Piotr Rogala

Dr. Piotr Rogala


Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 October 2014 in Journal of Orthopaedic Surgery and Research
Verified
Journal Article
Open access
PDF file
LKLukasz Kubaszewski
Lukasz Kubaszewski
AZAnetta Zioła-Frankowska
Anetta Zioła-Frankowska
Marcin FrankowskiMarcin Frankowski
Marcin Frankowski
PRPiotr Rogala
Piotr Rogala
ZGZuzanna Gasik
Zuzanna Gasik
RGRobert Gasik
Robert Gasik
Trace element (TE) analysis in human tissue has the dual purpose of assessing environmental pollution and metabolism. In literature, bone TE analysis is common, but studies in intervertebral disc (IVD) tissue are lacking. The aim of the study was evaluation of the difference of TE concentration in intervertebral disc and bone in patients with degenerative changes. The comparison of the tissues differing in metabolism, blood perfusion, or separateness from adjoining tissues but playing similar biomechanical role and presenting some common morphological traits may shed new light on metabolism nuances, degenerative process, as well as accumulation potential of IVD in respect to bone. In the study, we analyzed two types of samples: intervertebral disc (n =30, from 22 patients operated due to degenerative disc disease) and femoral bone (n =26, separately femoral head and neck, from 26 patients, acquired in total hip arthroplasty procedure in course of idiopathic osteoarthritis of the hip joint). In the samples we analyzed, with atomic absorption spectrometry, the concentrations of Pb, Ni, Mo, Cu, Mg, and Zn. The element concentrations identified in bone are comparable to those presented in the literature. In the case of Pb, Ni, Mo, Mg, and Zn, the concentration in the bone was 2 to 25.8 times higher than that observed in the disc. Only the Cu concentration was higher in disc tissue than in bone. In disc tissue, fewer samples had TE concentrations below the detection threshold. We found significant differences in TE profiles in the compared tissues. The results show that the disc could serve as a more stable compartment for evaluating TE concentration, especially for TEs that are environmentally related.

29 June 2016 in Materials
Verified
Journal Article
Open access
PDF file
Ryszard UklejewskiRyszard Uklejewski
Ryszard Uklejewski
PRPiotr Rogala
Piotr Rogala
Mariusz WinieckiMariusz Winiecki
Mariusz Winiecki
RTRenata Tokłowicz
Renata Tokłowicz
Piotr RuszkowskiPiotr Ruszkowski
Piotr Ruszkowski
MWMaria Wolun-Cholewa
Maria Wolun-Cholewa
We present here—designed, manufactured, and tested by our research team—the Ti-alloy prototype of the multispiked connecting scaffold (MSC-Scaffold) interfacing the components of resurfacing arthroplasty (RA) endoprostheses with bone. The spikes of the MSC-Scaffold prototype mimic the interdigitations of the articular subchondral bone, which is the natural biostructure interfacing the articular cartilage with the periarticular trabecular bone. To enhance the osteoinduction/osteointegration potential of the MSC-Scaffold, the attempts to modify its bone contacting surfaces by the process of electrochemical cathodic deposition of Ca-P was performed with further immersion of the MSC-Scaffold prototypes in SBF in order to transform the amorphous calcium-phosphate coating in hydroxyapatite-like (HA-like) coating. The pilot experimental study of biointegration of unmodified and Ca-P surface-modified MSC-Scaffold prototypes was conducted in an animal model (swine) and in osteoblast cell culture. On the basis of a microscope-histological method the biointegration was proven by the presence of trabeculae in the interspike spaces of the MSC-Scaffold prototype on longitudinal and cross-sections of bone-implant specimens. The percentage of trabeculae in the area between the spikes of specimen containing Ca-P surface modified scaffold prototype observed in microCT reconstructions of the explanted joints was visibly higher than in the case of unmodified MSC-Scaffold prototypes. Significantly higher Alkaline Phosphatase (ALP) activity and the cellular proliferation in the case of Ca-P-modified MSC-Scaffold pre-prototypes, in comparison with unmodified pre-prototypes, was found in osteoblast cell cultures. The obtained results of experimental implantation in an animal model and osteoblast cell culture evaluations of Ca-P surface-modified and non-modified biomimetic MSC-Scaffold prototypes for biomimetic entirely-cementless RA endoprostheses indicate the enhancement of the osteoinduction/osteointegration potential by the Ca-P surface modification of the Ti-alloy MSC-Scaffold prototype. Planned further research on the prototype of this biomimetic MSC-Scaffold for a new generation of RA endoprostheses is also given.

