Maeruan Kebbach

Mr. Maeruan Kebbach

Department of Orthopaedics, Rostock University Medical Center
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 March 2021 in Medical Engineering & Physics
Verified
Journal Article
Open access
COChristoph Oefner
Christoph Oefner
SHSven Herrmann
Sven Herrmann
MKMaeruan Kebbach
Maeruan Kebbach
HLHans-E. Lange
Hans-E. Lange
DKDaniel Kluess
Daniel Kluess
MWMatthias Woiczinski
Matthias Woiczinski
Finite element analysis (FEA) has become a fundamental tool for biomechanical investigations in the last decades. Despite several existing initiatives and guidelines for reporting on research methods and results, there are still numerous issues that arise when using computational models in biomechanical investigations. According to our knowledge, these problems and controversies lie mainly in the verification and validation (V&V) process as well as in the set-up and evaluation of FEA. This work aims to introduce a checklist including a report form defining recommendations for FEA in the field of Orthopedic and Trauma (O&T) biomechanics. Therefore, a checklist was elaborated which summarizes and explains the crucial methodologies for the V&V process. In addition, a report form has been developed which contains the most important steps for reporting future FEA. An example of the report form is shown, and a template is provided, which can be used as a uniform basis for future documentation. The future application of the presented report form will show whether serious errors in biomechanical investigations using FEA can be minimized by this checklist. Finally, the credibility of the FEA in the clinical area and the scientific exchange in the community regarding reproducibility and exchangeability can be improved.

13 May 2019 in Computer Methods in Biomechanics and Biomedical Engineering
Verified
Journal Article
Closed access
DKDaniel Kluess
Daniel Kluess
ESEhsan Soodmand
Ehsan Soodmand
ALAndrea Lorenz
Andrea Lorenz
DPDieter Pahr
Dieter Pahr
MSMichael Schwarze
Michael Schwarze
MKMaeruan Kebbach
Maeruan Kebbach
Finite element analysis is a common tool that has been used for the past few decades to predict the mechanical behavior of bone. However, to our knowledge, there are no round-robin finite element analyses of long human bones with more than two participating biomechanics laboratories published yet, where the results of the experimental tests were not known in advance. We prepared a fresh-frozen human femur for a compression test in a universal testing machine measuring the strains at 10 bone locations as well as the deformation of the bone in terms of the displacement of the loading point at a load of 2 kN. The computed tomography data of the bone with a calibration phantom as well as the orientation of the bone in the testing machine with the according boundary conditions were delivered to seven participating laboratories. These were asked to perform a finite element analysis simulating the experimental setup and deliver their results to the coordinator without knowing the experimental results. Resultantly, four laboratories had deviations from the experimentally measured strains of less than 40%, and three laboratories had deviations of their numerically determined values compared to the experimental data of more than 120%. These deviations are thought to be based on different material laws and material data, as well as different material mapping methods. Investigations will be conducted to clarify and assess the reasons for the large deviations in the numerical data. It was shown that the precision of finite element models of the human femur is not yet as developed as desired by the biomechanics community.

1 January 2021 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Closed access
DVDanny Vogel
Danny Vogel
MWMerle Wehmeyer
Merle Wehmeyer
MKMaeruan Kebbach
Maeruan Kebbach
HHHorst Heyer
Horst Heyer
RBRainer Bader
Rainer Bader

21 May 2020 in Materials
Verified
Journal Article
Open access
PDF file
MKMaeruan Kebbach
Maeruan Kebbach
MDMartin Darowski
Martin Darowski
SKSven Krüger
Sven Krüger
CSChristoph Schilling
Christoph Schilling
TGThomas M. Grupp
Thomas M. Grupp
AGAndreas Geier
Andreas Geier
Patellofemoral (PF) disorders are considered a major clinical complication after total knee replacement (TKR). Malpositioning and design of the patellar component impacts knee joint dynamics, implant fixation and wear propagation. However, only a limited number of studies have addressed the biomechanical impact of the patellar component on PF dynamics and their results have been discussed controversially. To address these issues, we implemented a musculoskeletal multibody simulation (MMBS) study for the systematical analysis of the patellar component’s thickness and positioning on PF contact forces and kinematics during dynamic squat motion with virtually implanted unconstrained cruciate-retaining (CR)-TKR. The patellar button thickness clearly increased the contact forces in the PF joint (up to 27%). Similarly, the PF contact forces were affected by superior–inferior positioning (up to 16%) and mediolateral positioning (up to 8%) of the patellar button. PF kinematics was mostly affected by the mediolateral positioning and the thickness of the patellar component. A medialization of 3 mm caused a lateral patellar shift by up to 2.7 mm and lateral patellar tilt by up to 1.6°. However, deviations in the rotational positioning of the patellar button had minor effects on PF dynamics. Aiming at an optimal intraoperative patellar component alignment, the orthopedic surgeon should pay close attention to the patellar component thickness in combination with its mediolateral and superior–inferior positioning on the retropatellar surface. Our generated MMBS model provides systematic and reproducible insight into the effects of patellar component positioning and design on PF dynamics and has the potential to serve as a preoperative analysis tool.

