Jacopo Colombo

Dr. Jacopo Colombo

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 November 2021 in Materials
Verified
Journal Article
Open access
PDF file
Gianmario SchieranoGianmario Schierano
Gianmario Schierano
DBDomenico Baldi
Domenico Baldi
BPBruno Peirone
Bruno Peirone
Mitzy Mauthe von DegerfeldMitzy Mauthe von Degerfeld
Mitzy Mauthe von Degerfeld
RNRoberto Navone
Roberto Navone
Giuliana MuzioGiuliana Muzio
Giuliana Muzio
Background. A new instrumentation exploiting magneto-dynamic technology (mallet) proposed for implant site preparation was investigated. Methods. In the tibias of three minipigs, two sites were prepared by mallet and two by drill technique. Primary stability (ISQ) was detected after implant positioning (T0) and at 14 days (T14). X-rays and computed tomography were performed. At T14, bone samples were utilized for histological and biomolecular analyses. Results. In mallet sites, histological evaluations evidenced a significant increase in the newly formed bone, osteoblast number, and a smaller quantity of fibrous tissue. These results agree with the significant BMP-4 augmentation and the positive trend in other osteogenic factors (biological and radiological investigations). Major, albeit IL-10-controlled, inflammation was present. For both techniques, at T14 a significant ISQ increase was evidenced, but no significant difference was observed at T0 and T14 between the mallet and drill techniques. In mallet sites, lateral bone condensation was observed on computed tomography. Conclusions. Using biological, histological, clinical, and radiological analyses, this study first shows that the mallet technique is effective for implant site preparation. Based on its ability to cause osseocondensation and improve newly formed bone, mallet technology should be chosen in all clinical cases of poor bone quality.

21 December 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
DBDomenico Baldi
Domenico Baldi
LGLuisa De Giorgis
Luisa De Giorgis
Maria MeniniMaria Menini
Maria Menini
FMFranco Motta
Franco Motta
JCJacopo Colombo
Jacopo Colombo
Professional oral hygiene is fundamental to prevent peri-implant disease. Appropriate instruments should be used in patients with restorations supported by dental implants: they should be effective in deposits removal without damaging the implant components surface. The aim of the present study is to investigate and summarize the results regarding the efficacy of oral hygiene techniques described in the literature in the last 10 years in patients rehabilitated with dental implants not affected by perimplantitis. The present systematic review was conducted according to guidelines reported in the indications of the Preferred Reporting Items for Systematic Review and Meta-Analysis (PRISMA). The focused question was: “Which are the most effective instruments for professional oral hygiene on implants not affected by perimplantitis?”. The initial database search yielded a total of 934 entries found in PubMed®/MEDLINE and Cochrane Library. After full text review and application of the eligibility criteria, the final selection consisted of 19 articles. The risk of bias of included studies was assessed using the Newcastle Ottawa scale (NOS) and the Cochrane Handbook for Systematic Reviews of Interventions. Curette, scalers and air polishing were the devices most frequently investigated in the included studies. In particular, glycine powder air polishing appeared to be significantly effective in reducing peri-implant inflammation and plaque around implants. The application of the more recent erythritol powder air polishing also yielded good clinical outcomes. Further studies are needed to improve the knowledge on the topic in order to develop standardized protocols and understand the specific indications for different types of implant-supported rehabilitations.

1 January 2020 in BioMed Research International
Verified
Journal Article
Open access
PDF file
DBD. Baldi
D. Baldi
JCJacopo Colombo
Jacopo Colombo
FMF. Motta
F. Motta
AZA. Zillio
A. Zillio
NSN. Scotti
N. Scotti
Replacing a single tooth in the anterior maxilla is one of the greatest challenges in dentistry. Both functional and aesthetic results are to be strictly pursued. Planning and executing such a case through a totally digital methodology eventually guarantee many advantages, above all patient’s operative and postoperative comfort. To ascertain this, a BOP analysis was performed which allowed us to evaluate soft tissues health, and more; crestal bone resorption was measured to evaluate hard tissues stability. This assumption was studied through four cases in which patients were alternatively treated with analogic and digital techniques. Four homogeneous patients were recruited. They all needed to extract one of the upper incisors, due to different clinical reasons, and then to replace it with an implant. Each patient was treated with an immediate postextractive implant which was immediately loaded, and finally, analogical and digital techniques were compared. All patients underwent a preoperative CBCT examination. After surgery, patients were checked by the surgeon after 10 days and one month to evaluate the progress of healing and to exclude any prosthetic problem. At 6 months (T1), one year (T2), and three years (T3), intraoral x‐rays were performed using customized centring devices, according to the parallel beam technique. All data have been collected in a table and statistically processed; mean and standard deviation were measured. All patients entered an oral hygiene program with six months recall. Dental hygienist checked the BOP at T1, T2, and T3. At every step, similar levels of BOP were recorded. About interproximal bone loss, all patients showed an initial moderate loss (between T1 and T2), followed by stable values between T2 and T3. Despite the important limitations of a study with few cases, these results show a similar outcome comparing digital and analogical methods.

