Nurlan Kystaubayev

Mr. Nurlan Kystaubayev

orcid

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 June 2025 in Eastern-European Journal of Enterprise Technologies
Verified
Journal Article
Open access
PDF file
AAAskar Abdykadyrov
Askar Abdykadyrov
MAMukhit Abdullayev
Mukhit Abdullayev
Ainur KuttybayevaAinur Kuttybayeva
Ainur Kuttybayeva
KTKalmukhamed Tazhen
Kalmukhamed Tazhen
NKNurlan Kystaubayev
Nurlan Kystaubayev
NSNurlan Sarsenbayev
Nurlan Sarsenbayev
The object of the study is the methods of radio frequency resource management in stratospheric communication systems based on high altitude platform stations (HAPS). The problem addressed is the limited radio frequency spectrum, frequency overlap with fifth- and sixth-generation (5G/6G) networks, and the high probability of interference, which complicate efficient spectrum utilization and coordination. The obtained results indicate that within the frequency bands recommended by the International Telecommunication Union (ITU) — 21.4–22.0 GHz, 24.25–27.5 GHz, 47.2–47.5 GHz, and 47.9–48.2 GHz — the probability of interference reaches up to 70% in the 27.5–28.35 GHz band. By applying cognitive radio (CR) technology, interference levels decreased by 60%, and spectrum utilization efficiency increased by 35%. Dynamic spectrum access (DSA) improved spectrum efficiency by 30–45%, while spectrum sharing methods enhanced it by 40–60%. A brief explanation of the results shows that the proposed management approaches significantly increase the efficiency of radio frequency resource use and substantially reduce interference. For example, at a bandwidth of 100 MHz and a signal-to-noise ratio (SNR) of 10, the channel capacity reached approximately 332 Mbps. The distinctive features of the results lie in the comprehensive use of modern technologies that effectively address spectrum scarcity and interference issues, ensuring compatibility of HAPS with existing terrestrial and satellite communication systems. The proposed approaches are suitable for implementation in international and national spectrum coordination and licensing frameworks aimed at expanding broadband connectivity in underserved regions

3 March 2026 in Fibers
Verified
Journal Article
Open access
PDF file
AAAskar Abdykadyrov
Askar Abdykadyrov
Amandyk K. TuleshovAmandyk K. Tuleshov
Amandyk K. Tuleshov
Nurzhigit SmailovNurzhigit Smailov
Nurzhigit Smailov
ZDZhandos Makhsutuly Dosbayev
Zhandos Makhsutuly Dosbayev
Sunggat MarxulySunggat Marxuly
Sunggat Marxuly
NKNurlan Kystaubayev
Nurlan Kystaubayev
In recent decades, the reliability and safety of large engineering structures have become a critical issue due to failures caused by undetected micro-level deformations. Fiber-optic strain sensors, especially Fiber Bragg Grating (FBG) and interferometric systems, are widely used in structural health monitoring (SHM); however, their standard sensitivity is often insufficient for early detection of nano-strain level damage. This paper presents a comparative analysis and system-level optimization of the main sensitivity enhancement methods, including mechanical amplification, functional coatings and composite embedding, interferometric schemes, and advanced spectral signal processing. Analytical modeling and numerical simulations were performed. It is shown that flexure-beam amplifiers provide a stable sensitivity gain of 2.1–4.8, whereas lever-type mechanisms achieve higher amplification (5.6–9.3) at the cost of dynamic degradation. Functional coatings increase the strain transfer coefficient from 0.62 to 0.68 to 0.91–0.97, but introduce temperature-induced errors up to 1.5–2.0 µε. Interferometric systems can detect strains at the 10−8 level but exhibit high temperature cross-sensitivity. Advanced spectral processing reduces the Bragg wavelength estimation error by 8–15 times, improving the equivalent strain resolution to (2–5) × 10−8. Based on these results, an optimized integrated approach combining moderate mechanical amplification (2.5–3.5), improved strain transfer (η ≈ 0.85–0.92), and efficient spectral processing is proposed. This improves the equivalent strain resolution from 1 × 10−6 to (1.5–3.0) × 10−8 while keeping temperature-induced errors within 15–25% and limiting the computational load increase to 2–3 times. The proposed solution is suitable for long-term monitoring of large engineering structures.

