Marco Aurélio Oliveira Schroeder

Dr. Marco Aurélio Oliveira Schroeder

Federal University of São João del-Rei
orcid

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 January 2004 in Journal of Geophysical Research: Atmospheres
Verified
Journal Article
Open access
PDF file
SVSilvério Visacro
Silvério Visacro
ASAmilton Soares
Amilton Soares
Marco Aurélio Oliveira SchroederMarco Aurélio Oliveira Schroeder
Marco Aurélio Oliveira Schroeder
LCLuiz C. L. Cherchiglia
Luiz C. L. Cherchiglia
VSVander José de Sousa
Vander José de Sousa
Most of the available data concerning lightning current parameters were obtained by means of measurements made in temperate regions in the Northern Hemisphere. Considering the influence of regional aspects on such parameters, the need for references concerning lightning protection practices specifically in tropical zones requires dedicated data. An experimental investigation program has been carried on in Brazil since 1971 in order to provide data for characterization of local lightning current parameters. The authors of the present work are involved in that research. With such purpose, they have evaluated a significant amount of data, obtained by means of measurements taken at an instrumented tower located at “Morro do Cachimbo” Station, in Southeastern Brazil. The lightning current wave registers correspond to 157 strokes, which were measured during 13 years at the station. In this paper, the authors present a statistical evaluation of measured current waves, with particular interest in front wave parameters. The considered parameters (peak current, front duration and front steepness) are compared with those traditionally presented in literature. The cumulative frequency distributions and the correlation coefficients between parameters were determined. One main result was derived from this work, concerning the negative downward discharges: the median (and average) value of current peak measured at tower basis was found to be around 50% and 30% higher, respectively for the first and subsequent strokes, than the usual Berger references measured at tower top.

20 November 2014 in IEEE Transactions on Electromagnetic Compatibility
Verified
Journal Article
Closed access
SVSilverio Visacro
Silverio Visacro
RARafael Alipio
Rafael Alipio
CPClever Pereira
Clever Pereira
MGMiguel Guimaraes
Miguel Guimaraes
Marco Aurélio Oliveira SchroederMarco Aurélio Oliveira Schroeder
Marco Aurélio Oliveira Schroeder
The response of grounding grids subjected to currents with typical waveforms of first and subsequent lightning return strokes is analyzed, based on experimental and simulated results. Parameters, which characterize this response, such as the grounding potential rise, impulse impedance, impulse coefficient, and effective grid area are determined for grids buried in soils of low, moderate, and high resistivity, varying the grid dimension and considering the frequency dependence of soil parameters. Based on such results, expressions to obtain the impulse impedance from the low-frequency resistance are derived.

1 June 2018 in Electric Power Systems Research
Verified
Journal Article
Closed access
Marco Aurélio Oliveira SchroederMarco Aurélio Oliveira Schroeder
Marco Aurélio Oliveira Schroeder
MBMaria Teresa Correia de Barros
Maria Teresa Correia de Barros
ALAntonio C.S. Lima
Antonio C.S. Lima
MAMárcio M. Afonso
Márcio M. Afonso
Rodolfo Antônio Ribeiro de MouraRodolfo Antônio Ribeiro de Moura
Rodolfo Antônio Ribeiro de Moura

11 December 2017 in IEEE Transactions on Magnetics
Verified
Journal Article
Closed access
AFArthur A. M. Farah
Arthur A. M. Farah
MAMarcio M. Afonso
Marcio M. Afonso
JVJoao A. Vasconcelos
Joao A. Vasconcelos
Marco Aurélio Oliveira SchroederMarco Aurélio Oliveira Schroeder
Marco Aurélio Oliveira Schroeder
The purpose of this paper is to introduce a modified approach for the electric field computation at the surface of overhead transmission line (TL) conductors through the finite-element method (FEM). The proposed strategy is based on a spatial transformation, well-known as Kelvin transformation, resulting in a special way to treat the unbounded domain. Unlike other applications of the FEM in TLs, the suggested procedure aims to reduce the computational domain and the solution time, allowing an efficient numerical evaluation of the electric potential gradients, without the need of geometric simplifications of the conductors. Comparative results show that a more realistic treatment offers a better understanding of how electric fields operate near real conductors and, in addition, that the proposed approach can be used to provide an accurate design for conductor systems in TLs.

25 March 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Daniele MestrinerDaniele Mestriner
Daniele Mestriner
Rodolfo Antônio Ribeiro de MouraRodolfo Antônio Ribeiro de Moura
Rodolfo Antônio Ribeiro de Moura
Renato ProcopioRenato Procopio
Renato Procopio
Marco Aurélio Oliveira SchroederMarco Aurélio Oliveira Schroeder
Marco Aurélio Oliveira Schroeder
Lightning-induced voltages are one of the main causes of shutdown in distribution lines. In this work, attention is focused on the effects of wideband modeling of electric grounding in the overvoltage calculation along insulator strings due to indirect lightning strikes. This study is done directly in the time-domain with the grounding being represented with an equivalent circuit accounting for its dynamics. Results show that the adoption of commonly adopted simplified grounding models, such as low-frequency resistance, may lead to an underestimation of the overvoltage. According to the results, differences in the order of 25% can be found in some studied cases.

11 June 2022 in International Journal of Electrical Power & Energy Systems
Verified
Journal Article
Closed access
FCFabrício S.V. Campos
Fabrício S.V. Campos
FAFernando A. Assis
Fernando A. Assis
ASArmando M. Leite da Silva
Armando M. Leite da Silva
ACAlex J.C. Coelho
Alex J.C. Coelho
RMRodolfo A.R. Moura
Rodolfo A.R. Moura
Marco Aurélio Oliveira SchroederMarco Aurélio Oliveira Schroeder
Marco Aurélio Oliveira Schroeder