This study presents an efficient hybrid mechanical and power electronic (MPE) DC circuit breaker (DCCB) to solve the challenges of conventional hybrid MPE DCCBs. The main branch of the proposed topology reduces on-state losses to a negligible magnitude by utilizing only mechanical switches such as the residual current switch (RCS), fast mechanical switch (FMS), and monostable mechanical switch (MMS). Additionally, it significantly decreases the number of semiconductor devices by employing a series connection between the FMS and the main current breaker (MCB). The DC interruption capability of the proposed hybrid MPE DCCB topology was verified through a simulation based on equivalent electric circuits, and the DC interruption capability of the proposed medium-voltage (MV) class hybrid MPE DCCB was evaluated using a DC interruption test.
This paper presents a structural optimization technique based on precise heat transfer analysis for transformers. Mechanical and thermal stresses during operation are particularly critical in confined environments, such as within wind turbine generators. To optimize the transformer’s structure, the temperature distribution is first calculated using computational fluid dynamics (CFD) based on the finite volume method. Eddy current losses, necessary for thermal analysis, are determined through electromagnetic analysis. These CFD results are then used as input conditions for structural analysis. Finally, structural optimization is performed on critical areas, primarily the radiation fins and panels. All models are analyzed in 3D, and the simulation results are validated through comparison with experimental data. Consequently, the optimized design results were validated against simulations, exhibiting a maximum deviation of 4%. These findings confirm the success of the proposed transformer design optimization.
23 March 2024 in Journal of Electrical Engineering & Technology
The increasing concerns surrounding global warming and its adverse effects have contributed to the rising demand for SF 6 -free eco-friendly gas circuit breakers (GCBs). In particular, CO 2 /O 2 mixtures possess better arc-quenching capabilities than pure CO 2 , making them suitable insulation gases for eco-friendly GCBs. This study proposes a multiphysics model combining electric, fluid dynamics, and radiation models to evaluate the thermal interruption capability in a 72.5-kV GCB using a CO 2 /O 2 mixture gas. The pressure rise inside the thermal chamber and arc voltage of a prototype gas interrupter adopting a CO 2 /O 2 mixture gas were calculated using the proposed model. The feasibility of the model was verified through a comparison of the calculated pressure rise and arc voltage with the measurement results. Further, we calculated the temperature, pressure, and PTFE ablation distribution of the 72.5 kV GCB with the CO 2 /O 2 mixture gas. Based on these results, we estimated the thermal interruption capabilities, specifically, the post-arc current (PAC) and G 200 indices. The numerical investigation of the thermal interruption capability can contribute to the design of GCB interrupters using CO 2 /O 2 mixture gas.
2 October 2025 in IEEE Transactions on Industrial Electronics
In this article, a new bidirectional dc circuit breaker (DCCB) topology based on Z-source principles is presented. The new DCCB topology is featured with the reprotection capability and safely protects the dc source and load even when a utility controller tries to reengage the DCCB with an uncleared fault. Our topology is efficient as it only includes one semiconductor device in its current path during normal operation and is symmetrically built to provide bidirectionality. With an additional current path for a fault, our new DCCB suppresses the reflection of the fault current onto the source side, enhancing equipment protection. Detailed mathematical models are built in this article to analyze the protection mechanism, operation performance, and short-circuit fault responses. This article also discusses how to expedite the fault-clearing and reclosing processes. In addition, this article explores the impact of the reverse recovery of semiconductor devices in DCCBs and provides a mitigation strategy. A laboratory-scale prototype is built to validate the theoretical analyses and verify the benefits of the proposed bidirectional dc circuit breaker topology.