MIAO WANG

Mr. MIAO WANG

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 April 2021 in Sensors
Verified
Journal Article
Open access
PDF file
BSBaiqian Shi
Baiqian Shi
SCStephen Catsamas
Stephen Catsamas
PKPeter Kolotelo
Peter Kolotelo
MWMIAO WANG
MIAO WANG
ALAnna Lintern
Anna Lintern
David McCarthyDavid McCarthy
David McCarthy
High-resolution data collection of the urban stormwater network is crucial for future asset management and illicit discharge detection, but often too expensive as sensors and ongoing frequent maintenance works are not affordable. We developed an integrated water depth, electrical conductivity (EC), and temperature sensor that is inexpensive (USD 25), low power, and easily implemented in urban drainage networks. Our low-cost sensor reliably measures the rate-of-change of water level without any re-calibration by comparing with industry-standard instruments such as HACH and HORIBA’s probes. To overcome the observed drift of level sensors, we developed an automated re-calibration approach, which significantly improved its accuracy. For applications like monitoring stormwater drains, such an approach will make higher-resolution sensing feasible from the budget control considerations, since the regular sensor re-calibration will no longer be required. For other applications like monitoring wetlands or wastewater networks, a manual re-calibration every two weeks is required to limit the sensor’s inaccuracies to ±10 mm. Apart from only being used as a calibrator for the level sensor, the conductivity sensor in this study adequately monitored EC between 0 and 10 mS/cm with a 17% relative uncertainty, which is sufficient for stormwater monitoring, especially for real-time detection of poor stormwater quality inputs. Overall, our proposed sensor can be rapidly and densely deployed in the urban drainage network for revolutionised high-density monitoring that cannot be achieved before with high-end loggers and sensors.

11 July 2023 in Sensors
Verified
Journal Article
Open access
PDF file
SCStephen Catsamas
Stephen Catsamas
BSBaiqian Shi
Baiqian Shi
MWMIAO WANG
MIAO WANG
JXJieren Xiao
Jieren Xiao
PKPeter Kolotelo
Peter Kolotelo
David McCarthyDavid McCarthy
David McCarthy
We designed an out-of-water radar water velocity and depth sensor, which is unique due to its low cost and low power consumption. The sensor is a first at a cost of less than USD 50, which is well suited to previously cost-prohibited high-resolution monitoring schemes. This use case is further supported by its out-of-water operation, which provides low-effort installations and longer maintenance-free intervals when compared with in-water sensors. The inclusion of both velocity and depth measurement capabilities allows the sensor to also be used as an all-in-one solution for flowrate measurement. We discuss the design of the sensor, which has been made freely available under open-hardware and open-source licenses. The design uses commonly available electronic components, and a 3D-printed casing makes the design easy to replicate and modify. Not before seen on a hydrology sensor, we include a 3D-printed radar lens in the casing, which boosts radar sensitivity by 21 dB. The velocity and depth-sensing performance were characterised in laboratory and in-field tests. The depth is accurate to within ±6% and ±7 mm and the uncertainty in the velocity measurements ranges from less than 30% to 36% in both laboratory and field conditions. Our sensor is demonstrated to be a feasible low-cost design which nears the uncertainty of current, yet more expensive, velocity sensors, especially when field performance is considered.

