Spectral sensing is increasingly used in applications ranging from industrial process monitoring to agriculture. Sensing is usually performed by measuring reflected or transmitted light with a spectrometer and processing the resulting spectra. However, realizing compact and mass-manufacturable spectrometers is a major challenge, particularly in the infrared spectral region where chemical information is most prominent. Here we propose a different approach to spectral sensing which dramatically simplifies the requirements on the hardware and allows the monolithic integration of the sensors. We use an array of resonant-cavity-enhanced photodetectors, each featuring a distinct spectral response in the 850-1700 nm wavelength range. We show that prediction models can be built directly using the responses of the photodetectors, despite the presence of multiple broad peaks, releasing the need for spectral reconstruction. The large etendue and responsivity allow us to demonstrate the application of an integrated near-infrared spectral sensor in relevant problems, namely milk and plastic sensing. Our results open the way to spectral sensors with minimal size, cost and complexity for industrial and consumer applications.
To evaluate a flow cytometry protocol that uses reference beads for the enumeration of live and dead bacteria present in a mixture. Mixtures of live and dead Escherichia coli with live:dead concentration ratios varying from 0 to 100% were prepared. These samples were stained using SYTO 9 and propidium iodide and 6-μm reference beads were added. Bacteria present in live samples were enumerated by agar plate counting. Bacteria present in dead samples were enumerated by agar plate counting before treatment with isopropanol. There is a linear relationship between the presented flow cytometry method and agar plate counts for live (R2 = 0·99) and dead E. coli (R2 = 0·93) concentrations of c. 104 to 108 bacteria per ml within mixtures of live and dead bacteria. Reliable enumeration of live E. coli within a mixture of both live and dead was possible for concentration ratios of above 2·5% live and for the enumeration of dead E. coli the lower limit was c. 20% dead. The ability to obtain absolute cell concentrations is only available for selected flow cytometers, this study describes a method for accurate enumeration that is applicable to basic flow cytometers without specialized counting features. By demonstrating the application of the method to count E. coli, we raised points of consideration for using this FCM counting method and aim to lay the foundation for future work that uses similar methods for different bacterial strains.
2 May 2019 in Analytical and Bioanalytical Chemistry
A rapid and easy method that takes advantage of an inexpensive and portable fibre-based spectroscopic system (optrode) to determine the ratio of live to dead bacteria is proposed. Mixtures of live and dead Escherichia coli with proportions of live:dead cells varying from 0 to 100% were stained using SYTO 9 and propidium iodide (PI) and measured using the optrode. We demonstrated several approaches to obtaining the proportions of live:dead E. coli in a mixture of both live and dead, from analyses of the fluorescence spectra collected by the optrode. To find a suitable technique for predicting the percentage of live bacteria in a sample, four analysis methods were assessed and compared: SYTO 9:PI fluorescence intensity ratio, an adjusted fluorescence intensity ratio, single-spectrum support vector regression (SVR) and multi-spectra SVR. Of the four analysis methods, multi-spectra SVR obtained the most reliable results and was able to predict the percentage of live bacteria in 108 bacteria/mL samples between c. 7 and 100% live, and in 107 bacteria/mL samples between c. 7 and 73% live. By demonstrating the use of multi-spectra SVR and the optrode to monitor E. coli viability, we raise points of consideration for spectroscopic analysis of SYTO 9 and PI and aim to lay the foundation for future work that uses similar methods for different bacterial species.
A rapid, cost-effective and easy method that allows on-site determination of the concentration of live and dead bacterial cells using a fibre-based spectroscopic device (the optrode system) is proposed and demonstrated. Identification of live and dead bacteria was achieved by using the commercially available dyes SYTO 9 and propidium iodide, and fluorescence spectra were measured by the optrode. Three spectral processing methods were evaluated for their effectiveness in predicting the original bacterial concentration in the samples: principal components regression (PCR), partial least squares regression (PLSR) and support vector regression (SVR). Without any sample pre-concentration, PCR achieved the most reliable results. It was able to quantify live bacteria from 108 down to 106.2 bacteria/mL and showed the potential to detect as low as 105.7 bacteria/mL. Meanwhile, enumeration of dead bacteria using PCR was achieved between 108 and 107 bacteria/mL. The general procedures described in this article can be applied or modified for the enumeration of bacteria within populations stained with fluorescent dyes. The optrode is a promising device for the enumeration of live and dead bacterial populations particularly where rapid, on-site measurement and analysis is required.
For decades, near-infrared (NIR) spectroscopy has been a valuable tool for material analysis in a variety of applications, ranging from industrial process monitoring to quality assessment. Traditional spectrometers are typically bulky, fragile and expensive, which makes them unsuitable for portable and in-field use. Thus, there is a growing interest for miniaturized, robust and low-cost NIR sensors. In this study, we demonstrate a handheld NIR spectral sensor module, based on a fully-integrated multipixel detector array, sensitive in the 850–1700 nm wavelength range. Differently from a spectrometer, the spectral sensor measures a limited number of NIR spectral bands. The capabilities of the spectral sensor module were evaluated alongside a commercially available portable spectrometer for two application cases: to quantify the moisture content in rice grains and to classify plastic types. Both devices achieved the two sensing tasks with comparable performance. Moisture quantification was achieved with a root mean square error (RMSE) prediction of 1.4% and 1.1% by the spectral sensor and spectrometer, respectively. Classification of the plastic type was achieved with a prediction accuracy on unknown samples of 100% and 96.4% by the spectral sensor and spectrometer, respectively. The results from this study are promising and demonstrate the potential for the compact NIR modules to be used in a variety of NIR sensing applications.