Biosensors represent an attractive approach for fast bacteria detection. Here, we present an optical biosensor for the detection of Salmonella typhimurium lipopolysaccharide (LPS) and Salmonella bacteria in drinking water, based on white light reflectance spectroscopy. The sensor chip consisted of a Si die with a thin SiO2 layer on top that was transformed into a biosensor through the immobilization of Salmonella LPS. The optical setup included a reflection probe with seven 200 μm fibers, a visible and near-infrared light source, and a spectrometer. The six fibers at the reflection probe circumference were coupled with the light source and illuminated the biosensor chip vertically, whereas the central fiber collected the reflected light and guided it to the spectrometer. A competitive immunoassay configuration was adopted for the analysis. Accordingly, a mixture of LPS or bacteria solution, pre-incubated for 15 min, with an anti-Salmonella LPS antibody was pumped over the chip followed by biotinylated secondary antibody and streptavidin for signal enhancement. The binding of the free anti-Salmonella antibody to chip-immobilized LPS led to a shift of the reflectance spectrum that was inversely related to the analyte concentration (LPS or bacteria) in the calibrators or samples. The total assay duration was 15 min, and the detection limits achieved were 4 ng/mL for LPS and 320 CFU/mL for bacteria. Taking into account the low detection limits, the short analysis time, and the small size of the chip and instrumentation employed, the proposed immunosensor could find wide application for bacteria detection in drinking water.
Optical immunosensors represent a research field of continuously increasing interest due to their unique features, which can mainly be attributed to the high-affinity and specific antibodies they use as biorecognition elements, combined with the advantageous characteristics of the optical transducing systems these sensors employ. The present work describes new developments in the field, focusing on recent bioanalytical applications (2021–2022) of labeled and label-free optical immunosensors. Special attention is paid to a specific immunosensing platform based on White Light Reflectance Spectroscopy, in which our labs have gained specific expertise; this platform is presented in detail so as to include developments, improvements, and bioanalytical applications since the mid-2000s. Perspectives on the field are been briefly discussed as well, highlighting the potential of optical immunosensors to eventually reach the state of a reliable, highly versatile, and widely applicable analytical tool suitable for use at the Point-of-Care.
In this work, we consider White Light Reflectance Spectroscopy (WLRS) as an optical methodology for the accurate, fast and non-destructive measurement of film thickness in the 1 nm to the 1 mm range and for applications that include microelectronics, photonics, bioanalysis and packaging. Films to which WLRS is applicable can be either homogeneous or layered-composite ones, while thickness and composition might be fixed or varying with time; in the latter case, real-time monitoring of the kinetics of processes such as certain transitions, film dissolution and bioreactions is possible. We present the basic principles of WLRS and a selection of characteristic application examples of current interest, and we also briefly compare WLRS with alternative methods for film measurement.
Ochratoxin A (OTA) is one of the most toxic naturally encountered contaminants and is found in a variety of foods and beverages, including cereals and wine. Driven by the strict regulations regarding the maximum allowable OTA concentration in foodstuff and the necessity for on-site determination, the development of fast and sensitive methods for the OTA determination in cereal flours and wine samples, based on white light reflectance spectroscopy, is presented. The method relied on appropriately engineered silicon chips, on top of which an OTA-protein conjugate was immobilized. A polyclonal antibody against OTA was then employed to detect the analyte in the framework of a competitive immunoassay; followed by the subsequent addition of a biotinylated secondary antibody and streptavidin for signal enhancement. A small size instrument performed all assay steps automatically and the bioreactions were monitored in real time as the software converted the spectral shifts into effective biomolecular adlayer thickness increase. The assay developed had a detection limit of 0.03 ng/mL and a working range up to 200 ng/mL. The assay lasted 25 min (less than 1h, including calibrators/antibody pre-incubation) and was accomplished following a simple sample preparation protocol. The method was applied to corn and wheat flour samples and white and red wines with recovery values ranging from 87.2 to 111%. The simplicity of the overall assay protocol and convenient instrumentation demonstrates the potential of the immunosensor developed for OTA detection at the point of need.
Spectroscopic reflectance is a versatile optical methodology for the characterization of transparent and semi-transparent thin films in terms of thickness and refractive index. The Fresnel equations are used to interpret the measurements, but their accuracy is limited when surface roughness is present. Nanoroughness can be modelled through a discretized multi-slice and effective medium approach, but to date, this offered mostly qualitative and not quantitative accuracy. Here we introduce an adaptive and nonlocal effective medium approach, which considers the relative size and environment of each discretized slice. We develop our model using finite-difference time-domain simulation results and demonstrate its ability to predict nanoroughness size and shape with relative errors < 3% in a variety of test systems. The accuracy of the model is directly compared to the prediction capabilities of the Bruggeman and Maxwell–Garnett models, highlighting its superiority. Our model is fully parametrized and ready to use for exploring the effects of roughness on reflectance without the need for costly 3D simulations and to be integrated into the Fresnel simulator of spectroscopic reflectance tools.
Ochratoxins are a group of mycotoxins produced as secondary metabolites by several fungi of Aspergillus and Penicillium species. Ochratoxin A (OTA) is the most toxic member of the group and can be found in a large variety of widely consumed foods, such as coffee, cocoa, wine, and flour. Reliable determination of OTA levels in food samples is therefore indispensable to ensure compliance with MRLs set by national/European regulations and minimize health risks for consumers. In the current study, a label-free biosensor based on white light reflectance spectroscopy (WLRS) for the rapid and accurate determination of OTA in cereal flour samples is demonstrated. A Si chip with a 1-μm-thick thermal SiO2 on top plays the role of transducer after the immobilization of an OTA–protein conjugate on its surface. For the assay, a mixture of an in-house-developed anti-OTA antibody with the calibrators or the samples is injected over the chip surface, followed by reaction with a secondary biotinylated antibody and streptavidin for signal amplification. The label-free, real-time monitoring of immunoreactions occurring on the SiO2/Si chip surface is achieved by recording the shift in the reflected interference spectrum caused by the immunoreactions. This shift is converted through appropriate mathematical processing to an effective biomolecular adlayer thickness. After optimization, the sensor is capable of detecting OTA in wheat flour samples at concentrations as low as 60 pg/mL within 25 min. The assay is repeatable, with intra- and inter-assay CVs ≤5.9% and ≤9.0%, respectively. The assay’s excellent analytical characteristics and short analysis time, in combination with the small size of the device, render the proposed WLRS system ideal for the quantitative determination of minute OTA levels at the point-of-need.