27 January 2023 in Water
Verified
Journal Article
Open access
PDF file
AAAskar Abdykadyrov
Askar Abdykadyrov
Sunggat MarxulySunggat Marxuly
Sunggat Marxuly
Ainur KuttybayevaAinur Kuttybayeva
Ainur Kuttybayeva
Nurgul AlmuratovaNurgul Almuratova
Nurgul Almuratova
MYMuratbek Yermekbayev
Muratbek Yermekbayev
YBYessen Bagdollauly
Yessen Bagdollauly
In this scientific work, the problem of studying the process of destruction of microorganisms in water by an Etro-03 device based on electric corona discharge is considered. In the research, a special Etro-03 ozonator device was developed for clearing water of biological pollutants. Testing of the installation was carried out in order to disinfect surface water in the Kapshagai reservoir. During the research, various harmful microorganisms were found in the composition of the primary water that did not meet the maximum permissible concentration (MPC). For example, coliphages, coli-indices, and the number of microbes in general came across in large numbers. During the technological process, various amounts of ozone (O3) were released into the water, the amount and effective economic indicators of which were determined. In the same way, the effective time of the decontamination process was determined. During the research process, an algorithm of theoretical calculations was developed, and a mathematical model was given to bring 1m3 of surface water as the indicator for which sanitary rules and norms are approved.

14 July 2021 in Electronics
Verified
Journal Article
Open access
PDF file
VPVictor Petrushin
Victor Petrushin
VHVasily Horoshko
Vasily Horoshko
JPJuriy Plotkin
Juriy Plotkin
Nurgul AlmuratovaNurgul Almuratova
Nurgul Almuratova
Жанар ТойгожиноваЖанар Тойгожинова
Жанар Тойгожинова
In this study, power quality coefficients that determine the distortion of electrical systems are established. The power factor is chosen as a universal criterion for electromagnetic and electro-energetic compatibility of distorted sources and distorting loads. Mathematical expressions are obtained for its calculation in various cases of electrical systems distortion. As an application example, power balances and power factors of a variable frequency asynchronous drive system are considered. The criterion: the power factor not only determines the energy and electromagnetic compatibility of the drive with power supply, but it also evaluates drive efficiency. Experimental studies were carried out under usage of inexpensive, commonly used measuring devices both on the grid side of the frequency converter and on the asynchronous motor side. The studied coefficients were determined in two ways: measuring instruments and analysis of oscillograms. The second method for determining the above coefficients from oscillograms of currents and voltages also requires finding the total harmonic distortion (THD) of currents and voltages for the corresponding load adjusting points. The similarity of the obtained results shows that both of these methods can be applied. According to the operating mode of the load, the criterion is calculated as an average range in a certain range of speed control, or it is determined by considering a given tachogram of speed changes. The results of experimental studies confirm the correctness of the theoretical provisions.

9 December 2025 in Water
Verified
Journal Article
Open access
PDF file
Nurgul AlmuratovaNurgul Almuratova
Nurgul Almuratova
ADAkerke Dyussenbiyeva
Akerke Dyussenbiyeva
MZMakpal Zharkymbekova
Makpal Zharkymbekova
ENElmira Nurmadiyeva
Elmira Nurmadiyeva
NKNurlan Kystaubayev
Nurlan Kystaubayev
AAAskar Abdykadyrov
Askar Abdykadyrov
The object of this research is the process of water disinfection by means of high-frequency electrical discharge. The study addresses the problem of achieving high biological efficiency while reducing energy consumption and avoiding harmful by-products typical of traditional methods such as chlorination or UV irradiation. As a result, a comprehensive theoretical and experimental investigation was conducted, demonstrating that within 20 s of plasma exposure, E. coli, S. aureus, and P. aeruginosa bacteria were inactivated by 99.2–99.9%. The observed efficiency is explained by the synergistic action of reactive oxygen and nitrogen species (•OH, O3, H2O2, NO2−, NO3−) formed in the plasma–water interface. The distinctive features of the obtained results include the establishment of optimal operating parameters-voltage U = 12–18 kV, frequency f ≈ 35 kHz, and gap distance d = 15 mm—under which the normalized specific energy input (SEI) was 6–9 kWh per cubic meter of water. This value represents the standard normalization used for plasma-based treatment systems, where the electrical energy delivered to the reactor is divided by the treated volume (1.0 L in our setup) and scaled to m3 for comparison with other studies, 30–40% lower than in previously reported plasma systems. The validated physicochemical model (Poisson, Navier–Stokes, and continuity equations) matched experimental data with R2 ≥ 0.95, confirming its predictive capability for further scale-up. The practical significance of the results lies in the potential application of this method for decentralized and industrial water treatment systems. The reagent-free, energy-efficient, and environmentally safe nature of the proposed approach makes it suitable for sustainable water purification under real operating conditions.