9 December 2025 in Water
Verified
Journal Article
Open access
PDF file
Nurgul AlmuratovaNurgul Almuratova
Nurgul Almuratova
ADAkerke Dyussenbiyeva
Akerke Dyussenbiyeva
MZMakpal Zharkymbekova
Makpal Zharkymbekova
ENElmira Nurmadiyeva
Elmira Nurmadiyeva
NKNurlan Kystaubayev
Nurlan Kystaubayev
AAAskar Abdykadyrov
Askar Abdykadyrov
The object of this research is the process of water disinfection by means of high-frequency electrical discharge. The study addresses the problem of achieving high biological efficiency while reducing energy consumption and avoiding harmful by-products typical of traditional methods such as chlorination or UV irradiation. As a result, a comprehensive theoretical and experimental investigation was conducted, demonstrating that within 20 s of plasma exposure, E. coli, S. aureus, and P. aeruginosa bacteria were inactivated by 99.2–99.9%. The observed efficiency is explained by the synergistic action of reactive oxygen and nitrogen species (•OH, O3, H2O2, NO2−, NO3−) formed in the plasma–water interface. The distinctive features of the obtained results include the establishment of optimal operating parameters-voltage U = 12–18 kV, frequency f ≈ 35 kHz, and gap distance d = 15 mm—under which the normalized specific energy input (SEI) was 6–9 kWh per cubic meter of water. This value represents the standard normalization used for plasma-based treatment systems, where the electrical energy delivered to the reactor is divided by the treated volume (1.0 L in our setup) and scaled to m3 for comparison with other studies, 30–40% lower than in previously reported plasma systems. The validated physicochemical model (Poisson, Navier–Stokes, and continuity equations) matched experimental data with R2 ≥ 0.95, confirming its predictive capability for further scale-up. The practical significance of the results lies in the potential application of this method for decentralized and industrial water treatment systems. The reagent-free, energy-efficient, and environmentally safe nature of the proposed approach makes it suitable for sustainable water purification under real operating conditions.

3 February 2026 in Energies
Verified
Journal Article
Open access
PDF file
AAAskar Abdykadyrov
Askar Abdykadyrov
YKYerkin Khidolda
Yerkin Khidolda
ABAmangeldy Bekbayev
Amangeldy Bekbayev
YSYerlan Sarsenbayev
Yerlan Sarsenbayev
NKNurlan Kystaubayev
Nurlan Kystaubayev
DMDurdona Mustafoeva
Durdona Mustafoeva
This study develops an intelligent real-time diagnostic and forecasting model for photovoltaic (PV) stations operating in the rural regions of Kazakhstan. Field measurements show that in Kazakhstan’s rural conditions, daily temperature fluctuations of 18–27 °C reduce PV output by 10–15%, solar irradiance variations of 800–1100 W/m2 cause an additional 8–12% deviation, and mineral-rich dust accumulation of 20–120 μm results in 3–5% power loss per 10 μm layer. Using the Beer–Lambert–Bouguer law, thermal degradation coefficients, and inverter droop models, the physical–mathematical behavior of PV degradation was described. The hybrid AI model (LSTM + XGBoost + Random Forest) achieved 89–91% accuracy in 24 h forecasting and 88–93% accuracy in fault detection. Overall, the proposed system reduces energy losses by 10–15% and shortens maintenance time by 18–24%, improving the reliability of rural PV stations in Kazakhstan.

