Tae-Youl Choi

Prof. Tae-Youl Choi


Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 July 2009 in Nanotechnology
Verified
Journal Article
Closed access
TCTae-Youl Choi
Tae-Youl Choi
MMMohammad H Maneshian
Mohammad H Maneshian
BKBoseon Kang
Boseon Kang
WCWon S Chang
Won S Chang
CHChang S Han
Chang S Han
DPDimos Poulikakos
Dimos Poulikakos
A modified 3-omega method applied to a suspended platinum microwire was employed to measure the thermal conductivity and convective heat transfer coefficient of a water-based single-walled carbon nanotube (CNT) solution (metallic single-wall nanotubes with 1.33 nm diameter and 1.14 wt% concentration), and an expression for calculating the convective heat transfer coefficient in such a free convective fluid was introduced. The measurement technique was validated for three model systems including vacuum, air and deionized water. It is found that there is excellent agreement between these three model systems with theoretical predictions. In addition, the frequency dependence on the third harmonic response measured in deionized water reveals the existence of a very low working frequency below 60 mHz. The thermal conductivity and convective heat transfer coefficient of the nanofluid (water-based single-wall CNT solution) were determined to be 0.73 +/- 0.013 W m(-1) K(-1) and 14 900 +/- 260 W m(-2) K(-1), respectively, which correspond to an enhancement of 19.4% in thermal conductivity and 18.9% in convective heat transfer as compared to water.

13 September 2011 in Sensors
Verified
Journal Article
Open access
PDF file
RSRamesh Shrestha
Ramesh Shrestha
TCTae-Youl Choi
Tae-Youl Choi
WCWon Seok Chang
Won Seok Chang
Dongsik KimDongsik Kim
Dongsik Kim
We report herein development of a novel glass micropipette thermal sensor fabricated in a cost-effective manner, which is capable of measuring steady thermal fluctuation at spatial resolution of ~2 µm with an accuracy of ±0.01 °C. We produced and tested various micrometer-sized sensors, ranging from 2 µm to 30 µm. The sensor comprises unleaded low-melting-point solder alloy (Sn-based) as a core metal inside a pulled borosilicate glass pipette and a thin film of nickel coating outside, creating a thermocouple junction at the tip. The sensor was calibrated using a thermally insulated calibration chamber, the temperature of which can be controlled with an accuracy of ±0.01 °C, and the thermoelectric power (Seebeck coefficient) of the sensor was recorded from 8.46 to 8.86 µV/°C. We have demonstrated the capability of measuring temperatures at a cellular level by inserting our temperature sensor into the membrane of a live retinal pigment epithelium cell subjected to a laser beam with a focal spot of 6 μm. We measured transient temperature profiles and the maximum temperatures were in the range of 38–55 ± 0.5 °C.

22 December 2011 in Applied Physics A
Verified
Journal Article
Closed access
PDF file
KLKyung-Min Lee
Kyung-Min Lee
SLSang-Kwon Lee
Sang-Kwon Lee
TCTae-Youl Choi
Tae-Youl Choi

1 March 2013 in Review of Scientific Instruments
Verified
Journal Article
Closed access
RSR. Shrestha
R. Shrestha
KLK. M. Lee
K. M. Lee
WCW. S. Chang
W. S. Chang
DKD. S. Kim
D. S. Kim
GRG. H. Rhee
G. H. Rhee
TCTae-Youl Choi
Tae-Youl Choi
In this paper, we describe the thermal conductivity measurement of single-walled carbon nanotubes thin film using a laser point source-based steady state heat conduction method. A high precision micropipette thermal sensor fabricated with a sensing tip size varying from 2 μm to 5 μm and capable of measuring thermal fluctuation with resolution of ±0.01 K was used to measure the temperature gradient across the suspended carbon nanotubes (CNT) film with a thickness of 100 nm. We used a steady heat conduction model to correlate the temperature gradient to the thermal conductivity of the film. We measured the average thermal conductivity of CNT film as 74.3 ± 7.9 W m−1 K−1 at room temperature.

1 January 2008
Verified
Conference Paper
Closed access
PDF file
TCTae-Youl Choi
Tae-Youl Choi
DPDimos Poulikakos
Dimos Poulikakos
Focused-ion-beam (FIB) is a useful tool for defining nanoscale structures. High energy heavy ions inherently exhibit destructive nature. A less destructive tool has been devised by using electron beam. FIB is mainly considered as an etching tool, while electron beam can be used for deposition purpose. In this paper, both etching and deposition method are demonstrated for applications in thermal science. Thermal conductivity of nanostructures (such as carbon nanotubes) was measured by using the FIB (and electron beam) nanolithography technique. Boiling characteristics was studied in a submicron heater that could be fabricated by using FIB.

6 December 2013
Verified
Book Chapter
Closed access
PDF file
KLKyung-Min Lee
Kyung-Min Lee
TCTae-Youl Choi
Tae-Youl Choi