optical observations improve the possibility of space debris detection and cataloging. This work deals with a feasibility study of an innovative strategy, which consists of the use of a star sensor with a dedicated algorithm to run directly on board. This approach minimizes the impact on the original mission of the satellite, and on this basis, it has also the function of space debris monitoring. Therefore, theoretically, every satellite with a star tracker can be used as a space surveillance observer. In this paper, we propose a multi-star space debris detecting and positioning method with constant geocentric observation. Using the multi-star tracker joint positioning method, the angle measurement data of the star tracker is converted into the spatial coordinates of the target. In addition, the Gaussian MMSE difference correction algorithm is used to realize the target positioning of multiple optical observations, and the spatial target position information of the multi-frame images is fused, thus completing the solution of the orbit equation. The simulation results show that the proposed method is sufficient to detect and position space debris. It also demonstrates the necessity and feasibility of cooperative network observation by multiple star trackers.

14 April 2021 in Electronics
Verified
Journal Article
Open access
PDF file
YPYue Pan
Yue Pan
XFXuewu Fan
Xuewu Fan
HWHu Wang
Hu Wang
HZHui Zhao
Hui Zhao
YQYulei Qiu
Yulei Qiu
JZJian Zhang
Jian Zhang
The signal-variance method and the photon transfer curve method are the most valuable tools for calculating the conversion gains of charge-coupled device (CCD) detectors. This paper describes the phenomena that arise in the conversion gain measurements of space multi-band variable object monitor (SVOM) visible telescope (VT) CCDs, where the results of the signal-variance method increase with the image gray level, and the results of the photon transfer curve method appear with nonlinearity, which is caused by the signal-dependent charge sharing mechanism of back-illuminated CCDs. A numerical simulation model based on random variables was adopted to analyze the influence of the mechanism on the gain determination. The model simulates all the signals and noise in the flat field image, including the photon signal and photon-shot noise, readout noise, fixed pattern noise, and the signal-dependent charge-sharing signal, and it demonstrated agreement with the experimental data. Then, we proposed a quadratic polynomial curve-fitting formula for the photon transfer curve, and we quantitatively analyzed the relationship between the fitting coefficients and the gain, the signal-dependent charge sharing coefficient, and the full well capacity using the control variable method. Finally, the formula was used to accurately determine the conversion gains of SVOM VT CCDs.

1 March 2022 in Publications of the Astronomical Society of the Pacific
Verified
Journal Article
Closed access
YPYue Pan
Yue Pan
The Visible Telescope (VT), which is the primary payload for the Chinese-French Space Multi-band Variable Object Monitor (SVOM) mission, is designed to observe the optical afterglow of gamma-ray bursts (GRBs). While calibration is one of the key factors to validate that VT achieves its scientific objectives in terms of detection limit, photometric accuracy and photometric system deviation. In the dissertation, based on the scientific objectives and optomechanical parameters of SVOM VT, the calibration techniques for space-based astronomical telescopes are studied. We have carried out comprehensive characterization and high-precision calibration of VT qualification model in three phases: detector, instrumentation and in-orbit laboratory verification, and all tests have reached the desired results and meet the requirements of calibration indicators.

20 April 2021 in Photonics
Verified
Journal Article
Open access
PDF file
YPYue Pan
Yue Pan
XFXuewu Fan
Xuewu Fan
HZHui Zhao
Hui Zhao
YQYulei Qiu
Yulei Qiu
WGWei Gao
Wei Gao
JZJian Zhang
Jian Zhang
This paper describes a fast technique for estimating the dark signals of the charge coupled devices (CCDs) of the visible telescope (VT) onboard the space multi-band variable object monitor (SVOM). It is based on the vertical gradient in the dark field images of the frame transfer CCDs. During the process of frame clear, exposure, frame transfer and readout, the characteristic of dark signal accumulation is analyzed firstly. Next, the linear fitting method is used to fit the signal level of the dark field image in the vertical direction, and the slope of the fitting line represents the dark signal factor. This technique only needs one dark field image and can be used for simple and efficient dark signal measurements of frame transfer CCDs. Besides, an experiment of detecting dark signals as a function of temperature based on the fast technique has been carried out. Making use of the Shockley-Hall-Read theory, two curve fitting formulas are adopted to the experimental results for VT Advanced Inverted Mode Operation (AIMO) CCD and VT Non-Inverted Mode Operation (NIMO) CCD respectively. The experimental results and the formulas are used to determine the optimal on-orbit cooling temperature of VT CCDs.

14 June 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
FWFang Wang
Fang Wang
XFXuewu Fan
Xuewu Fan
HWHu Wang
Hu Wang
YPYue Pan
Yue Pan
SYSHEN YANG
SHEN YANG
SLShangmin Lin
Shangmin Lin
Optical instrumentation with reliable performance is essential for the research of exoplanet atmosphere characteristics. However, due to long distances and weak signals, exoplanets are difficult to be imaged by traditional optical systems. To this end, a novel optical system based on transit spectroscopy is proposed in this paper. On the basis of the principle of the transit-spectroscopy method and the astronomical parameters of observed targets, the optional parameter ranges of a dedicated optical system are analyzed. The transit signal-to-noise ratio (SNR) is introduced for the determination of telescope aperture and throughput. Furthermore, an example of the optical system with a space telescope and spectrometer is proposed according to the above optical index, which is proven to meet the performance requirements. The optical system is required to cover the wavelength of 0.5–8 μm and the field of view (FOV) of 27.9″ within the diffraction limit. The collecting aperture should be greater than 2 m, and spectral resolutions of two spectrometer channels should approximately be 100 (2–4 μm) and 30 (4–8 μm). The point-spread function (PSF) of each channel at the minimal wavelength should cover 2 pixels. The telescope and dichroic system provide diffraction-limited input beams with the required aperture, FOV, and wavelength for the spectrometer slits. The simulation results of the optical system show that the spectral resolutions of the dual-channel spectrometer were 111–200 and 43–94. The image points of the spectrometer in each wavelength were smaller than the Airy spot within the slit FOV, and the full width at half-maximum (FWHM) of PSF at λmin provided 2 pixels of 18 μm sampling. The feasibility of the demonstrated optical parameters is proven by the design.

3 August 2023 in Preprints.org
Verified
Preprint
Open access
PDF file
YLYang Liu
Yang Liu
YXYaoke Xue
Yaoke Xue
HWHu Wang
Hu Wang
YPYue Pan
Yue Pan
SLShangmin Lin
Shangmin Lin
JLJie Liu
Jie Liu
In light of the current situation where no testing equipment is available for measuring thermal deformation of objects, this paper proposes a novel method for accurate and precise measurement. The method overcomes the limitations of previous approaches that relied on pitch angle. By utilizing the principle of biplane multiple reflections, a bivariate laser spot displacement analysis algorithm is devised to attain highly precise measurements of bivariate angles. Additionally, a temperature gradient comparison algorithm is introduced to calculate the indicator test results under specific temperature conditions. To validate the effectiveness and reliability of this method, a testing system is constructed and utilized. The results demonstrate that the thermal deformation angle change test achieves an impressive accuracy of 0.015″ and a rate of thermal deformation angle change of 0.3247″/°C. These values are in close agreement with the previously simulated analysis result of 0.359″/°C, with only a relative error of 9.55%. Therefore, the test results confirm the efficacy and reliability of this testing method along with the feasibility of the algorithm processing.