Clint Bellenger

Dr. Clint Bellenger


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 February 2016 in Sports Medicine
Verified
Journal Article
Closed access
PDF file
CBClint Bellenger
Clint Bellenger
JFJoel Thomas Fuller
Joel Thomas Fuller
RTRebecca Thomson
Rebecca Thomson
KDKade Davison
Kade Davison
EREileen Y. Robertson
Eileen Y. Robertson
Jonathan BuckleyJonathan Buckley
Jonathan Buckley

26 July 2020 in Journal of Sports Sciences
Verified
Journal Article
Closed access
DMDean Miller
Dean Miller
Michele LastellaMichele Lastella
Michele Lastella
Aaron ScanlanAaron Scanlan
Aaron Scanlan
CBClint Bellenger
Clint Bellenger
SHShona Halson
Shona Halson
Charli SargentCharli Sargent
Charli Sargent
The aim of the study was to compare the WHOOP strap – a wearable device that estimates sleep based on measures of movement and heart rate derived from actigraphy and photoplethysmography, respectively. Twelve healthy adults (6 females, 6 males, aged 22.9 ± 3.4 years) participated in a 10-day, laboratory-based protocol. A total of 86 sleeps were independently assessed in 30-s epochs using polysomnography and WHOOP. For WHOOP, bed times were entered by researchers and sleeps were scored by the company based on proprietary algorithms. WHOOP overestimated total sleep time by 8.2 ± 32.9 minutes compared to polysomnography, but this difference was non-significant. WHOOP was compared to polysomnography for 2-stage (i.e., wake, sleep) and 4-stage categorisation (i.e., wake, light sleep [N1 or N2], slow-wave sleep [N3], REM) of sleep periods. For 2-stage categorisation, the agreement, sensitivity to sleep, specificity for wake, and Cohen’s kappa were 89%, 95%, 51%, and 0.49, respectively. For 4-stage categorisation, the agreement, sensitivity to light sleep, SWS, REM, and wake, and Cohen’s kappa were 64%, 62%, 68%, 70%, 51%, and 0.47, respectively. In situations where polysomnography is impractical (e.g., field settings), WHOOP is a reasonable method for estimating sleep, particularly for 2-stage categorisation, if accurate bedtimes are manually entered.

20 May 2021 in Sensors
Verified
Journal Article
Open access
PDF file
CBClint Bellenger
Clint Bellenger
DMDean Miller
Dean Miller
SHShona Halson
Shona Halson
GRGreg Roach
Greg Roach
Charli SargentCharli Sargent
Charli Sargent
Heart rate (HR) and HR variability (HRV) infer readiness to perform exercise in athletic populations. Technological advancements have facilitated HR and HRV quantification via photoplethysmography (PPG). This study evaluated the validity of WHOOP’s PPG-derived HR and HRV against electrocardiogram-derived (ECG) measures. HR and HRV were assessed via WHOOP 2.0 and ECG over 15 opportunities during October–December 2018. WHOOP-derived pulse-to-pulse (PP) intervals were edited with WHOOP’s proprietary filter, in addition to various filter strengths via Kubios HRV software. HR and HRV (Ln RMSSD) were quantified for each filter strength. Agreement was assessed via bias and limits of agreement (LOA), and contextualised using smallest worthwhile change (SWC) and coefficient of variation (CV). Regardless of filter strength, bias (≤0.39 ± 0.38%) and LOA (≤1.56%) in HR were lower than the CV (10–11%) and SWC (5–5.5%) for this parameter. For Ln RMSSD, bias (1.66 ± 1.80%) and LOA (±5.93%) were lowest for a 200 ms filter and WHOOP’s proprietary filter, which approached or exceeded the CV (3–13%) and SWC (1.5–6.5%) for this parameter. Acceptable agreement was found between WHOOP- and ECG-derived HR. Bias and LOA in Ln RMSSD approached or exceeded the SWC/CV for this variable and should be interpreted against its own level of bias precision.