17 March 2026 in Designs
Verified
Journal Article
Open access
PDF file
AAAskar Abdykadyrov
Askar Abdykadyrov
Amandyk K. TuleshovAmandyk K. Tuleshov
Amandyk K. Tuleshov
Nurzhigit SmailovNurzhigit Smailov
Nurzhigit Smailov
ZDZhandos Makhsutuly Dosbayev
Zhandos Makhsutuly Dosbayev
Sunggat MarxulySunggat Marxuly
Sunggat Marxuly
NKNurlan Kystaubayev
Nurlan Kystaubayev
This study presents the engineering design and system-level modeling of a high-frequency power supply architecture for electrostatic precipitators intended to improve particulate removal efficiency and operational stability. Atmospheric air pollution by fine particulate matter (PM2.5) remains one of the most critical challenges in environmental protection and public health. Although electrostatic precipitators (ESPs) are widely used for industrial gas cleaning, the efficiency and stability of conventional 50 Hz power supplies are limited under conditions of strongly nonlinear corona discharge and high-resistivity dust. This paper presents the development and investigation of an advanced high-frequency power supply system for electrostatic precipitators based on a coupled electrical–electrophysical mathematical model. The work follows an engineering design methodology that integrates converter topology selection, electrophysical modeling of corona discharge, and control-oriented system optimization. The proposed model provides a unified description of electric field formation, space charge accumulation, ion transport, and particle motion in the corona discharge region. The simulation results show that in the operating voltage range of 10–100 kV, the electric field strength reaches (2–5)·106 V/m, the ion concentration stabilizes in the range of 1013–1015 m−3, and the particle drift velocity increases from approximately 0.05 to 0.3 m/s, leading to an increase in collection efficiency from about 55% to 93%. It is demonstrated that the proposed system ensures stable output voltage regulation within ±2.5–5% even under strongly nonlinear load conditions. The use of an LC output filter (C = 1–10 nF, L = 10–100 mH) reduces the voltage ripple from about 14% to 1.4–4.8% and significantly improves the transient response. In addition, adaptive adjustment of the pulse repetition frequency in the range of 10–200 kHz makes it possible to reduce energy consumption by 12–18% while simultaneously increasing the collection efficiency by 8–15%. The obtained results confirm that the proposed high-frequency power supply architecture provides a physically well-founded and energy-efficient solution for improving the environmental performance and operational stability of electrostatic precipitators.

10 March 2026 in Network
Verified
Journal Article
Open access
PDF file
AAAskar Abdykadyrov
Askar Abdykadyrov
MKMoldir Kuatova
Moldir Kuatova
Nurzhigit SmailovNurzhigit Smailov
Nurzhigit Smailov
ZDZhandos Makhsutuly Dosbayev
Zhandos Makhsutuly Dosbayev
Sunggat MarxulySunggat Marxuly
Sunggat Marxuly
Amirkhan BekmurzaAmirkhan Bekmurza
Amirkhan Bekmurza
This study investigates radio-frequency signal propagation in underground metro tunnels with a focus on distributed antenna system (DAS) deployment. Deterministic simulations were performed using Altair WinProp 2024.1 (ProMan) with a 3D ray-tracing engine (GO + UTD) at 2.4 GHz in a reinforced concrete tunnel model of 900 m length. Two antenna configurations (B3: 8 dBi directional; B8: 5 dBi wide-beam) were evaluated under identical geometric and material conditions. Results show that path loss varies from 42 to 65 dB over 850 m, with estimated attenuation exponents lower than free-space values due to quasi-waveguide effects. The B3 configuration provides higher near-field received power (up to −7.5 dBm) but exhibits stronger attenuation over long distances. In contrast, the B8 configuration ensures a more uniform spatial power distribution and a reduced path-loss growth rate beyond 500 m. The findings confirm that antenna radiation pattern significantly influences underground communication performance and demonstrate the engineering suitability of distributed antenna systems for stable metro tunnel coverage.