Cushla M. McGoverin

Dr. Cushla M. McGoverin

Department of Physics, University of Auckland, Auckland 1010, New Zealand
orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 July 2017 in Journal of Applied Microbiology
Verified
Journal Article
Open access
PDF file
FOFang Ou
Fang Ou
CMCushla M. McGoverin
Cushla M. McGoverin
Simon SwiftSimon Swift
Simon Swift
FVFrederique Vanholsbeeck
Frederique Vanholsbeeck
To evaluate a flow cytometry protocol that uses reference beads for the enumeration of live and dead bacteria present in a mixture. Mixtures of live and dead Escherichia coli with live:dead concentration ratios varying from 0 to 100% were prepared. These samples were stained using SYTO 9 and propidium iodide and 6-μm reference beads were added. Bacteria present in live samples were enumerated by agar plate counting. Bacteria present in dead samples were enumerated by agar plate counting before treatment with isopropanol. There is a linear relationship between the presented flow cytometry method and agar plate counts for live (R2 = 0·99) and dead E. coli (R2 = 0·93) concentrations of c. 104 to 108 bacteria per ml within mixtures of live and dead bacteria. Reliable enumeration of live E. coli within a mixture of both live and dead was possible for concentration ratios of above 2·5% live and for the enumeration of dead E. coli the lower limit was c. 20% dead. The ability to obtain absolute cell concentrations is only available for selected flow cytometers, this study describes a method for accurate enumeration that is applicable to basic flow cytometers without specialized counting features. By demonstrating the application of the method to count E. coli, we raised points of consideration for using this FCM counting method and aim to lay the foundation for future work that uses similar methods for different bacterial strains.

3 September 2020 in Frontiers in Microbiology
Verified
Journal Article
Open access
CMCushla M. McGoverin
Cushla M. McGoverin
JRJulia Robertson
Julia Robertson
YJYaqub Jonmohamadi
Yaqub Jonmohamadi
SSSimon Swift
Simon Swift
FVFrédérique Vanholsbeeck
Frédérique Vanholsbeeck
SYTO 9 is a fluorescent nucleic acid stain that is widely used in microbiology, particularly for fluorescence microscopy and flow cytometry analyzes. Fluorimetry-based analysis, i.e., analysis of fluorescence intensity from a bulk sample measurement, is more cost effective, rapid and accessible than microscopy or flow cytometry but requires application-specific calibration. Here we show the relevance of SYTO 9 for food safety analysis. We stained four bacterial species of relevance to food safety (Bacillus cereus, Escherichia coli, Salmonella enterica subspecies enterica ser. Typhimurium, Staphylococcus aureus) with different concentrations of SYTO 9, with and without the presence of ethylenediaminetetraacetic acid (EDTA), for varying amounts of time, to investigate the effect of these treatment parameters on fluorescence intensity. The addition of EDTA and an increased staining duration did not significantly affect fluorescence intensity, and over the bacterial cell concentration range investigated (∼105–108 CFU/ml) there was no significant difference in using 0.5 or 1 μM SYTO 9. The effect of bacterial cell concentration on fluorescence intensity was species specific. At different bacterial cell concentrations, the effect of species on fluorescence intensity is different. This interaction complicates the development of a general fluorimetry-based protocol for the determination of bacterial cell concentration in a mixed bacterial suspension, as would be expected from samples taken from food safety settings.

1 August 2021 in APL Photonics
Verified
Journal Article
Open access
PDF file
CMCushla M. McGoverin
Cushla M. McGoverin
CSCraig Steed
Craig Steed
AEAyomikun Esan
Ayomikun Esan
JRJulia Robertson
Julia Robertson
Simon SwiftSimon Swift
Simon Swift
FVFrederique Vanholsbeeck
Frederique Vanholsbeeck
Rapid identification and enumeration of bacteria are critical, given the surge of antibiotic-resistance, global exchange of food products, and the use of bacteria for bioremediation, pharmaceutical, and food production. In response, a wide range of methods are being developed that can be broadly classified as nucleic acid-based, structure-based, mass spectrometry-based, and optically based. Optical methods have generated interest given the potential for rapid, non-destructive, high-throughput, and amplification-free measurements that require minimal sample preparation. This Perspective reviews optical methods, which are applied to identification, enumeration, and greater understanding of bacteria routinely and more importantly at the cutting edge of research, with the aim of identifying gaps and opportunities for development. We have focused primarily on methods that directly measure bacteria and not their effect on the sample matrix or sensing, which requires a biorecognition element (i.e., label specific to some component of the bacterium). We identify gaps in the existing techniques and avenues for innovation. Finally, we suggest the parameters that should be considered and recorded when reporting the development of existing and new methods for bacterial characterization. This Perspective is intended for physicists interested in developing new optical methods for the study of bacteria and microbiologists in need of an optical technique for bacterial applications.