14 February 2022 in Sports Medicine
Verified
Journal Article
Open access
PDF file
EMEmma Moore
Emma Moore
JFJoel Thomas Fuller
Joel Thomas Fuller
Jonathan BuckleyJonathan Buckley
Jonathan Buckley
SSSiena Saunders
Siena Saunders
SHShona Halson
Shona Halson
CBClint Bellenger
Clint Bellenger
Background: Studies investigating the effects of cold-water immersion (CWI) on the recovery of athletic performance, perceptual measures and creatine kinase (CK) have reported mixed results in physically active populations. Objectives: The purpose of this systematic review was to investigate the effects of CWI on recovery of athletic performance, perceptual measures and CK following an acute bout of exercise in physically active populations. Study Design: Systematic review with meta-analysis and meta-regression. Methods: A systematic search was conducted in September 2021 using Medline, SPORTDiscus, Scopus, Web of Science, Cochrane Library, EmCare and Embase databases. Studies were included if they were peer reviewed and published in English, included participants who were involved in sport or deemed physically active, compared CWI with passive recovery methods following an acute bout of strenuous exercise and included athletic performance, athlete perception and CK outcome measures. Studies were divided into two strenuous exercise subgroups: eccentric exercise and high-intensity exercise. Random effects meta-analyses were used to determine standardised mean differences (SMD) with 95% confidence intervals. Meta-regression analyses were completed with water temperature and exposure durations as continuous moderator variables. Results: Fifty-two studies were included in the meta-analyses. CWI improved the recovery of muscular power 24 h after eccentric exercise (SMD 0.34 [95% CI 0.06–0.62]) and after high-intensity exercise (SMD 0.22 [95% CI 0.004–0.43]), and reduced serum CK (SMD − 0.85 [95% CI − 1.61 to − 0.08]) 24 h after high-intensity exercise. CWI also improved muscle soreness (SMD − 0.89 [95% CI − 1.48 to − 0.29]) and perceived feelings of recovery (SMD 0.66 [95% CI 0.29–1.03]) 24 h after high-intensity exercise. There was no significant influence on the recovery of strength performance following either eccentric or high-intensity exercise. Meta-regression indicated that shorter time and lower temperatures were related to the largest beneficial effects on serum CK (duration and temperature dose effects) and endurance performance (duration dose effects only) after high-intensity exercise. Conclusion: CWI was an effective recovery tool after high-intensity exercise, with positive outcomes occurring for muscular power, muscle soreness, CK, and perceived recovery 24 h after exercise. However, after eccentric exercise, CWI was only effective for positively influencing muscular power 24 h after exercise. Dose–response relationships emerged for positively influencing endurance performance and reducing serum CK, indicating that shorter durations and lower temperatures may improve the efficacy of CWI if used after high-intensity exercise. Funding: Emma Moore is supported by a Research Training Program (Domestic) Scholarship from the Australian Commonwealth Department of Education and Training. Protocol registration: Open Science Framework: 10.17605/OSF.IO/SRB9D.


8 June 2021 in Biosensors
Verified
Journal Article
Open access
PDF file
DMDean Miller
Dean Miller
GRGreg Roach
Greg Roach
Michele LastellaMichele Lastella
Michele Lastella
Aaron ScanlanAaron Scanlan
Aaron Scanlan
CBClint Bellenger
Clint Bellenger
Charli SargentCharli Sargent
Charli Sargent
The aims of this study were to: (1) compare actigraphy (ACTICAL) and a commercially available sleep wearable (i.e., WHOOP) under two functionalities (i.e., sleep auto-detection (WHOOP-AUTO) and manual adjustment of sleep (WHOOP-MANUAL)) for two-stage categorisation of sleep (sleep or wake) against polysomnography, and; (2) compare WHOOP-AUTO and WHOOP-MANUAL for four-stage categorisation of sleep (wake, light sleep, slow wave sleep (SWS), or rapid eye movement sleep (REM)) against polysomnography. Six healthy adults (male: n = 3; female: n = 3; age: 23.0 ± 2.2 yr) participated in the nine-night protocol. Fifty-four sleeps assessed by ACTICAL, WHOOP-AUTO and WHOOP-MANUAL were compared to polysomnography using difference testing, