Baiqian Shi

Mr. Baiqian Shi

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2019 in Journal of Environmental Management
Verified
Journal Article
Closed access
BSBaiqian Shi
Baiqian Shi
Peter M. BachPeter M. Bach
Peter M. Bach
ALAnna Lintern
Anna Lintern
KZKefeng Zhang
Kefeng Zhang
RCRhys A. Coleman
Rhys A. Coleman
ADAna Deletic
Ana Deletic

27 April 2021 in Sensors
Verified
Journal Article
Open access
PDF file
BSBaiqian Shi
Baiqian Shi
SCStephen Catsamas
Stephen Catsamas
PKPeter Kolotelo
Peter Kolotelo
MWMIAO WANG
MIAO WANG
ALAnna Lintern
Anna Lintern
David McCarthyDavid McCarthy
David McCarthy
High-resolution data collection of the urban stormwater network is crucial for future asset management and illicit discharge detection, but often too expensive as sensors and ongoing frequent maintenance works are not affordable. We developed an integrated water depth, electrical conductivity (EC), and temperature sensor that is inexpensive (USD 25), low power, and easily implemented in urban drainage networks. Our low-cost sensor reliably measures the rate-of-change of water level without any re-calibration by comparing with industry-standard instruments such as HACH and HORIBA’s probes. To overcome the observed drift of level sensors, we developed an automated re-calibration approach, which significantly improved its accuracy. For applications like monitoring stormwater drains, such an approach will make higher-resolution sensing feasible from the budget control considerations, since the regular sensor re-calibration will no longer be required. For other applications like monitoring wetlands or wastewater networks, a manual re-calibration every two weeks is required to limit the sensor’s inaccuracies to ±10 mm. Apart from only being used as a calibrator for the level sensor, the conductivity sensor in this study adequately monitored EC between 0 and 10 mS/cm with a 17% relative uncertainty, which is sufficient for stormwater monitoring, especially for real-time detection of poor stormwater quality inputs. Overall, our proposed sensor can be rapidly and densely deployed in the urban drainage network for revolutionised high-density monitoring that cannot be achieved before with high-end loggers and sensors.

29 March 2025 in Journal of Environmental Chemical Engineering
Verified
Journal Article
Open access
MJMehran Janmohammadi
Mehran Janmohammadi
BSBaiqian Shi
Baiqian Shi
TATanveer M. Adyel
Tanveer M. Adyel
DMDavid McCarthy
David McCarthy

1 December 2019
Verified
Conference Paper
Open access
DGDanlu GUO
Danlu GUO
ALAnna Lintern
Anna Lintern
VPV Prodanov
V Prodanov
MKMichael Kull
Michael Kull
ADA Delet
A Delet
AWAndrew W. Western
Andrew W. Western