Luisa De Giorgis

Dr. Luisa De Giorgis


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 December 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
DBDomenico Baldi
Domenico Baldi
LGLuisa De Giorgis
Luisa De Giorgis
Maria MeniniMaria Menini
Maria Menini
FMFranco Motta
Franco Motta
JCJacopo Colombo
Jacopo Colombo
Professional oral hygiene is fundamental to prevent peri-implant disease. Appropriate instruments should be used in patients with restorations supported by dental implants: they should be effective in deposits removal without damaging the implant components surface. The aim of the present study is to investigate and summarize the results regarding the efficacy of oral hygiene techniques described in the literature in the last 10 years in patients rehabilitated with dental implants not affected by perimplantitis. The present systematic review was conducted according to guidelines reported in the indications of the Preferred Reporting Items for Systematic Review and Meta-Analysis (PRISMA). The focused question was: “Which are the most effective instruments for professional oral hygiene on implants not affected by perimplantitis?”. The initial database search yielded a total of 934 entries found in PubMed®/MEDLINE and Cochrane Library. After full text review and application of the eligibility criteria, the final selection consisted of 19 articles. The risk of bias of included studies was assessed using the Newcastle Ottawa scale (NOS) and the Cochrane Handbook for Systematic Reviews of Interventions. Curette, scalers and air polishing were the devices most frequently investigated in the included studies. In particular, glycine powder air polishing appeared to be significantly effective in reducing peri-implant inflammation and plaque around implants. The application of the more recent erythritol powder air polishing also yielded good clinical outcomes. Further studies are needed to improve the knowledge on the topic in order to develop standardized protocols and understand the specific indications for different types of implant-supported rehabilitations.

Verified
Journal Article
Open access
PDF file
LGLuisa De Giorgis
Luisa De Giorgis
Paolo PescePaolo Pesce
Paolo Pesce
FBFabrizio Barberis
Fabrizio Barberis
ALAlberto Lagazzo
Alberto Lagazzo
Francesco PeraFrancesco Pera
Francesco Pera
Maria MeniniMaria Menini
Maria Menini
Background: Fiber-reinforced composites (FRCs) have been proposed as an alternative to traditional metal alloys for the realization of frameworks in full-arch implant-supported prostheses. The aim of the present in vitro study was to evaluate the deflection under load of seven prostheses endowed with frameworks made of different materials, including different types of fiber-reinforced composites (FRCs). Methods: A master cast with four implant analogues in correspondence with the two lateral incisors and the two first molars was used to create full-arch fixed prostheses with the same shape and different materials. Prostheses were made of the following different materials (framework+veneering material): gold alloy+resin (Au+R), titanium+resin (Ti+R), FRC with multidirectional carbon fibers+resin (ICFRC+AR), FRC with unidirectional carbon fibers+composite (UCFRC+C), FRC with glass fibers+resin (GFRC+AR), FRC with glass fibers+composite (GFRC+C), and resin (R, fully acrylic prosthesis). Flexural tests were conducted using a Zwick/Roell Z 0.5 machine, and the deflection of the lower surface of the prosthesis was measured in order to obtain load/deflection graphs. Results: Greater rigidity and less deflection were recorded for UCFRC+C and GFRC+C, followed by Ti+R and Au+R. The greatest deformations were observed for resin alone, ICFRC+R, and GFRC+R. The results were slightly different in the incisal region, probably due to the greater amount of veneering material in this area. Conclusions: When used to realize full-arch frameworks, Au and Ti allow for predictable mechanical behavior with gradual deformations with increasing load. UCFRC also demonstrated good outcomes and less deflection than ICFRCs when loaded. The GFRC full-arch framework may be a valid alternative, although it showed greater deflections. Further studies are needed in order to evaluate how different prosthesis designs and material thicknesses might affect the outcomes.

