Ramon Mas-Sansó

Dr. Ramon Mas-Sansó

Universitat de les Illes Balears (UIB)
orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 December 2022 in Sensors
Verified
Journal Article
Open access
PDF file
GTGuillermo del Castillo Torres
Guillermo del Castillo Torres
MRMaria Francesca Roig-Maimó
Maria Francesca Roig-Maimó
MMMiquel Mascaró-Oliver
Miquel Mascaró-Oliver
EAEsperança Amengual-Alcover
Esperança Amengual-Alcover
RMRamon Mas-Sansó
Ramon Mas-Sansó
Recognizing facial expressions has been a persistent goal in the scientific community. Since the rise of artificial intelligence, convolutional neural networks (CNN) have become popular to recognize facial expressions, as images can be directly used as input. Current CNN models can achieve high recognition rates, but they give no clue about their reasoning process. Explainable artificial intelligence (XAI) has been developed as a means to help to interpret the results obtained by machine learning models. When dealing with images, one of the most-used XAI techniques is LIME. LIME highlights the areas of the image that contribute to a classification. As an alternative to LIME, the CEM method appeared, providing explanations in a way that is natural for human classification: besides highlighting what is sufficient to justify a classification, it also identifies what should be absent to maintain it and to distinguish it from another classification. This study presents the results of comparing LIME and CEM applied over complex images such as facial expression images. While CEM could be used to explain the results on images described with a reduced number of features, LIME would be the method of choice when dealing with images described with a huge number of features.

23 March 2021 in Sensors
Verified
Journal Article
Open access
PDF file
ISIosune Salinas-Bueno
Iosune Salinas-Bueno
MRMaria Francesca Roig-Maimó
Maria Francesca Roig-Maimó
PMPau Martinez-Bueso
Pau Martinez-Bueso
KSKatia San-Sebastián-Fernández
Katia San-Sebastián-Fernández
JVJavier Varona
Javier Varona
RMRamon Mas-Sansó
Ramon Mas-Sansó
Vision-based interfaces are used for monitoring human motion. In particular, camera-based head-trackers interpret the movement of the user’s head for interacting with devices. Neck pain is one of the most important musculoskeletal conditions in prevalence and years lived with disability. A common treatment is therapeutic exercise, which requires high motivation and adherence to treatment. In this work, we conduct an exploratory experiment to validate the use of a non-invasive camera-based head-tracker monitoring neck movements. We do it by means of an exergame for performing the rehabilitation exercises using a mobile device. The experiments performed in order to explore its feasibility were: (1) validate neck’s range of motion (ROM) that the camera-based head-tracker was able to detect; (2) ensure safety application in terms of neck ROM solicitation by the mobile application. Results not only confirmed safety, in terms of ROM requirements for different preset patient profiles, according with the safety parameters previously established, but also determined the effectiveness of the camera-based head-tracker to monitor the neck movements for rehabilitation purposes.

23 February 2023 in Sensors
Verified
Journal Article
Open access
PDF file
MRMaria Francesca Roig-Maimó
Maria Francesca Roig-Maimó
ISIosune Salinas-Bueno
Iosune Salinas-Bueno
RMRamon Mas-Sansó
Ramon Mas-Sansó
JVJavier Varona
Javier Varona
PMPau Martinez-Bueso
Pau Martinez-Bueso
We developed a mobile application for cervical rehabilitation that uses a non-invasive camera-based head-tracker sensor for monitoring neck movements. The intended user population should be able to use the mobile application in their own mobile device, but mobile devices have different camera sensors and screen dimensions that could affect the user performance and neck movement monitoring. In this work, we studied the influence of mobile devices type on camera-based monitoring of neck movements for rehabilitation purposes. We conducted an experiment to test whether the characteristics of a mobile device affect neck movements when using the mobile application with the head-tracker. The experiment consisted of the use of our application, containing an exergame, in three mobile devices. We used wireless inertial sensors to measure the real-time neck movements performed while using the different devices. The results showed that the effect of device type on neck movements was not statistically significant. We included the sex factor in the analysis, but there was no statistically significant interaction between sex and device variables. Our mobile application proved to be device-agnostic. This will allow intended users to use the mHealth application regardless of the type of device. Thus, future work can continue with the clinical evaluation of the developed application to analyse the hypothesis that the use of the exergame will improve therapeutic adherence in cervical rehabilitation.

