Hans-E. Lange

Mr. Hans-E. Lange

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 March 2021 in Medical Engineering & Physics
Verified
Journal Article
Open access
COChristoph Oefner
Christoph Oefner
SHSven Herrmann
Sven Herrmann
MKMaeruan Kebbach
Maeruan Kebbach
HLHans-E. Lange
Hans-E. Lange
DKDaniel Kluess
Daniel Kluess
MWMatthias Woiczinski
Matthias Woiczinski
Finite element analysis (FEA) has become a fundamental tool for biomechanical investigations in the last decades. Despite several existing initiatives and guidelines for reporting on research methods and results, there are still numerous issues that arise when using computational models in biomechanical investigations. According to our knowledge, these problems and controversies lie mainly in the verification and validation (V&V) process as well as in the set-up and evaluation of FEA. This work aims to introduce a checklist including a report form defining recommendations for FEA in the field of Orthopedic and Trauma (O&T) biomechanics. Therefore, a checklist was elaborated which summarizes and explains the crucial methodologies for the V&V process. In addition, a report form has been developed which contains the most important steps for reporting future FEA. An example of the report form is shown, and a template is provided, which can be used as a uniform basis for future documentation. The future application of the presented report form will show whether serious errors in biomechanical investigations using FEA can be minimized by this checklist. Finally, the credibility of the FEA in the clinical area and the scientific exchange in the community regarding reproducibility and exchangeability can be improved.

22 October 2020 in Smart Materials and Structures
Verified
Journal Article
Open access
HLHans-E. Lange
Hans-E. Lange
DHDennis Hohlfeld
Dennis Hohlfeld
RBRainer Bader
Rainer Bader
DKDaniel Kluess
Daniel Kluess
To improve the clinical outcome of total hip replacements (THRs), instrumented implants with sensory functions for implant monitoring and diagnostics or actuators for therapeutic measures are a promising approach. Therefore, an adequate energy source is needed. Batteries and external power supplies bring shortcomings e.g. limited lifetime or dependency on external equipment. Energy harvesting has the clear benefit of providing continuous and independent power for fully autonomous implants. Our present study evaluates by means of finite element analysis (FEA) the capabilities of a concept of a piezoelectric energy harvesting system (ring shaped multilayer piezoelectric element of 5 mm diameter and 2.5 mm height) integrated in a femoral hip stem. The deformations from a modified load-bearing implant are used to generate electric power for various instrumentation purposes. Besides the expected amount of converted energy, the influence on the stress distribution of the instrumented implant is analysed. The results show that the local stress increase for the modified implant geometry does not exceed the stress of the original reference model. The maximum generated open circuit voltage of 11.9 V can be processed in standard energy harvesting circuitry whereas an average power output amounts up to 8.1 µW. In order to increase the electric power in an upcoming design optimization, a sensitivity analysis is performed to identify the most important influencing parameters with regard to power output and implant safety.

25 October 2023 in Bioengineering
Verified
Journal Article
Open access
PDF file
MSMarvin Steitz
Marvin Steitz
SZSabra Zouhair
Sabra Zouhair
MKMahamuda Badhon Khan
Mahamuda Badhon Khan
ABAlexander Breitenstein-Attach
Alexander Breitenstein-Attach
KFKatharina Fritsch
Katharina Fritsch
BSBoris Schmitt
Boris Schmitt
Biological bioprostheses such as grafts, patches, and heart valves are often derived from biological tissue like the pericardium. These bioprostheses can be of xenogenic, allogeneic, or autologous origin. Irrespective of their origin, all types are pre-treated via crosslinking to render the tissue non-antigenic and mechanically strong or to minimize degradation. The most widely used crosslinking agent is glutaraldehyde. However, glutaraldehyde-treated tissue is prone to calcification, inflammatory degradation, and mechanical injury, and it is incapable of matrix regeneration, leading to structural degeneration over time. In this work, we are investigating an alternative crosslinking method for an intraoperative application. The treated tissue‘s crosslinking degree was evaluated by differential scanning calorimetry. To confirm the findings, a collagenase assay was conducted. Uniaxial tensile testing was used to assess the tissue’s mechanical properties. To support the findings, the treated tissue was visualized using two-photon microscopy. Additionally, fourier transform infrared spectroscopy was performed to study the overall protein secondary structure. Finally, a crosslinking procedure was identified for intraoperative processing. The samples showed a significant increase in thermal and enzymatic stability after treatment compared to the control, with a difference of up to 22.2 °C and 100%, respectively. Also, the tissue showed similar biomechanics to glutaraldehyde-treated tissue, showing greater extensibility, a higher failure strain, and a lower ultimate tensile strength than the control. The significant difference in the structure band ratio after treatment is proof of the introduction of additional crosslinks compared to the untreated control with regard to differences in the amide-I region. The microscopic images support these findings, showing an alteration of the fiber orientation after treatment. For collagen-based biomaterials, such as pericardial tissue, the novel phenolic crosslinking agent proved to be an equivalent alternative to glutaraldehyde regarding tissue characteristics. Although long-term studies must be performed to investigate superiority in terms of longevity and calcification, our novel crosslinking agent can be applied in concentrations of 1.5% or 2.0% for the treatment of biomaterials.