16 October 2023 in Food Control
Verified
Journal Article
Open access
JSJoy Sim
Joy Sim
YDYash Dixit
Yash Dixit
CMCushla M. McGoverin
Cushla M. McGoverin
IOIndrawati Oey
Indrawati Oey
RFRussell Frew
Russell Frew
Biniam KebedeBiniam Kebede
Biniam Kebede

26 June 2023 in Food Chemistry
Verified
Journal Article
Open access
JSJoy Sim
Joy Sim
CMCushla M. McGoverin
Cushla M. McGoverin
IOIndrawati Oey
Indrawati Oey
RFRussell Frew
Russell Frew
Biniam KebedeBiniam Kebede
Biniam Kebede
Stable isotope ratios and trace elements are well-established tools that act as signatures of the product's environmental conditions and agricultural processes; but they involve time, money, and environmentally destructive chemicals. In this study, we tested for the first time the potential of near-infrared reflectance spectroscopy (NIR) to estimate/predict isotope and elemental compositions for the origin verification of coffee. Green coffee samples from two continents, 4 countries, and 10 regions were analysed for five isotope ratios (δ13C, δ15N, δ18O, δ2H, and δ34S) and 41 trace elements. NIR (1100-2400 nm) calibrations were developed using pre-processing with extended multiplicative scatter correction (EMSC) and mean centering and partial-least squares regression (PLS-R). Five elements (Mn, Mo, Rb, B, La) and three isotope ratios (δ13C, δ18O, δ2H) were moderately to well predicted by NIR (R2: 0.69 to 0.93). NIR indirectly measured these parameters by association with organic compounds in coffee. These parameters were related to altitude, temperature and rainfall differences across countries and regions and were previously found to be origin discriminators for coffee.

28 September 2023 in Food Research International
Verified
Journal Article
Open access
JSJoy Sim
Joy Sim
YDYash Dixit
Yash Dixit
CMCushla M. McGoverin
Cushla M. McGoverin
IOIndrawati Oey
Indrawati Oey
RFRussell Frew
Russell Frew
Biniam KebedeBiniam Kebede
Biniam Kebede
The potential of using rapid and non-destructive near-infrared - hyperspectral imaging (HSI-NIR) for the prediction of an integrated stable isotope and multi-element dataset was explored for the first time with the help of support vector regression. Speciality green coffee beans sourced from three continents, eight countries, and 22 regions were analysed using a push-broom HSI-NIR (700-1700 nm), together with five isotope ratios (δ13C, δ15N, δ18O, δ2H, and δ34S) and 41 trace elements. Support vector regression with the radial basis function kernel was conducted using X as the HSI-NIR data and Y as the geochemistry markers. Model performance was evaluated using root mean squared error, coefficient of determination, and mean absolute error. Three isotope ratios (δ18O, δ2H, and δ34S) and eight elements (Zn, Mn, Ni, Mo, Cs, Co, Cd, and La) had an R2predicted 0.70 - 0.99 across all origin scales (continent, country, region). All five isotope ratios were well predicted at the country and regional levels. The wavelength regions contributing the most towards each prediction model were highlighted, including a discussion of the correlations across all geochemical parameters. This study demonstrates the feasibility of using HSI-NIR as a rapid and non-destructive method to estimate traditional geochemistry parameters, some of which are origin-discriminating variables related to altitude, temperature, and rainfall differences across origins.