Michailia Angelopoulou

Dr. Michailia Angelopoulou


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 April 2021 in Sensors
Verified
Journal Article
Open access
PDF file
MAMichailia Angelopoulou
Michailia Angelopoulou
KTKonstantina Tzialla
Konstantina Tzialla
AVAngeliki Voulgari
Angeliki Voulgari
MDMary Dikeoulia
Mary Dikeoulia
IRIoannis Raptis
Ioannis Raptis
Panagiota PetrouPanagiota Petrou
Panagiota Petrou
Biosensors represent an attractive approach for fast bacteria detection. Here, we present an optical biosensor for the detection of Salmonella typhimurium lipopolysaccharide (LPS) and Salmonella bacteria in drinking water, based on white light reflectance spectroscopy. The sensor chip consisted of a Si die with a thin SiO2 layer on top that was transformed into a biosensor through the immobilization of Salmonella LPS. The optical setup included a reflection probe with seven 200 μm fibers, a visible and near-infrared light source, and a spectrometer. The six fibers at the reflection probe circumference were coupled with the light source and illuminated the biosensor chip vertically, whereas the central fiber collected the reflected light and guided it to the spectrometer. A competitive immunoassay configuration was adopted for the analysis. Accordingly, a mixture of LPS or bacteria solution, pre-incubated for 15 min, with an anti-Salmonella LPS antibody was pumped over the chip followed by biotinylated secondary antibody and streptavidin for signal enhancement. The binding of the free anti-Salmonella antibody to chip-immobilized LPS led to a shift of the reflectance spectrum that was inversely related to the analyte concentration (LPS or bacteria) in the calibrators or samples. The total assay duration was 15 min, and the detection limits achieved were 4 ng/mL for LPS and 320 CFU/mL for bacteria. Taking into account the low detection limits, the short analysis time, and the small size of the chip and instrumentation employed, the proposed immunosensor could find wide application for bacteria detection in drinking water.

11 July 2022 in Biosensors
Verified
Journal Article
Open access
PDF file
MAMichailia Angelopoulou
Michailia Angelopoulou
Panagiota PetrouPanagiota Petrou
Panagiota Petrou
KMKonstantinos Misiakos
Konstantinos Misiakos
Ioannis RaptisIoannis Raptis
Ioannis Raptis
Sotirios KakabakosSotirios Kakabakos
Sotirios Kakabakos
The consumption of water and milk contaminated with bacteria can lead to foodborne disease outbreaks. For this reason, the development of rapid and sensitive analytical methods for bacteria detection is of primary importance for public health protection. Here, a miniaturized immunosensor based on broadband Mach–Zehnder Interferometry for the simultaneous determination of S. typhimurium and E. coli O157:H7 in drinking water and milk is presented. For the assay, mixtures of bacteria solutions with anti-bacteria-specific antibodies were run over the chip, followed by solutions of biotinylated anti-species-specific antibody and streptavidin. The assay was fast (10 min for water, 15 min for milk), accurate, sensitive (LOD: 40 cfu/mL for S. typhimurium; 110 cfu/mL for E. coli) and reproducible. The analytical characteristics achieved combined with the small chip size make the proposed biosensor suitable for on-site bacteria determination in drinking water and milk samples.

3 August 2023 in Chemosensors
Verified
Journal Article
Open access
PDF file
Dimitra KourtiDimitra Kourti
Dimitra Kourti
MAMichailia Angelopoulou
Michailia Angelopoulou
Panagiota PetrouPanagiota Petrou
Panagiota Petrou
Sotirios KakabakosSotirios Kakabakos
Sotirios Kakabakos
Optical immunosensors are one of the most popular categories of immunosensors with applications in many fields including diagnostics and environmental and food analysis. The latter field is of particular interest not only for scientists but also for regulatory authorities and the public since food is essential for life but can also be the source of many health problems. In this context, the current review aims to provide an overview of the different types of optical immunosensors focusing on their application for the determination of pathogenic bacteria in food samples. The optical immunosensors discussed include sensors based on evanescent wave transduction principles including surface plasmon resonance (SPR), fiber-optic-, interferometric-, grating-coupler-, and ring-resonator-based sensors, as well as reflectometric, photoluminescence, and immunosensors based on surface-enhanced Raman scattering (SERS). Thus, after a short description of each transduction technique, its implementation for the immunochemical determination of bacteria is discussed. Finally, a short commentary about the future trends in optical immunosensors for food safety applications is provided.