1 March 2020 in Minerva Dental and Oral Science
Verified
Journal Article
Closed access
DBDomenico Baldi
Domenico Baldi
JCJacopo Colombo
Jacopo Colombo
SVSimone Verardi
Simone Verardi
ARAlberto Rebaudi
Alberto Rebaudi
FRFederico Rebaudi
Federico Rebaudi
CMChristian Makary
Christian Makary
BACKGROUND: Evidence shows lower chance for osseointegration of implants without sufficient primary stability. The present retrospective study observed bone level conical screw implants with textured surface without primary stability. METHODS: Twenty-six Stark conical screw implants, with V-Blast (Vanish Blast) surface treatment were placed with low primary stability, (insertion torque lower than 10 N/cm and visible mobility at lateral load of 250 g). A soft diet was prescribed. osseointegration was assessed applying 30 Ncm of reverse torque 6 months after placement. RESULTS: The 26 implants that did not achieve primary stability still had a survival rate of 96% after the observation period and were classified as successful according with ICOI Pisa consensus conference success, survival, failure classification.96% of the implants showed clinical osteointegration and were successfully restored. After 12 months, all implants remained functional. CONCLUSIONS: It can be concluded that bone-level implants with V-Blast surface in absence of functional loading are able to achieve osteointegration, even with low primary stability.

1 February 2020 in Minerva Dental and Oral Science
Verified
Journal Article
Closed access
DBDomenico Baldi
Domenico Baldi
JCJacopo Colombo
Jacopo Colombo
MRMassimo Robiony
Massimo Robiony
MMMaria Menini
Maria Menini
EBElisa Bisagni
Elisa Bisagni
PPPaolo Pera
Paolo Pera
BACKGROUND: The purpose of this study was to analyze pulpal temperature increase generated by prosthodontic margin repositioning and finishing with ultrasonic and rotating instruments. The temperature changes recorded were also correlated with the residual dentin thickness. METHODS: A sample of 32 human extracted molars was selected. The teeth were endodontically treated and prepared with prosthetic round chamfer preparation. Then, they were inserted in plaster cubes up to the cement-enamel junction, leaving the apical portion pervious for inserting the thermocouple probe. The conventional technique, which involves the use of a high-speed contra-angle handpiece, was compared with an ultrasonic method (Crown Prep, Mectron, Carasco, Italy). For margin repositioning and finishing, two walls were randomly selected for each tooth: one was included in the test group and cut with the piezoelectric instrument (Multipiezo Touch TipHolder DB2, Mectron, Carasco, Genoa, Italy), the other one was inserted in the control group and cut with the high speed contra-angle handpiece (Kavo, Biberach, Germany). To standardize the operator-dependent parameters, it was used a mechanical arm controlled by a computer. These parameters were the pressure exerted on the dental wall, the cutting length and the time required for margin repositioning and finishing. For both test and control group, test phase consisted in a first stage of margin repositioning using an ultrasound tip or a diamond bur with a greater granulometry (120 mu m for the ultrasound tip and 125 mu m for the diamond bur), followed by a second finishing step conducted by an ultrasound tip or a diamond bur with smaller granulometry (60 mu m for the ultrasound tip and 30 mu m for the diamond bur). During these stages the intrapulpal temperature was recorded thanks to a thermocouple. Before and after these steps, the thickness of the remaining dental walls was measured with a caliber. RESULTS: The average pulpal temperature increase was 5.03 +/- 0.98 degrees C for the ultrasonic preparation (test group) and 3.55 +/- 0.95 degrees C for the conventional technique (control group). The difference was statistically significant (P value <0.001). However, neither of the instruments reached the critical level of 5.5 degrees C reported in the literature. The mean initial dentin thicknesses was 1.82 +/- 0.47 mm for the control group and 1.59 +/- 0.54 mm for the test group but the analysis of the residual dentin thicknesses revealed a greater reduction of the walls worked up with high speed contra-angle handpiece (mean 0.9 +/- 0.5 mm), which was therefore more aggressive than the ultrasonic instrument (mean 1.1 +/- 0.5 mm). A very weak negative correlation was present between the thickness of the wall at baseline and the increment of temperature. CONCLUSIONS: Within limitations of this study, temperature increasing of ultrasonic instruments shows a statistical difference related to rotary ones. But, as literature shows, the ultrasonic advantages are margin precision, preservation of soft tissues and reduction of operating times. Furthermore, in relation with results of this study, they could be considered safe for pulp vitality because the increase in pulpal temperature is similar to traditional instruments and it does not exceed the critical level of 5.5 degrees C.