9 September 2021 in Journal of Vibroengineering
Verified
Journal Article
Open access
PDF file
NDNazira Darimbaeva
Nazira Darimbaeva
MMMarat Mustafin
Marat Mustafin
Nurgul AlmuratovaNurgul Almuratova
Nurgul Almuratova
AZAlgazy Zhauyt
Algazy Zhauyt
A mathematical model of a frequency-controlled induction (asynchronous) electric drive is proposed, which makes it possible to study electromagnetic and electromechanical processes in an electric drive with any drive mechanism and takes into account the non-sinusoidality of the output voltage of the frequency converter. The block diagram of the algorithms of calculations performed in the “Mathcad” computer application, the results of modeling and their analysis are presented.

30 July 2023 in Energies
Verified
Journal Article
Open access
PDF file
VPVictor Petrushin
Victor Petrushin
JPJuriy Plotkin
Juriy Plotkin
Nurgul AlmuratovaNurgul Almuratova
Nurgul Almuratova
MMMarat Mustafin
Marat Mustafin
MZMakpal Zharkymbekova
Makpal Zharkymbekova
A range criterion of discounted costs is proposed, which takes into account all costs for a speed-controlled asynchronous electric drive, including its price, costs of losses and maintenance, and amortization charges. It is also possible to take into account the cost and energy performance of matching transformers and gearboxes. Costs for reactive power compensation of both the first and second kind (due to the presence of harmonic components at the drive input) are taken into account. The latter requires determining the total harmonic distortion (THD) of the currents consumed by the drive. In the case of autonomous power systems, it is also necessary to determine the drive’s supplying voltage non-linear distortion coefficients. Representing the discounted costs as the sum of initial capital investments and annual costs made possible taking into account the presence of inflationary processes. The control characteristics of the active power consumed by the drive, efficiency, power factor, and phase shift factor are constructed, which are dependencies on the rotation frequency in a certain control range at a specific load. It is proposed to calculate the drive’s discounted costs criterion, depending on the operating mode of the load. According to the mode, the criterion is calculated as an average range in a certain range of speed control or is determined taking into account a given tachogram of speed changes. For the controlled asynchronous drive under consideration, the discounted costs are 4148 c.u. in the first case and 5139.3 c.u. in the second case. If inflationary processes are taken into account, the first case is 4219.4 c.u. and the second case is 5227.7 c.u., respectively.

19 March 2021 in Energies
Verified
Journal Article
Open access
PDF file
JPJuriy Plotkin
Juriy Plotkin
Nurgul AlmuratovaNurgul Almuratova
Nurgul Almuratova
Assel YerzhanAssel Yerzhan
Assel Yerzhan
VPVictor Petrushin
Victor Petrushin
Precise torque control without pulsations is one of the major quality issues in pulse-width modulated voltage-source inverter (PWM-VSI) drives. Theoretically, it could be postulated that at frequencies of some kHz, the machine’s inertia absorbs switching frequency torque harmonics, and the resulting torque becomes smooth; though, in reality, parasitic effects in voltage source inverters may cause additional torque harmonics of low order. In particular, first, second and sixth torque harmonics are observed. Such torque harmonics are especially dangerous for normal drive operation, since they may be amplified by drive train resonances at corresponding rotational velocities. New parasitic effects in PWM-VSI control, leading to torque harmonic of low order, are described in the paper, and recommendations for their compensation are given.