26 August 2023 in Chemosensors
Verified
Journal Article
Open access
PDF file
MAMichailia Angelopoulou
Michailia Angelopoulou
Dimitra KourtiDimitra Kourti
Dimitra Kourti
MMMaria Mertiri
Maria Mertiri
Panagiota PetrouPanagiota Petrou
Panagiota Petrou
Sotirios KakabakosSotirios Kakabakos
Sotirios Kakabakos
Christos KokkinosChristos Kokkinos
Christos Kokkinos
Salmonella is one of the leading causes of foodborne illnesses worldwide, with poultry products being a major source of contamination. Thus, the detection of salmonella in commercial poultry products is crucial to minimize the effects on public health. Electrochemical sensors are promising tools for bacteria detection due to their sensitivity, simplicity, and potential for on-site analysis. In this work, a three-dimensional (3D) printed electrochemical immunosensor for the determination of Salmonella typhimurium in fresh chicken through a sandwich immunoassay employing biotinylated anti-S. typhimurium antibody followed by streptavidin labeled with Cd/Se ZnS quantum dots (QDs) is presented. The device features three carbon-black polylactic acid electrodes and a holder, and the quantification of S. typhimurium is performed by anodic stripping voltametric (ASV) determination of the Cd(II) released after acidic dissolution of the QDs. To enhance sensitivity, an electroplated bismuth film was deposited on the working electrode, achieving a detection limit of 5 cfu/mL in a total assay time of 25 min, whereas 5 h of sample pre-enrichment was required for the detection of 1 cfu/25 mL of chicken rinse and chicken broth. The method is accurate, with %recovery values ranging from 93.3 to 113% in fresh chicken samples, and repeatable with intra- and inter- assay coefficient of variations <2 and 5%, respectively, indicating the suitability of the proposed immunosensor for the detection of S. typhimurium at the point-of-need.

30 May 2023 in Biosensors
Verified
Journal Article
Open access
PDF file
MAMichailia Angelopoulou
Michailia Angelopoulou
Dimitra KourtiDimitra Kourti
Dimitra Kourti
KMKonstantinos Misiakos
Konstantinos Misiakos
Anastasios EconomouAnastasios Economou
Anastasios Economou
Panagiota PetrouPanagiota Petrou
Panagiota Petrou
Sotirios KakabakosSotirios Kakabakos
Sotirios Kakabakos
Aflatoxin M1 (AFM1) is detected in the milk of animals after ingestion of aflatoxin B1-contaminated food; since 2002, it has been categorized as a group I carcinogen. In this work, a silicon-based optoelectronic immunosensor for the detection of AFM1 in milk, chocolate milk, and yogurt has been developed. The immunosensor consists of ten Mach–Zehnder silicon nitride waveguide interferometers (MZIs) integrated on the same chip with the respective light sources, and an external spectrophotometer for transmission spectra collection. The sensing arm windows of MZIs are bio-functionalized after chip activation with aminosilane by spotting an AFM1 conjugate with bovine serum albumin. For AFM1 detection, a three-step competitive immunoassay is employed, including the primary reaction with a rabbit polyclonal anti-AFM1 antibody, followed by biotinylated donkey polyclonal anti-rabbit IgG antibody and streptavidin. The assay duration was 15 min with limits of detection of 0.005 ng/mL in both full-fat and chocolate milk, and 0.01 ng/mL in yogurt, which are lower than the maximum allowable concentration of 0.05 ng/mL set by the European Union. The assay is accurate (% recovery values 86.7–115) and repeatable (inter- and intra-assay variation coefficients <8%). The excellent analytical performance of the proposed immunosensor paves the way for accurate on-site AFM1 determination in milk.

12 November 2018 in Chemosensors
Verified
Journal Article
Open access
PDF file
MAMichailia Angelopoulou
Michailia Angelopoulou
Sotirios KakabakosSotirios Kakabakos
Sotirios Kakabakos
Panagiota PetrouPanagiota Petrou
Panagiota Petrou
The article reviews the current status of label-free integrated optical biosensors focusing on the evolution over the years of their analytical performance. At first, a short introduction to the evanescent wave optics is provided followed by detailed description of the main categories of label-free optical biosensors, including sensors based on surface plasmon resonance (SPR), grating couplers, photonic crystals, ring resonators, and interferometric transducers. For each type of biosensor, the detection principle is first provided followed by description of the different transducer configurations so far developed and their performance as biosensors. Finally, a short discussion about the current limitations and future perspectives of integrated label-free optical biosensors is provided.