2 February 2022 in Materials
Verified
Journal Article
Open access
PDF file
DBDomenico Baldi
Domenico Baldi
JCJacopo Colombo
Jacopo Colombo
DBDomenico Baldi
Domenico Baldi
LGLuisa De Giorgis
Luisa De Giorgis
FMFranco Motta
Franco Motta
Gianmario SchieranoGianmario Schierano
Gianmario Schierano
The use of new prosthetic materials makes it necessary to establish adequate hygienic protocols. It was decided to make prosthetic crowns from four different materials: composite, lithium disilicate, metal ceramic, and zirconium, and to evaluate the effects on the surfaces of four different instruments through SEM and roughness analysis: manual steel curette, manual titanium curette, ultrasonic steel insert, and ultrasonic peek insert. Forty crowns were made, ten of each type of material. For each material, five crowns were manually instrumented with steel inserts (curette 11-12, PDT, Missoula, MT, USA) and titanium (Wingrove 3-4, PDT, Missoula, MT, USA) on the lingual and buccal surfaces, respectively, and the other five crowns were instrumented with an ultrasonic peek insert (ICS-IC1, Mectron, Carasco, Italy) on the buccal surface and steel (PS, EMS, Nyon, Switzerland) on the lingual surface. At this point, surface roughness analysis was carried out. The data were analyzed with a Kolmogorov–Smirnov test. Therefore, it was decided to conduct two analyses with a Kruskal–Wallis test and Bonferroni post hoc test. Then, the instrumented crowns were analyzed by SEM. The analysis of the data shows that the highest average roughness was within the composite group, while the best material appeared to be disilicate. Significant differences existed between the groups, between the materials, and between the different instruments (p-value < 0.05). In the qualitative analysis carried out by SEM, the classic steel insert eliminated the residues of golden finishing. The peek insert created alterations on all tested surfaces. The steel curette did not create particular problems, with the exception of zirconium, where it was possible to observe some scratch lines. Instrumentation with the titanium curette created deeper incisions than the steel curette in the composite and disilicate. The best results came from the ultrasonic steel insert, while the best material appeared to be disilicate.

1 November 2025 in Minerva Dental and Oral Science
Verified
Journal Article
Closed access
DBDomenico Baldi
Domenico Baldi
JCJacopo Colombo
Jacopo Colombo
ECElena Cassinotto
Elena Cassinotto
FBFrancesco Bagnasco
Francesco Bagnasco
LGLuisa De Giorgis
Luisa De Giorgis
MMMaria Menini
Maria Menini
The purpose of the study is to evaluate the use of a magnetodynamic instrument (Magnetic Mallet®, Metaergonomica, Turbigo, Milan, Italy) to perform a horizontal bone expansion in edentulous sites that need to be rehabilitated with a dental implant. A sample of 15 patients, 11 men and 4 women, age between 39 and 78 years, was analyzed. A total of 18 conical-shaped implants with a diameter of 3.80 mm and a length between 10 and 11.5 mm were inserted in the maxillary region in the area between the lateral incisor and the first upper molar. The patients were treated by two different surgeons. Bone thickness was measured through CBCT before treatment and at 3 months post-surgery. No implant failed and all of them achieved a correct osseointegration. The average pre-surgery bone thickness was 4.36±0.70 mm, it changed to 5.58±1.11 mm after using the Magnetic Mallet®, finally stabilized at 6.72±1.24 mm with the insertion of the implant. CBCT examination revealed a statistically significant difference in mean bone thickness before treatment and at 3 months post-surgery with a mean bone thickness of respectively 4.39±0.60 mm and 6.97±1.25 mm. Significantly different outcomes were obtained by operators with a different learning curve. At 3 months of follow-up, the Magnetic Mallet® proved to be a useful tool in the horizontal expansion of the atrophic upper jaw bone crest, along with the preparation of the implant site. A learning curve is necessary to optimize the clinical outcomes. Further studies are needed with a larger patient cohort and a longer follow-up to confirm the present results.