1 March 2020 in Minerva Dental and Oral Science
Verified
Journal Article
Closed access
DBDomenico Baldi
Domenico Baldi
JCJacopo Colombo
Jacopo Colombo
CSClaudio Stacchi
Claudio Stacchi
MMMaria Menini
Maria Menini
AOAmalia Oronos
Amalia Oronos
PPPaolo Pera
Paolo Pera
BACKGROUND: Ultrasonic devices have a lot of dental application specially in hygiene and surgery. However there are some disadvantages like cut slowness and heat production. Prosthodontics application is less investigated. In particular the heat production could be an important factor for the clinician. In fact more than 5.5 degrees C temperature increasing could determine pulp necrosis during tooth preparation. The aim of this study is to investigate the increasing of temperature during finishing line repositioning and polishing phases using ultrasounds inserts and to verify if it remains within the limit of 5.5 degrees C. METHODS: A sample of 32 human molars (extracted for periodontal reasons) was selected. The teeth were endodontically treated and prepared with burs in order to obtain a prosthetic round chamfer preparation, leaving the apical portion pervious for inserting the thermocouple probe. Then, they were inserted in plaster cubes up to the cement-enamel junction. A wall has been selected for each tooth for margin repositioning and finishing and prepared with the piezoelectric instrument (Multipiezo Touch with TipHolder DB2, Mectron, Carasco, Genoa, Italy). A mechanical arm was used to standardize the operator-dependent parameters. These parameters were: the pressure exerted on the dental wall, the cutting length and the time required for margin repositioning and finishing. The test phase consisted in a first stage of margin repositioning using an regular ultrasound tip with a diamond grain of 120 micron (DB120, Mectron, Carasco, Italy) (group 1), followed by a second finishing step conducted by a extra fine ultrasound tip with a diamond grain of 60 micron (DB60, Mectron, Carasco, Italy) (group 2). Each test lasted 60 seconds: this was the time that the mechanical arm needed to accomplish 32 rides. During these stages the intrapulpal temperature has been recorded thanks to a thermocouple. The obtained temperature data were analyzed by Kruskal-Wallis test and Mann-Withney post-hoc test, without Bonferroni correction (P<0.001). RESULTS: The average pulpal temperature increase was 4.65 degrees C with a standard deviation of 0.99 degrees C for the DB 120 ultrasonic tip and 5.40 degrees C with a standard deviation of 0.84 degrees C for the DB 60 ultrasonic tip. However, neither of the instruments reach the medium critical level of 5.5 degrees C reported in the literature, there are some single values who exceed it. There is statistically significant difference using tips with different granulometries within the two groups (P value =0.013). CONCLUSIONS: Ultrasonic tools are very performing to achieve results in repositioning and polishing of prepared tooth. The in-vitro analysis show that the pulp temperature increasing remains within the safe limits literature shows. It is important underline the polishing phase is the most critical and the clinicians have to pay attention to irrigation and pression to avoid pulp damages. Additional clinical studies have to be performed to confirm these results.