The aim of the present systematic review was to investigate the effect of residual bone height (RBH) and vertical bone gain on new bone formation (NBF) and graft shrinkage after lateral sinus lifts using different biomaterials. Methods: An electronic search was conducted on three databases to identify randomized controlled trials (RCTs) published until January 2021 with at least one follow-up at 6 months and at least five patients treated, comparing biomaterials used for maxillary sinus augmentation with a lateral approach. Graft volumetric changes, RBH, vertical bone gain, implant failure, and post-operative complications were evaluated. The risk of bias was assessed using the Cochrane tool. Results: We used 4010 identified studies, of which 21 were RCTs. Overall, 412 patients and 533 sinuses were evaluated. Only three publications had an overall low risk of bias. After 6 months, xenograft (XG) showed the least volume reduction (7.30 ± 15.49%), while autogenous graft (AU) was the most reabsorbed (41.71 ± 12.63%). NBF appeared to not be directly correlated with RBH; on the contrary, the overall linear regression analysis showed that NBF significantly decreased by 1.6% for each mm of postoperative vertical graft gain. This finding suggests that the greater the augmentation, the lower the NBF. A similar tendency, with a regression coefficient even higher than the overall one, was also observed with alloplast (AP) and XG. Conclusions: The present results suggested that NBF was essentially independent of preoperative bone height. On the contrary, the smaller the volume was of the graft placed, the higher the amount of new bone formed, and the smaller the graft shrinkage was. Minimizing the augmentation volume might be beneficial to graft healing and stability especially when using AP and XG.
Tilted implants have been proposed as an alternative to traditional protocols in the rehabilitation of edentulous maxillae. The aim of this meta-analysis was to evaluate the outcomes of upright and tilted implants supporting full-arch fixed dentures for the immediate rehabilitation of edentulous maxillae, after at least 1 year of function. An electronic search of databases and a hand search of relevant journals in oral implantology were performed according to PRISMA guidelines through August, 2011. The literature search yielded 1,069 articles. Eleven articles were available for analysis. A total of 1,623 implants (778 tilted, 845 upright) were inserted into the maxillae of 324 patients. Seventeen tilted (2.19%) and 16 upright implants (1.89%) failed during the first year. No significant difference in failure rate was found between tilted and upright implants (p value = 0.52). Marginal bone level results were obtained from 6 studies. A non-significant mean difference between tilted and upright implants was found with regard to bone loss. Tilted implants demonstrated a favorable short-term prognosis in full-arch immediate loading rehabilitations of the maxillae. Randomized long-term trials are needed to better elucidate long-term success of tilted vs. upright-positioned implants.
The purpose of this systematic review was to investigate the clinical outcomes of frameworks made of different materials in patients with implant-supported full-arch prostheses. A literature search was conducted on MEDLINE, Scopus and Cochrane Library, until the 1st of March 2021, with the following search terms: framework or substructure combined with “dental implants”. The outcomes evaluated were: implant and prosthesis survival, bone resorption, biological and technical complications. The Cochrane Handbook for Systematic Reviews of Interventions was employed to assess the risk of bias in randomized clinical trials. The Newcastle–Ottawa quality assessment scale was used for non-randomized studies. In total, 924 records were evaluated for title and abstract, and 11 studies were included in the review: 4 clinical randomized trials and 7 cohort studies. The framework materials investigated were: gold alloy, titanium, silver-palladium alloy, zirconia and polymers including acrylic resin and carbon-fiber-reinforced composites. High implant and prosthetic cumulative survival rates were recorded by all included studies. Various materials and different fabrication techniques are now available as alternatives to traditional cast metal frameworks, for full-arch implant-supported rehabilitations. Further long-term studies are needed to validate the use of these materials and clarify their specific clinical indications and manufacturing protocols to optimize their clinical outcomes.
Objectives: The aim of this study was to systematically revise the state of art of the accuracy of digital and conventional impressions in clinical full-arch scenarios. Methods: Electronic and manual searches were conducted up to December 2024. Only trials comparing the accuracy of digital versus conventional impressions were selected by two independent reviewers. Accuracy was evaluated by analysing the fit of the prostheses obtained through conventional workflows and those obtained from digital workflows using intraoral scanners. Alternatively, accuracy was assessed by comparing the standard tessellation language data acquired from intraoral scanning with those obtained from scanning the physical model. The risk of bias was assessed using the Quality Assessment of Diagnostic Accuracy Studies tool. Meta-analysis was conducted to pool the mean differences from the included studies, with heterogeneity tested by Cochran’s Q test and quantified by the I2 index. Results: We included 9 relevant studies from a total of 2535 identified studies. The risk of bias was evaluated as low, and the main results of all the included articles reported similar accuracy between digital and conventional impressions. Random effects meta-analysis resulted in a pooled mean difference of 152.46 (95% C.I. = 76.46–228.46, p-value < 0.001, I2 = 93.48%). Conclusions: In conclusion, the results of the present systematic review reveal contradictory findings regarding the accuracy of digital impressions. However, most studies analysing the clinical performance of prostheses obtained through digital impressions suggest that their accuracy falls within clinically acceptable thresholds. Future research should report comparable outcomes and focus attention on linear deviations, comparing differences between conventional and digital impressions not in absolute terms, but relative to the distance measured.
Oral squamous cell carcinoma (OSCC) is a widespread malignancy with high mortality. In particular, a delay in its diagnosis dramatically decreases the survival rate. The aim of this systematic review was to investigate and summarize clinical results in the literature, regarding the potential use of salivary microRNAs (miRNAs) as diagnostic and prognostic biomarkers for OSCC patients. Twelve papers were selected, including both case–control and cohort studies, and all of them detected significantly dysregulated miRNAs in OSCC patients compared to healthy controls. Based on our results, salivary miRNAs might provide a non-invasive and cost-effective method in the diagnosis of OSCC, and also to monitor more easily its evolution and therapeutic response and therefore aid in the establishment of specific therapeutic strategies.
Background: Ultraviolet (UV) and non-thermal plasma functionalization are surface treatment modalities that seem able to improve osseointegration. The aim of this systematic review and meta-analysis is to assess the effect of the two methods and possible differences. Materials and Methods: The systematic research of pre-clinical animal studies was conducted up to May 2020 in the databases PubMed/Medline, Scopus and the Cochrane Lybrary. A meta-analysis was performed by using the DerSimonian–Laird estimator in random-effects models. Results: Through the digital search, 518 articles were identified; after duplicate removal and screening process 10 papers were included. Four studies evaluating UV treatment in rabbits were included in the meta-analysis. The qualitative evaluation of the included studies showed that both UV photofunctionalization and non-thermal plasma argon functionalization of titanium implant surfaces might be effective in vivo to improve the osseointegration. The meta-analysis on four studies evaluating UV treatment in rabbits showed that bone to implant contact values (expressed as standardized mean differences and raw mean differences) were significantly increased in the bio-activated groups when follow-up times were relatively homogeneous, although a high heterogeneity (I2 > 75%) was found in all models. Conclusions: The present systematic review and meta-analysis on pre-clinical studies demonstrated that chair-side treatment of implants with UV or non-thermal plasma appear to be effective for improving osseointegration. This systematic review supports further clinical trials on this topic.