Phantoms of biological tissues are materials that mimic the properties of real tissues. This study shows the development of phantoms with nanodiamond particles for calibration of T1 relaxation time in magnetic resonance imaging. Magnetic resonance imaging (MRI) is a commonly used and non-invasive method of detecting pathological changes inside the human body. Nevertheless, before a new MRI device is approved for use, it is necessary to calibrate it properly and to check its technical parameters. In this article, we present phantoms of tissue with diamond nanoparticles dedicated to magnetic resonance calibration. The method of producing phantoms has been described. As a result of our research, we obtained phantoms that were characterized by the relaxation time T1 the same as the relaxation time of the human tissue T1 = 810.5 ms. Furthermore, the use of diamond nanoparticles in phantoms allowed us to tune the T1 value of the phantoms which open the way to elaborated phantoms of other tissues in the future.
22 January 2021 in Radiation and Environmental Biophysics
In recent years, a method for designing radiotherapy boluses using 3D printing technology has been established in the West Pomeranian Oncology Centre in Szczecin, Poland. The aim of the present study was to investigate whether the ionising radiation used in radiotherapy affects the physical properties of the printing material. Particularly, the purpose of this study was to determine the effect of a 60 Gy X-ray radiation dose on the hardness and dimensions of 3D-printed boluses. Four cuboids were printed on a Zortrax M200 printer with acrylonitrile–butadiene–styrene (ABS) polymer. All printed samples were exposed to 60 Gy of X-ray radiation delivered by a medical accelerator. After irradiation, changes in the hardness (using Vickers test) and dimensions of the prints were measured. The therapeutic X-ray dose had a minimal effect on the dimensions of the printed samples, resulting in a maximum contraction of only 0.4%. Changes of the hardness were not statistically significant. In conclusion, regarding the radiotherapy planning process, the application of this therapeutic X-ray dose does not significantly influence the hardness and dimensions of ABS-printed boluses.
1 September 2020 in Pomeranian Journal of Life Sciences
Introduction: This study aimed to determine whether the degradation of ascorbic acid in aqueous solutions could be used to compare the filtration efficiency of various household water filter jugs.Materials and methods: Based on absorbance measurements of ascorbic acid, a new water quality coefficient (WQC) parameter was defined. Differences between the WQC were determined for 4 different water filters commonly used in household water filter jugs in Poland. In addition, correlations between the WQC, the amount of filtered water (AFW), and a number of other parameters were examined for all 4 filters.Conclusions: Significant differences were found in WQC among the 4 filters. A decreasing efficiency of calcium ion removal from the water was observed with the ongoing use of all 4 filter cartridges. Overall, this method could be a sensitive, simple, fast, eco-friendly, and relatively inexpensive tool for determining the effectiveness of water purification in household water filter jugs, which of course requires further research.
Introduction: Radiotherapy plays a prominent role in the multidisciplinary treatment of cancers. Despite new irradiation techniques, radiation-induced cardiotoxicity remains a leading cause of morbidity and mortality. Therefore, prognostic indicators of radiotherapy toxicity are essential. This study aimed to investigate the influence of applied radiotherapy on the pulse wave recording and thereby on cardiovascular health, as well as to assess whether high signal resolution (HSR) pulse oximetry could be used as a prognostic indicator of radiotherapy toxicity. Methods: A total of 19 patients treated with radiotherapy to the lung or left breast were analyzed. Pulse oximetry was performed on all eligible patients (before and after the administration of a radiation dose) using the PULS-HSR program, which increases the resolution of the pulse wave recording. Results: Among the analyzed variables, we found the total dose administered to the target, as well as the treatment duration, significantly positively correlated with the change in ventricle/aorta volume ratio. The ventricle/aorta volume ratio parameter is the ratio between the area under the HSR pulse wave generated by the contraction of the left ventricle until the aortic valve closes and the area of the HSR pulse wave responsible for expansion and contraction of the aorta. Conclusion: The pilot study indicates HSR pulse oximetry, especially the ventricle/aorta volume ratio parameter, as a potential prognostic indicator of toxicity from radiation for breast and lung cancers.
We have developed a numerical model describing the optical and thermal behavior of optical tissue phantoms upon laser irradiation. According to our previous studies, the phantoms can be used as substitute of real skin from the optical, as well as thermal point of view. However, the thermal parameters are not entirely similar to those of real tissues thus there is a need to develop mathematical model, describing the thermal and optical response of such materials. This will facilitate the correction factors, which would be invaluable in translation between measurements on skin phantom to real tissues, and gave a good representation of a real case application. Here, we present the model dependent on the data of our optical phantoms fabricated and measured in our previous preliminary study. The ambiguity between the modeling and the thermal measurements depend on lack of accurate knowledge of material's thermal properties and some exact parameters of the laser beam. Those parameters were varied in the simulation, to provide an overview of possible parameters' ranges and the magnitude of thermal response.