Peng Bao

Prof. Peng Bao

Henan University

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2022 in Journal of Renewable Materials
Verified
Journal Article
Open access
PDF file
SMShaochun Ma
Shaochun Ma
LWLin Wang
Lin Wang
PBPeng Bao
Peng Bao
There are a large number of historic buildings which were mainly made of blue-brick masonry in today’s world. However, for the natural and man-made reasons, these historic buildings have been damaged in different degrees. In order to protect historic buildings more scientifically and learn about the preservation state of existing historic buildings, it is necessary to ascertain the material properties of blue brick in historic buildings. The article takes the blue bricks of historical buildings in Kaifeng area of the Central Plains as an example to study. Through the analysis of physical properties, X-ray fluorescence spectroscopy, X-ray diffraction and scanning electron microscopy of blue brick specimens, the physical properties such as the apparent density, moisture content, porosity, and material structure composition are understood. The results show that the apparent density of blue brick is 1.64 g/cm3 , the moisture content is 10.23%, the 24 h atmospheric water absorption is 17.86%, and the porosity is 20.99%. The smaller the apparent density is, the larger the porosity is, and the water absorption performance is better. From the microscopic point of view, bonding ability between blue brick mineral particles is relatively weak. The pores between skeletons are large and the pore structure is obvious. From the perspective of material phase, the elements of blue brick are mainly O, Si, Al, Fe, and the composition of blue brick is mainly composed of quartz and feldspar. The softening coefficient of blue brick is 0.80, and the deformation and stability of the structure should be paid special attention in the rainy season or wet environment. Through the frost test, there are salt substances in the internal pores of the brick, and the surface of the blue brick is eroded and pulverized. In this paper, the experimental process and analysis methods for testing the material properties of blue brick can provide reference for the research on the material properties of the same kind of blue-brick masonry in historic buildings and masonry relics. The relevant material property parameters obtained in this paper can provide guidance for making protection schemes and scientific repairs for historic buildings in Central China, enrich the evaluation criteria for maintaining and reinforcing historic buildings, and provide theoretical support for studying the damage and health detection technology related to historic buildings.

19 October 2021 in Scientific Reports
Verified
Journal Article
Open access
PDF file
SMShaochun Ma
Shaochun Ma
YWYouwen Wu
Youwen Wu
PBPeng Bao
Peng Bao
This article presents building assessment research comprising on-site inspections, indoor scientific tests, and material performance studies on the wall blue clay bricks in the Kaifeng People’s Conference Hall, objectively developing an enhanced scientific understanding to renovate modern buildings. Using X-ray diffraction (XRD), scanning electron microscopy (SEM), alongside a parametric study of density, moisture content, water absorption, void ratio, frosting, compressive strength, and softening coefficient in assessing the material health of the blue clay bricks and it’s non-key parts, in developing “appropriate and compatible renovation” to repair contemporaneous buildings. The composition, pore characteristics, weathering degree, and mechanical properties of the blue clay brick samples were analyzed. These parameters showed that blue clay brick fired at less than 1000 °C; the main mineral composition as quartz, followed by albite, mica, and anorthite. Its density was 1.573 g/cm3, less than the 1.70 g/cm3of ordinary clay brick. According to the standards, the water absorption was greater than that of regular sintered bricks by more than 18% and was slightly frosted. Compressive strength being less than MU10 did not meet the current design specifications for masonry. Its softening coefficient was between 0.70 and 0.85, but its water resistance was relatively good. The research results provide an essential reference for judging the health and longevity of modern buildings to achieve scientific guidelines for practical protection.

17 March 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
SMShaochun Ma
Shaochun Ma
LLLianghui Li
Lianghui Li
PBPeng Bao
Peng Bao
The research objective of this study was the seismic performance of double-row reinforced ceramsite concrete sandwich wall panels. The feasibility of upgrading a new wall panel from a non-load-bearing partition wall to a load-bearing seismic wall was examined by conducting cyclic load tests on five wall panel specimens. The test piece was a sandwich thermal insulation structure that could achieve a good protection distance between the thermal insulation material and the fire source so that the fire prevention problem could be solved. At the same time, the problem of easy fall-off of the insulation system was also solved. The specimens were divided into three groups, including three double-row reinforced ceramsite concrete sandwich wall panels with different dosages of alkali-resistant glass fiber, a double-row reinforced ordinary concrete sandwich wall panel, and a solid concrete ceramic wallboard. The effects of different dosages of alkali-resistant glass fiber, construction forms, and bearing side plate materials on the seismic performance of the sandwich wall panels were investigated separately for the specimens. From the analysis of the specimen results (damage characteristics, hysteresis curves, energy dissipation capacity, bearing capacity, ductility, longitudinal reinforcement strain, and stiffness degradation), it could be seen that among the five types of wallboard, the double-row reinforced ceramsite concrete sandwich wall panel with 0.3% fiber content had the best ductility and energy dissipation capacity. Adding fiber could solve or improve the problem of the low ultimate bearing capacity of ceramsite concrete as the wallboard’s bearing material. Compared with the same size solid ordinary concrete wallboard, the bearing capacity of the double-row reinforced ceramic concrete sandwich panel was slightly reduced. However, the additional seismic performance indexes were relatively superior. Through the analysis of the test results, it was shown that, when considering the thermal performance and seismic capacity, the new wall panel had good prospects for engineering applications.

18 April 2022 in Arabian Journal for Science and Engineering
Verified
Journal Article
Closed access
PDF file
SMShaochun Ma
Shaochun Ma
YWYouwen Wu
Youwen Wu
PBPeng Bao
Peng Bao

20 July 2022 in International Journal of Civil Engineering
Verified
Journal Article
Closed access
PDF file
SMShaochun Ma
Shaochun Ma
LCLong Chen
Long Chen
PBPeng Bao
Peng Bao
DWDongtao Wang
Dongtao Wang

13 December 2022 in Buildings
Verified
Journal Article
Open access
PDF file
LLLianghui Li
Lianghui Li
SMShaochun Ma
Shaochun Ma
PBPeng Bao
Peng Bao
HWHao Wang
Hao Wang
Ceramsite concrete, with its advantages such as excellent long-term durability and thermal insulation properties, is suitable to be utilized as precast sandwich wall panels. While the lack of assessment of the seismic performance of such wall panel joints has been studied. Therefore, an experimental program was carried out to investigate and improve the seismic performance of the new type of wall panel joints. The seismic performances of the specimens were experimentally evaluated, including failure mode, loading and deformation capacity, ductility, the strain of vertically distributed steels, stiffness, and energy dissipation. The insulated sandwich wall panel joints have good seismic performance shown by the quasi-static test. The ductility coefficient of all specimens was greater than 3. The structure of the control group specimen presented a better match in stiffness, bearing capacity, ductility, and energy dissipation. The sleeve connection confirmed that the integrity of the joint, and the L-shaped hidden column could improve the ductility coefficient and equivalent viscous damping coefficient by about 4.2%. The results can promote the research of such wallboard system. This design approach of sandwich wall panel joints with lightweight concrete is broadly applicable to the exploration of more types of energy-saving wallboard systems.