26 July 2024 in Preprints.org
Verified
Preprint
Open access
PDF file
DBDomenico Baldi
Domenico Baldi
FBFrancesca Baldi
Francesca Baldi
FGFederica Giordano
Federica Giordano
LGLuisa De Giorgis
Luisa De Giorgis
FBFrancesco Bagnasco
Francesco Bagnasco
JCJacopo Colombo
Jacopo Colombo
Tooth extraction techniques have been refined over the years in order to be less traumatic and better preserve alveolar bone. A recently introduced extraction method involves the use of the Magnetic Mallet®, which allows the clinician to be more precise, faster and less traumatic. The aim of the present study was to clinically evaluate whether extractions performed by means of the Magnetic Mallet® can lead to less bucco-lingual bone resorption. Between February 2023 and June 2023, 9 patients with an average age of 62 years underwent 29 extractions using the Magnetic Mallet®. Sectoral CBCTs were performed in order to measure bucco-lingual bone thickness at time 0 (T0, before extraction) and 3 months after extraction (T3M). All the extractions were performed by 2 different expert operators using exclusively the magnetic mallet. For statistical analysis, a two-sample t-test was performed between the measurements taken at T0 and those taken at T3M in the 29 dental elements and between the difference in bone loss among the 2 different clinicians. 22 teeth were extracted in the upper jaw and 7 in the lower jaw. The average degree of mobility was 1. The average degree of force impressed by the instrument to extract the teeth was 2, while the average frequency of blows administered was 7. The average time taken for the extractions was 3½ minutes. After 4 months, the mean bucco-lingual bone resorption was 1.54 mm (SD: +-). The difference of bucco-lingual bone thickness between T0 and T3 was significant at an alpha significance level of 0.01. No difference were found in bone resorption based on the clinician. The use of the Magnetic Mallet® during tooth extraction led to less bucco-lingual bone resorption in the 3 months following dental extraction, compared to the traditional use of manual hammers, chisels and levers.

18 November 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
DBDomenico Baldi
Domenico Baldi
FBFrancesca Baldi
Francesca Baldi
FGFederica Giordano
Federica Giordano
LGLuisa De Giorgis
Luisa De Giorgis
FBFrancesco Bagnasco
Francesco Bagnasco
JCJacopo Colombo
Jacopo Colombo
Background: Tooth extraction techniques have been refined over the years in order to be less traumatic and to better preserve alveolar bone. A recently introduced extraction method involves the use of the Magnetic Mallet®, which allows clinicians to be more precise and perform extractions faster. Moreover, the instrument enables the procedure to be less traumatic for patients. The aim of the present study was to clinically evaluate whether extractions performed using the Magnetic Mallet® can lead to less buccolingual bone resorption. Methods: Between February 2023 and June 2023, nine patients with an average age of 62 years underwent 29 extractions using the Magnetic Mallet®. Sectorial CBCTs were performed in order to measure buccolingual bone thickness at time 0 (T0, before extraction) and 3 months after extraction (T3M). All the extractions were performed by two different expert operators exclusively using the Magnetic Mallet®. For statistical analysis, a two-sample t-test was performed to determine the difference between the measurements taken at T0 and those taken at T3M in the 29 dental elements and the difference in bone loss between the surgeries conducted by the two clinicians. Results: A total of 22 teeth were extracted in the upper jaw and 7 in the lower jaw. The average degree of mobility was 1. The average degree of force impressed by the instrument to extract the teeth was 2, while the average frequency of blows administered was 7. The average time taken for the extractions was 3½ min. After 3 months, the mean buccolingual bone resorption was 1.54 mm (SD: ±). The difference in buccolingual bone thickness between T0 and T3 was significant at an alpha significance level of 0.01. No difference in bone resorption was found between the surgeries conducted by the two clinicians. Conclusions: The use of the Magnetic Mallet® results in bone loss in the buccolingual direction comparable with existing data in the literature on healing the post-extraction socket. This tool seems to be predictable in producing the same results between different operators.