Maciej Wrobel

Mr. Maciej Wrobel

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2015 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
MWMaciej Wrobel
Maciej Wrobel
Alexey PopovAlexey Popov
Alexey Popov
ABAlexander V. Bykov
Alexander V. Bykov
MKMatti Kinnunen
Matti Kinnunen
Małgorzata SzczerskaMałgorzata Szczerska
Małgorzata Szczerska
Valery TuchinValery Tuchin
Valery Tuchin
We present the optical measurement techniques used in human skin phantom studies. Their accuracy and the sources of errors in microscopic parameters’ estimation of the produced phantoms are described. We have produced optical phantoms for the purpose of simulating human skin tissue at the wavelength of 930 nm. Optical coherence tomography was used to measure the thickness and surface roughness and to detect the internal inhomogeneities. A more detailed study of phantom surface roughness was carried out with the optical profilometer. Reflectance, transmittance, and collimated transmittance of phantoms were measured using an integrating-sphere spectrometer setup. The scattering and absorption coefficients were calculated with the inverse adding-doubling method. The reduced scattering coefficient at 930 nm was found to be 1.57±0.14  mm−1 and the absorption was 0.22±0.03  mm−1. The retrieved optical properties of phantoms are in agreement with the data found in the literature for real human tissues.

4 May 2016 in Biomedical Optics Express
Verified
Journal Article
Open access
PDF file
MWMaciej Wrobel
Maciej Wrobel
Alexey PopovAlexey Popov
Alexey Popov
ABAlexander V. Bykov
Alexander V. Bykov
Valery TuchinValery Tuchin
Valery Tuchin
Małgorzata SzczerskaMałgorzata Szczerska
Małgorzata Szczerska
We present an alternative to the conventional approach, phantoms without scattering nanoparticles, where scattering is achieved by the material itself: spherical cavities trapped in a silicone matrix. We describe the properties and fabrication of novel optical phantoms based on a silicone elastomer polydimethylsiloxane (PDMS) and glycerol mixture. Optical properties (absorption coefficient µa, reduced scattering coefficient µs', and anisotropy factor g) of the fabricated phantoms were retrieved from spectrophotometric measurements (in the 400–1100 nm wavelength range) using the inverse adding-doubling method. The internal structure of the phantoms was studied under a scanning electron microscope, and the chemical composition was assessed by Raman spectroscopy. Composition of the phantom material is reported along with the full characterization of the produced phantoms and ways to control their parameters.

28 May 2015 in Journal of Innovative Optical Health Sciences
Verified
Journal Article
Open access
PDF file
MWMaciej Wrobel
Maciej Wrobel
Alexey PopovAlexey Popov
Alexey Popov
ABA. V. Bykov
A. V. Bykov
MKM. Kinnunen
M. Kinnunen
Małgorzata SzczerskaMałgorzata Szczerska
Małgorzata Szczerska
Valery TuchinValery Tuchin
Valery Tuchin
Extensive research in the area of optical sensing for medical diagnostics requires development of tissue phantoms with optical properties similar to those of living human tissues. Development and improvement of in vivo optical measurement systems requires the use of stable tissue phantoms with known characteristics, which are mainly used for calibration of such systems and testing their performance over time. Optical and mechanical properties of phantoms depend on their purpose. Nevertheless, they must accurately simulate specific tissues they are supposed to mimic. Many tissues and organs including head possess a multi-layered structure, with specific optical properties of each layer. However, such a structure is not always addressed in the present-day phantoms. In this paper, we focus on the development of a plain-parallel multi-layered phantom with optical properties (reduced scattering coefficient [ ] and absorption coefficient μ a ) corresponding to the human head layers, such as skin, skull, and gray and white matter of the brain tissue. The phantom is intended for use in noninvasive diffuse near-infrared spectroscopy (NIRS) of human brain. Optical parameters of the fabricated phantoms are reconstructed using spectrophotometry and inverse adding-doubling calculation method. The results show that polyvinyl chloride-plastisol (PVCP) and zinc oxide ( ZnO ) nanoparticles are suitable materials for fabrication of tissue mimicking phantoms with controlled scattering properties. Good matching was found between optical properties of phantoms and the corresponding values found in the literature.

1 January 2015 in Sensors and Actuators A: Physical
Verified
Journal Article
Closed access
Małgorzata SzczerskaMałgorzata Szczerska
Małgorzata Szczerska
PWPaweł Wierzba
Paweł Wierzba
ACA. Abou Chaaya
A. Abou Chaaya
Mikhael BECHELANYMikhael BECHELANY
Mikhael BECHELANY
PMPhilippe Miele
Philippe Miele
MWMaciej Wrobel
Maciej Wrobel

28 March 2017 in Materials
Verified
Journal Article
Open access
PDF file
MWMichał Wąsowicz
Michał Wąsowicz
Mateusz FicekMateusz Ficek
Mateusz Ficek
MWMaciej Wrobel
Maciej Wrobel
RCRuchira Chakraborty
Ruchira Chakraborty
Dror FixlerDror Fixler
Dror Fixler
Małgorzata SzczerskaMałgorzata Szczerska
Małgorzata Szczerska
This study reports the interactions of modified nanodiamond particles in vitro with human blood. Modifications performed on the nanodiamond particles include oxygenation with a chemical method and hydrogenation upon chemical vapor deposition (CVD) plasma treatment. Such nanodiamonds were later incubated in whole human blood for different time intervals, ranging from 5 min to 5 h. The morphology of red blood cells was assessed along with spectral measurements and determination of haemolysis. The results showed that no more than 3% of cells were affected by the nanodiamonds. Specific modifications of the nanodiamonds give us the possibility to obtain nanoparticles which are biocompatible with human blood. They can form a basis for the development of nanoscale biomarkers and parts of sensing systems and devices useful in biomedical environments.

14 March 2016 in Chemical Communications
Verified
Journal Article
Closed access
PDF file
SSSoumik Siddhanta
Soumik Siddhanta
MWMaciej Wrobel
Maciej Wrobel
IBIshan Barman
Ishan Barman
This report proposes a label-free, versatile approach for screening drugs of abuse using a combination of protein tethering and surface-enhanced Raman spectroscopy.