Lightning-induced voltages are one of the main causes of shutdown in distribution lines. In this work, attention is focused on the effects of wideband modeling of electric grounding in the overvoltage calculation along insulator strings due to indirect lightning strikes. This study is done directly in the time-domain with the grounding being represented with an equivalent circuit accounting for its dynamics. Results show that the adoption of commonly adopted simplified grounding models, such as low-frequency resistance, may lead to an underestimation of the overvoltage. According to the results, differences in the order of 25% can be found in some studied cases.
This paper presents a method for adjusting parameters of first stroke lightning currents, according to measured patterns of their waveforms for negative downward flashes. Waveforms are represented by a sum of Heidler functions, an approach previously adopted by other authors. As published in literature, in order to reproduce important characteristics of first stroke currents, such as the existence of a double peak, several Heidler functions are needed, and parameter fitting is a cumbersome task. The simplicity of the method presented here allows the direct adjustment of each parameter with low computational effort. Thus, this method is suitable for the generation of current waveforms to be applied in evaluating the lightning performance of overhead transmission lines according to a probabilistic-statistical approach.
1 January 2022 in International Journal of Electrical Power & Energy Systems
In most of the work that investigates the backflashover phenomenon due to direct lightning strikes, using EMT-type simulators, transmission lines are represented by the J. Marti model and the ground effect is computed employing J. R. Carson’s formulations. Thus, the ground displacement current is neglected, the line voltage definition corresponds to the wire potential formulation, and soil resistivity is considered frequency-independent. These considerations can lead to erroneous measurements of the occurrences of the backflashover phenomenon in the insulator strings of transmission line. In this sense, this paper presents a systematic sensitivity analysis study of lightning overvoltage in insulator strings considering more physically consistent models of the transmission line, which consider the displacement current, ground admittance correction, rigorous voltage definition, and frequency-dependent soil parameters. According to the results, for the case study, transmission line parameters modeling can present a maximum percentual difference of around 71.54%, considering the frequency range of first strokes. This difference leads to a percent difference of around 5.25% in the maximum overvoltage across the insulator strings. These differences confirm that the occurrence or not of backflashover in the insulator strings, including the disruption time, are sensitive to the line model considered.
1 November 2018 in Electric Power Systems Research