12 March 2021 in Materials
Verified
Journal Article
Open access
PDF file
Ryszard UklejewskiRyszard Uklejewski
Ryszard Uklejewski
Mariusz WinieckiMariusz Winiecki
Mariusz Winiecki
Adam PatalasAdam Patalas
Adam Patalas
PRPiotr Rogala
Piotr Rogala
Our team has been working for some time on designing a new kind of biomimetic fixation of resurfacing endoprostheses, in which the innovative multi-spiked connecting scaffold (MSC-Scaffold) that mimics the natural interface between articular cartilage and periarticular trabecular bone in human joints is the crucial element. This work aimed to develop a numerical model enabling the design of the considered joint replacement implant that would reflect the mechanics of interacting biomaterials. Thus, quantitative micro-CT analysis of density distribution in bone material during the embedding of MSC-Scaffold in periarticular bone was applied. The performed numerical studies and corresponding mechanical tests revealed, under the embedded MSC-Scaffold, the bone material densification affecting its mechanical properties. On the basis of these findings, the built numerical model was modified by applying a simulated insert of densified bone material. This modification led to a strong correlation between the re-simulation and experimental results (FVU = 0.02). The biomimetism of the MSC-Scaffold prototype that provided physiological load transfer from implant to bone was confirmed based on the Huber–von Mises–Hencky (HMH) stress maps obtained with the validated finite element (FE) model of the problem. The micro-CT bone density assessment performed during the embedding of the MSC-Scaffold prototype in periarticular bone provides insight into the mechanical behaviour of the investigated implant-bone system and validates the numerical model that can be used for the design of material and geometric features of a new kind of resurfacing endoprostheses fixation.

8 February 2024 in Biomimetics
Verified
Journal Article
Open access
PDF file
Ryszard UklejewskiRyszard Uklejewski
Ryszard Uklejewski
Mariusz WinieckiMariusz Winiecki
Mariusz Winiecki
Mikolaj DabrowskiMikolaj Dabrowski
Mikolaj Dabrowski
PRPiotr Rogala
Piotr Rogala
This paper presents advances in designs of resurfacing arthroplasty endoprostheses that occurred through their historical generations. The critical characteristics of contemporary generation hip resurfacing arthroplasty endoprostheses are given and the failures resulting from the specific generation cemented and short stem fixation of the femoral component are reviewed. On the background of these failures, the critical need arises for an alternative approach to the fixation of components of resurfacing arthroplasty leading towards the first generation of biomimetic fixation for resurfacing arthroplasty endoprostheses. The state of the art of the completed bioengineering research on the first biomimetic fixation for resurfacing arthroplasty endoprostheses is presented. This new design type of completely cementless and stemless resurfacing arthroplasty endoprostheses of the hip joint (and other joints), where endoprosthesis components are embedded in the surrounding bone via the prototype biomimetic multi-spiked connecting scaffold (MSC-Scaffold), initiates the first at all generations of biomimetic endoprostheses of diarthrodial joints.

Verified
Journal Article
Open access
PDF file
Mikolaj DabrowskiMikolaj Dabrowski
Mikolaj Dabrowski
PRPiotr Rogala
Piotr Rogala
Ryszard UklejewskiRyszard Uklejewski
Ryszard Uklejewski
Adam PatalasAdam Patalas
Adam Patalas
Mariusz WinieckiMariusz Winiecki
Mariusz Winiecki
Bartosz GapińskiBartosz Gapiński
Bartosz Gapiński
The multi-spiked connecting scaffold (MSC-Scaffold) prototype is the essential innovation in the fixation of components of resurfacing total hip arthroplasty (THRA) endoprostheses in the subchondral trabecular bone. We conducted the computed micro-tomography (micro-CT) assessment of the subchondral trabecular bone microarchitecture before and after the MSC-Scaffold embedding in femoral heads removed during long-stem endoprosthesis total hip arthroplasty (THA) of different bone densities from 4 patients with hip osteoarthritis (OA). The embedding of the MSC-Scaffold in subchondral trabecular bone causes the change in its relative area (BA/TA, bone area/total area ratio) ranged from 18.2% to 24.7% (translating to the calculated density ρB relative change 11.1–14.4%, and the compressive strength S relative change 75.3–122.7%) regardless of its initial density (before the MSC-Scaffold embedding). The densification of the trabecular microarchitecture of subchondral trabecular bone due to the MSC-Scaffold initial embedding gradually decreases with the increasing distance from the apexes of the MSC-Scaffold’s spikes while the spatial extent of this subchondral trabecular bone densification ranged from 1.5 to 2.5 mm (which is about half the height of the MSC-Scaffold’s spikes). It may be suggested, despite the limited number of examined femoral heads, that: (1) the magnitude of the effect of the MSC-Scaffold embedding on subchondral trabecular bone densification may be a factor contributing to the maintenance of the MSC-Scaffold also for decreased initial bone density values, (2) the deeper this effect of the subchondral trabecular bone densification, the better strength of subchondral trabecular bone, and as consequence, the better post-operative embedding of the MSC-Scaffold in the bone should be expected.

9 January 2013
Verified
Journal Article
Closed access
WSWanda Stryła
Wanda Stryła
APAdam M Pogorzała
Adam M Pogorzała
PRPiotr Rogala
Piotr Rogala
ANAndrzej Nowakowski
Andrzej Nowakowski