10 October 2019 in Scientific Reports
Verified
Journal Article
Open access
PDF file
MKMaeruan Kebbach
Maeruan Kebbach
RGR. Grawe
R. Grawe
AGA. Geier
A. Geier
EWE. Winter
E. Winter
PBP. Bergschmidt
P. Bergschmidt
RBR. Bader
R. Bader
The complicated interplay of total knee replacement (TKR) positioning and patient-specific soft tissue conditions still causes a considerable number of unsatisfactory outcomes. Therefore, we deployed a robot-assisted test method, in which a six-axis robot moved and loaded a bicondylar cruciate-retaining (CR)-TKR in a virtual lower extremity emulated by a musculoskeletal multibody model. This enabled us to systematically analyse the impact of the posterior cruciate ligament (PCL), tibial slope, and tibial component rotation on TKR function while considering the physical implant components and physiological-like conditions during dynamic motions. The PCL resection yielded a decrease of femoral rollback by 4.5 mm and a reduction of tibiofemoral contact force by 50 N. A reduced tibial slope led to an increase of tibiofemoral contact force by about 170 N and a decrease of femoral rollback up to 1.7 mm. Although a higher tibial slope reduced the contact force, excessive tibial slopes should be avoided to prevent joint instability. Contrary to an external rotation of the tibial component, an internal rotation clearly increased the contact force and lateral femoral rollback. Our data contribute to improved understanding the biomechanics of TKRs and show the capabilities of the robot-assisted test method based on a musculoskeletal multibody model as a preoperative planning tool.

27 August 2022 in Journal of Orthopaedic Research
Verified
Journal Article
Open access
TTThomas Tischer
Thomas Tischer
AGAndreas Geier
Andreas Geier
CLChristoph Lutter
Christoph Lutter
AEAndreas Enz
Andreas Enz
RBRainer Bader
Rainer Bader
MKMaeruan Kebbach
Maeruan Kebbach
The role of patella height is discussed controversially in total knee arthroplasty (TKA). Therefore, this computational study aims to systematically analyze the biomechanical effect of different patella heights on patellofemoral (PF) forces and kinematics after cruciate‐retaining (CR) TKA. We implemented a CR bicondylar TKA with a dome patellar button in a validated dynamic musculoskeletal multibody model of a male human knee joint. Retropatellar dynamics (contact force [N], shear force [N], patellar shift [mm], tilt [°], and rotation [°]) were evaluated during dual‐limb squat motion (flexion from 0° to 90°) with simulated active muscle forces and the effects of different patella heights (Blackburne‐Peel [BP] ratio of 0.39, 0.49, 0.65, 0.85, 1.01, and 1.1 were systematically examined). As active knee flexion increased, PF contact force also increased. Patella alta (BP = 1.1) resulted in higher PF contact forces compared to normal patella height (BP = 0.65) by up to 16%. Contrarily, patella baja was associated with decreased PF forces by 7%. Compared to patella baja (BP = 0.39), patella alta (BP = 1.1) considerably increased the contact force by up to 25%. Different patellar heights mainly affected PF shear forces during early knee flexion. Concerning PF kinematics, patella alta (BP = 1.1) yielded a greater lateral tilt of more than 4° and higher patellar rotation by up to 3° during deep knee flexion, compared to normal patella height (BP = 0.65). Our computational study indicates that patella alta is associated with the highest PF contact and shear force after the implantation of a CR bicondylar TKA. This should be considered in PF disorders following TKA.