17 June 2021 in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
Verified
Journal Article
Open access
PDF file
HLHans-E. Lange
Hans-E. Lange
RBRainer Bader
Rainer Bader
DKDaniel Kluess
Daniel Kluess
Instrumented implants are a promising approach to further improve the clinical outcome of total hip arthroplasties. For the integrated sensors or active functions, an electrical power supply is required. Energy harvesting concepts can provide autonomous power with unlimited lifetime and are independent from external equipment. However, those systems occupy space within the mechanically loaded total hip replacement and can decrease the life span due to fatigue failure in the altered implant. We previously presented a piezoelectric energy harvesting system for an energy-autonomous instrumented total hip stem that notably changes the original implant geometry. The aim of this study was to investigate the remaining structural fatigue failure strength of the metallic femoral implant component in a worst-case scenario. Therefore, the modified hip stem was tested under load conditions based on ISO 7206-4:2010. The required five million cycles were completed twice by all samples (n = 3). Additionally applied cycles with incrementally increased load levels up to 4.7 kN did not induce implant failure. In total, 18 million cycles were endured, outperforming the requirements of the ISO standard. Supplementary finite element analysis was conducted to determine stress distribution within the implant. A high stress concentration was found in the region of modification. The stress level showed an increase compared to the previously evaluated physiological loading situation and was close to the fatigue data from the literature. The stress concentration factor compared to the original geometry amounted to 2.56. The assessed stress level in accordance with the experimental fatigue testing can serve as a maximum reference value for further implant design modifications and optimisations.

8 September 2021 in Materials
Verified
Journal Article
Open access
PDF file
HLHans-E. Lange
Hans-E. Lange
NANils Arbeiter
Nils Arbeiter
RBRainer Bader
Rainer Bader
DKDaniel Kluess
Daniel Kluess
Instrumented implants can improve the clinical outcome of total hip replacements (THRs). To overcome the drawbacks of external energy supply and batteries, energy harvesting is a promising approach to power energy-autonomous implants. Therefore, we recently presented a new piezoelectric-based energy harvesting concept for THRs. In this study, the performance of the proposed energy harvesting system was numerically and experimentally investigated. First, we numerically reproduced our previous results for the physiologically based loading situation in a simplified setup. Thereafter, this configuration was experimentally realised by the implantation of a functional model of the energy harvesting concept into an artificial bone segment. Additionally, the piezoelectric element alone was investigated to analyse the predictive power of the numerical model. We measured the generated voltage for a load profile for walking and calculated the power output. The maximum power for the directly loaded piezoelectric element and the functional model were 28.6 and 10.2 µW, respectively. Numerically, 72.7 µW was calculated. The curve progressions were qualitatively in good accordance with the numerical data. The deviations were explained by sensitivity analysis and model simplifications, e.g., material data or lower acting force levels by malalignment and differences between virtual and experimental implantation. The findings verify the feasibility of the proposed energy harvesting concept and form the basis for design optimisations with increased power output.

11 June 2021 in Energies
Verified
Journal Article
Open access
PDF file
HLHans-E. Lange
Hans-E. Lange
RBRainer Bader
Rainer Bader
DKDaniel Kluess
Daniel Kluess
Energy harvesting is a promising approach to power novel instrumented implants that have passive sensory functions or actuators for therapeutic measures. We recently proposed a new piezoelectric concept for energy harvesting in total hip replacements. The mechanical implant safety and the feasibility of power generation were numerically demonstrated. However, the power output for the chosen piezoelectric element was low. Therefore, we investigated in the present study different geometry variants for an increased power output for in vivo applications. Using the same finite element model, we focused on new, customised piezoelectric element geometries to optimally exploit the available space for integration of the energy harvesting system, while maintaining the mechanical safety of the implant. The result of our iterative design study was an increased power output from 29.8 to 729.9 µW. This amount is sufficient for low-power electronics.