3 November 2025 in Applied Ergonomics
Verified
Journal Article
Open access
MRMaria Francesca Roig-Maimó
Maria Francesca Roig-Maimó
RMRamon Mas-Sansó
Ramon Mas-Sansó
IMIan Scott MacKenzie
Ian Scott MacKenzie
We explored the ISO 9241-411 multi-directional tapping (2D) test for evaluating computer pointing techniques. Based on Fitts' law, the test evenly distributes targets around a circular layout and requires the same movement distance between targets for all trials in a sequence. We demonstrate that this is only possible when using an odd number of targets. We reviewed 200 research papers using the 2D task and found that about a third of them use an even number of targets, and consequently report incorrect values for throughput, reinforcing the need to advertise this overlooked but relevant issue. Our findings imply that adhering to an odd number of targets and to the correct definition of movement distance ensures methodological consistency, leading to valid throughput values. Consequently, we argue for revisiting and updating the ISO 9241-411 standard to explicitly state that an odd number of targets is required for the 2D task.

11 January 2023 in Data
Verified
Journal Article
Open access
PDF file
MMMiquel Mascaró-Oliver
Miquel Mascaró-Oliver
RMRamon Mas-Sansó
Ramon Mas-Sansó
EAEsperança Amengual-Alcover
Esperança Amengual-Alcover
MRMaria Francesca Roig-Maimó
Maria Francesca Roig-Maimó
After the COVID-19 pandemic the use of face masks has become a common practice in many situations. Partial occlusion of the face due to the use of masks poses new challenges for facial expression recognition because of the loss of significant facial information. Consequently, the identification and classification of facial expressions can be negatively affected when using neural networks in particular. This paper presents a new dataset of virtual characters, with and without face masks, with identical geometric information and spatial location. This novelty will certainly allow researchers a better refinement on lost information due to the occlusion of the mask.

19 June 2024
Verified
Conference Paper
Open access
MRMaria Francesca Roig-Maimó
Maria Francesca Roig-Maimó
JVJavier Varona
Javier Varona
RMRamon Mas-Sansó
Ramon Mas-Sansó
IMIan Scott MacKenzie
Ian Scott MacKenzie
ISIosune Salinas-Bueno
Iosune Salinas-Bueno
Cervical range of motion (ROM) is a crucial aspect of assessment following a neck injury and prior to cervical rehabilitation. We explored using an exergame with a head-tracker to predict the degree of cervical ROM. Using head movement, users moved a cursor over a picture-reveal puzzle to remove tiles and reveal an underlying picture. In a within-subjects user study, we controlled mobility restriction by fitting participants with either a rigid cervical collar (severe restriction), a soft cervical collar (moderate restriction), or no collar (no restriction). We also controlled task difficulty through two levels each of number of tiles (13 × 10, 7 × 5) and gain (high, low). Selection rate by mobility restriction ranged from ≈ 30% for severe to ≈ 95% with none, and ≈ 50% for moderate. Results suggest the following ascending ranks for difficulty based on number of tiles and gain: (1) 7×5, high gain, (2) 7×5, low gain, (3) 13×10, high gain, and (4) 13×10, low gain. This ascending difficulty order is recommended for presenting the puzzles to people with cervical conditions to avoid overexertion. The collected data were also used in machine learning with a Random Forest model. Mobility restriction category (severe, moderate, none) was correctly predicted in 80.6% of 36 samples. The results are a first step in using an exergame and machine learning to automatically categorize patients according to their cervical ROM.