The present study considers evaporative cooling and desiccant unit-based air-conditioning (AC) options for livestock AC application. In this regard, proposed systems are investigated by means of experiments and thermodynamic investigations. Air-conditioning requirements for animals are theoretically investigated and temperature-humidity index (THI) is estimated. A lab-scale heat mass exchanger based on the Maisotsenko-cycle evaporative cooling conception (MEC) is set up and its performance is evaluated at different ambient air conditions. In addition, a desiccant-based air-conditioning (DAC) unit is thermodynamically evaluated using a steady-state model available in the literature. The study focuses on the ambient conditions of Multan which is the 5th largest city of Pakistan and is assumed to be a typical hot city of southern Punjab. The study proposed three kinds of AC combination i.e., (i) stand-alone MEC, (ii) stand-alone desiccant AC, and (iii) M-cycle based desiccant AC systems. Wet bulb effectiveness of the stand-alone MEC unit resulted in being from 64% to 78% whereas the coefficient of performance for stand-alone desiccant AC and M-cycle based desiccant AC system was found to be 0.51 and 0.62, respectively. Results showed that the stand-alone MEC and M-cycle based desiccant AC systems can achieve the animals’ thermal comfort for the months of March to June and March to September, respectively, whereas, stand-alone desiccant AC is not found to be feasible in any month. In addition, the ambient situations of winter months (October to February) are already within the range of animal thermal comfort.
The exergy, entropy, and entransy analysis for a dual-loop organic Rankine cycle (DORC) using a mixture of working fluids have been investigated in this study. A high-temperature (HT) loop was used to recover waste heat from internal combustion engine in 350 °C, and a low-temperature loop (LT) was used to absorb residual heat of engine exhaust gas and HT loop working fluids. Hexane/toluene, cyclopentane/toluene, and R123/toluene were selected as working fluid mixtures for HT loop, while R245fa/pentane was chosen for LT loop. Results indicated that the variation of entropy generation rate, entransy loss, entransy efficiency, and exergy loss are insensitive to the working fluids. The entransy loss rate and system net power output present the same variation trends, whereas a reverse trend for entropy generation rate and entransy efficiency, while the exergy analysis proved to be only utilized under fixed stream conditions. The results also showed that hexane/toluene is the preferred mixture fluid for DORC.
Cogeneration of heat and power systems based on the organic Rankine cycle (ORC-CHP) has been proven to be an effective way to utilize waste heat at medium and low temperatures. In this work, three ORC-CHP (combined heat and power based on organic Rankine cycle) systems are simulated and compared, including the SS (serial system), the CS (the condensation system), and the SS/CS. The multi-objective genetic algorithm (MOGA) is used to optimize the three systems respectively to achieve higher exergy efficiency and profit ratio of investment (PRI). The optimal thermal-economic performance is obtained. Twelve organic fluids are adopted to evaluate their performance as working fluids. The calculation results show that SS has the highest exergy efficiency, while SS/CS has the best economic performance. Compared with the highest exergy efficiency of SS and the best economic performance of SS/CS, CS will be the optimal solution considering these two objective functions. Under the optimal working conditions, SS has the highest thermal efficiency because it has the highest net power output. The components with the largest proportion of exergy destruction are the heat exchangers, which also has the highest cost.
In this study, the ideal adsorption cycle behavior of eight activated carbon and refrigerant pairs is evaluated. The selected pairs are KOH6-PR/ethanol, WPT-AC/ethanol, Maxsorb-III/methanol, Maxsorb-III/CO2, Maxsorb-III/n-butane, Maxsorb-III/R-134a, SAC-2/R32 and Maxsorb-III/R507a. The following cooling performance parameters are evaluated for all pairs: specific cooling energy (SCE), concentration difference (ΔW) and coefficient of performance (COP) of ideal adsorption cooling and refrigeration cycles. The evaporator temperatures for the applications of adsorption cooling and refrigeration are selected as 7 and −5 °C, respectively. It is found that the Maxsorb-III/methanol pair has shown the highest specific cooling energy and coefficient of performance in a wide range of desorption temperatures; i.e., for the adsorption cooling cycle it has SCE and COP of 639.83 kJ/kg and 0.803, respectively, with desorption temperatures of 80 °C. The KOH6-PR/ethanol and the WPT-AC/ethanol pairs also give good performances comparable to that of the Maxsorb-III/methanol pair. However, the SAC-2/R32 pair possesses a higher concentration difference than the Maxsorb-III/methanol, KOH6-PR/ethanol and WPT-AC/ethanol pairs but shows a lower performance. This is due to the lower isosteric heat of adsorption of SAC-2/R32 compared to these pairs. It is found that Maxsorb-III/methanol, KOH6-PR/ethanol and WPT-AC/ethanol are the most promising pairs for application in designing adsorption cooling and refrigeration systems.
Nuclear energy, as an important component of the power system, has become a key focus of future energy development research. Various equipment and pipelines in nuclear power plants require regular inspection, maintenance, and repair. The pipelines in nuclear power plants are typically large, necessitating a device that can locally isolate sections of the pipeline during maintenance operations. Ice plug freezing technology, an economical and efficient method for maintaining and replacing equipment without shutdown, has been widely applied in nuclear power plants. The structure of the ice plug jacket, a type of low-temperature jacket heat exchanger, affects the flow path of the working fluid within the jacket and consequently impacts heat transfer. This study utilizes Computational Fluid Dynamics (CFD) to establish five types of jacket structures: standard, center-offset (center-in, side-out), helical, helical fin, and labyrinth. The effects of different structures on the freezing characteristics of ice plugs are analyzed and compared. The research indicates that the labyrinth jacket enhances the heat transfer performance between liquid nitrogen and the liquid inside the pipe, forming a larger ice layer at the same liquid nitrogen flow rate. Additionally, the standard jacket has the shortest sealing time at high liquid nitrogen flow rates.
Ice plug technology is an effective method for isolating the pipeline system, which are promising methods utilized in the nuclear, chemical, and power industries. To reduce the cold energy consumption and temperature stress, the multi-stage (1–10) of time-dependent thermal boundary conditions was proposed for the formation of ice plug, while the gradient cooling wall temperature of multi-stage was applied. A numerical model considering the liquid–solid phase change, heat transfer, and time-dependent thermal boundary condition has been established. The effects of the ratio of length and diameter of the cooling wall lc/d (1–9) on the formation rate and heat flux of ice plug in the pipe has been investigated. The fastest formation rate of ice plug with 800 mm in the axial direction (7.47 cm3/s) was observed in the pipe with the lc/d of 5. The formation rate of ice plug and the ice formation volume under unit energy consumption VE under various stages (1–10) of cooling wall temperature have been compared. The VE of eight temperature stages (1.45 cm3/kJ) was 1.16 times than the VE of one temperature stage, which satisfied the freezing rate at the same time. This investigation provides insight for proposing an energy-saving system for the formation of ice plug.