17 June 2024 in Sensors
Verified
Journal Article
Open access
PDF file
MWMIAO WANG
MIAO WANG
BSBaiqian Shi
Baiqian Shi
SCStephen Catsamas
Stephen Catsamas
PKPeter Kolotelo
Peter Kolotelo
DMDavid McCarthy
David McCarthy
Turbidity stands as a crucial indicator for assessing water quality, and while turbidity sensors exist, their high cost prohibits their extensive use. In this paper, we introduce an innovative turbidity sensor, and it is the first low-cost turbidity sensor that is designed specifically for long-term stormwater in-field monitoring. Its low cost (USD 23.50) enables the implementation of high spatial resolution monitoring schemes. The sensor design is available under open hardware and open-source licences, and the 3D-printed sensor housing is free to modify based on different monitoring purposes and ambient conditions. The sensor was tested both in the laboratory and in the field. By testing the sensor in the lab with standard turbidity solutions, the proposed low-cost turbidity sensor demonstrated a strong linear correlation between a low-cost sensor and a commercial hand-held turbidimeter. In the field, the low-cost sensor measurements were statistically significantly correlated to a standard high-cost commercial turbidity sensor. Biofouling and drifting issues were also analysed after the sensors were deployed in the field for more than 6 months, showing that both biofouling and drift occur during monitoring. Nonetheless, in terms of maintenance requirements, the low-cost sensor exhibited similar needs compared to the GreenSpan sensor.

30 September 2022 in Sensors
Verified
Journal Article
Open access
PDF file
SCStephen Catsamas
Stephen Catsamas
BSBaiqian Shi
Baiqian Shi
BDBoris Deletic
Boris Deletic
MWMIAO WANG
MIAO WANG
David McCarthyDavid McCarthy
David McCarthy
Current commercial sensors to monitor water flow velocities are expensive, bulky, and require significant effort to install. Low-cost sensors open the possibility of monitoring storm and waste water systems at a much greater spatial and temporal resolution without prohibitive costs and resource investment. To aid in this, this work developed a low-cost, low-power velocity sensor based on acoustic Doppler velocimetry. The sensor, costing less than 50 USD is open-source, open-hardware, compact, and easily interfaceable to a wide range of data-logging systems. A freely available sensor design at this price point does not currently exist, and its novelty is in enabling high-resolution real-time monitoring schemes. The design is capable of measuring water velocities up to 1200 mm/s. The sensor is characterised and then verified in an in-field long-term test. Finally, the data from this test are then used to evaluate the performance of the sensor in a real-world scenario. The analysis concludes that the sensor is capable of effectively measuring water velocity.

23 April 2024 in Preprints.org
Verified
Preprint
Open access
PDF file
MWMIAO WANG
MIAO WANG
BSBaiqian Shi
Baiqian Shi
SCStephen Catsamas
Stephen Catsamas
PKPeter Kolotelo
Peter Kolotelo
DMDavid McCarthy
David McCarthy
Turbidity stands as a crucial indicator for assessing water quality, and while turbidity sensors exist their high cost prohibit their extensive use. In this paper, we introduce an innovative turbidity sensor, and it is the first low-cost turbidity sensor which is designed specifically for long-term stormwater in-field monitoring. Its low cost ($23.50 USD), enables the implementation of high spatial resolution monitoring schemes. The sensor design is available under open hardware and open-source licences, and the 3D-printed sensor housing is free to modify based on different monitoring purposes and ambient conditions. The sensor was tested both in the laboratory and in the field. The laboratory results show a strong linear relationship (R2 > 0.99) between the sensor readings and the commercial hand-held turbidimeter (Thermo Scientific AQ4500) results of the solution. In the field, the low-cost sensor measurements were statistically significantly correlated (p < 0.01) to a standard high-cost commercial turbidity sensor (GreenSpan TS-1000). Biofouling and drifting issues were also analysed after the sensors were deployed in the field for more than 6 months, showing both biofouling and drift occur during monitoring. Nonetheless, in terms of maintenance requirements, the low-cost sensor exhibited similar needs compared to the Green-Span sensor.

2 April 2026 in Structure and Infrastructure Engineering
Verified
Journal Article
Open access
SPSpyros Pritsis
Spyros Pritsis
Francois ClemensFrancois Clemens
Francois Clemens
SKSebastian Kerger
Sebastian Kerger
ALAbigail Legge
Abigail Legge
MWMIAO WANG
MIAO WANG
FTFranz Tscheikner-Gratl
Franz Tscheikner-Gratl
1. The selection of monitoring sites in urban drainage networks (UDNs) is a critical aspect of effective network management and modelling. Over the past decades, various studies have attempted to a...