Stanislaw Galla

Dr. Stanislaw Galla

Department of Metrology and Optoelectronics, Faculty of Electronics, Telecommunications and Informatics, Gdańsk University of Technology
orcid

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2015 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
MWMaciej Wrobel
Maciej Wrobel
Małgorzata SzczerskaMałgorzata Szczerska
Małgorzata Szczerska
SGStanislaw Galla
Stanislaw Galla
LPLeszek Piechowski
Leszek Piechowski
MSMiroslaw Sawczak
Miroslaw Sawczak
ACAdam Cenian
Adam Cenian
Skin lesions are commonly treated using laser heating. However, the introduction of new devices into clinical practice requires evaluation of their performance. This study presents the application of optical phantoms for assessment of a newly developed 975-nm pulsed diode laser system for dermatological purposes. Such phantoms closely mimic the absorption and scattering of real human skin (although not precisely in relation to thermal conductivity and capacitance); thus, they can be used as substitutes for human skin for approximate evaluation of laser heating efficiency in an almost real environment. Thermographic imaging was applied to measure the spatial and temporal temperature distributions on the surface of laser-irradiated phantoms. The study yielded results of heating with regard to phantom thickness and absorption, as well as laser settings. The methodology developed can be used in practice for preclinical evaluations of laser treatment for dermatology.

6 June 2018 in Energies
Verified
Journal Article
Open access
PDF file
MWMiroslaw Piotr Wlas
Miroslaw Piotr Wlas
SGStanislaw Galla
Stanislaw Galla
This article presents measurements of electric power absorbed by a newly built facility for office and scientific research activities. These measurements highlighted the need for compensation of capacitive reactive power—not predicted by the designer—due to the vast use of LED lighting in the facility. The article also describes a reactive power compensation system, designed on the basis of the above-mentioned measurements, and the introduced control and measurement system that enables on-site monitoring and online analysis of consumed energy and power. The research was carried out using popular LED lighting sources available on the local market (Poland). Basic electrical parameters of the locally available LEDs were measured as a function of the changes in harmonic levels occurring in the supply voltage. The test illustrated that samples were characterized by a very low power factor, which decreased as the level of harmonic disturbances increased. On the basis of the measurements, the authors suggest that obligatory requirements should be introduced in regard to the minimum power factor at the level of 0.9 for popular LED lighting sources (below 25 W).

5 June 2019 in Applied Sciences
Verified
Journal Article
Open access
PDF file
SGStanislaw Galla
Stanislaw Galla
ASArkadiusz Szewczyk
Arkadiusz Szewczyk
Janusz SmulkoJanusz Smulko
Janusz Smulko
PPPatryk Przygocki
Patryk Przygocki
This article presents the qualitative analyses of the construction of supercapacitor samples. The analyses are based on the suggested thermographic measurements as well as the technique of testing the inherent noise of the investigated element. The indicated assessment methods have been referred to the currently used parameters for the qualitative evaluation of supercapacitors. The approach described in this paper, which introduces additional parameters assessing worn out of supercapacitors, can be included in the so-called non-invasive measurement methods, which allow the assessment of the condition of the sample under test. This article presents the applied measurement stands and verifies of the applicability of measurement methods in relation to the currently used parameters allowing for the qualitative assessment of supercapacitors. The measurement method presented in this article was used to study prototypes of supercapacitors. The measurement results allow for more accurate characterization of the observed element. Conducted tests revealed, at the same time, that one of the proposed evaluation methods, based on measurements of inherent noise of tested supercapacitors, is a method predicting their degradation.

1 December 2017 in Applied Sciences
Verified
Journal Article
Open access
PDF file
SGStanislaw Galla
Stanislaw Galla
This paper describes a proposal for the qualitative assessment of condition of supercapacitors based on the conducted thermographic measurements. The presented measurement stand was accompanied by the concept of methodology of performing tests. Necessary conditions, which were needed to minimize the influence of disturbing factors on the performance of thermal imaging measurements, were also indicated. Mentioned factors resulted from both: the hardware limitations and from the necessity to prepare samples. The algorithm that was used to determine the basic parameters for assessment has been presented. The article suggests to use additional factors that may facilitate the analysis of obtained results. Measuring the usefulness of the proposed methodology was tested on commercial samples of supercapacitors. All of the tests were taken in conjunction with the classical methods based on capacitance (C) and equivalent series resistance (ESR) measurements, which were also presented in the paper. Selected results presenting the observed changes occurring in both: basic parameters of supercapacitors and accompanying fluctuations of thermal fields, along with analysis, were shown. The observed limitations of the proposed assessment method and the suggestions for its development were also described.

19 January 2022 in Energies
Verified
Journal Article
Open access
PDF file
MWMiroslaw Piotr Wlas
Miroslaw Piotr Wlas
SGStanislaw Galla
Stanislaw Galla
kouzou Abdellahkouzou Abdellah
kouzou Abdellah
PKPiotr Kołodziejek
Piotr Kołodziejek
This paper presents the analysis of an energy management system (EMS) implemented to fulfill the requirements of a microgrid (MG) power supply owned by a small industrial company and connected to the rural power system. The main goal of this system is to ensure connection with the existing rural power system in terms of energy exchange, as well as to perform islanding mode operation of the microgrid based on the energy demand of the company. Power generated in the implemented microgrid is based on a hybrid system supported by renewable energy sources and an energy storage system. The aim of the developed energy management system implemented in this MG power system is to enable the microgrid to operate according to scheduled diagrams related to different load events. The presented investigation, analysis, and assessment of the implemented energy management system are based on the on-site measurements and observations of the long-term operation of the microgrid concerning the hybrid renewable energy-based generation system and the company energy demand, which is useful from perspective of the predicted deficiency of electrical energy in Poland, both for customers and transmission system operators. Furthermore, the observed drawbacks and failures of the implemented EMS and the MG are pointed out and discussed to overcome and minimize these disadvantages, and to improve the operational reliability of the whole system.

21 April 2021 in Energies
Verified
Journal Article
Open access
PDF file
SGStanislaw Galla
Stanislaw Galla
MWMiroslaw Piotr Wlas
Miroslaw Piotr Wlas
This manuscript illustrates the measurement results of parameters describing the quality of energy at the PCC (point of common coupling) of a photovoltaic micro-installation that can significantly affect devices in the same power grid. The analyses reflecting heating of selected devices used in domestic installations, which were performed in an isolated laboratory environment, are also indicated. The conducted study aimed at checking the thermal characteristics of the chosen equipment, i.e., AC/DC power supply, LED and fluorescent light sources, a step-down transformer at synergistically higher voltage harmonics and constant component in the network voltage. The tests were carried out at the disturbance levels recorded at the site of the photovoltaic micro-installation. The conducted tests aimed at indicating the presence of an increased level of synergetic disturbances in the vicinity of micro-photovoltaic installations. Based on the research, recommendations were made for photovoltaic micro-installations.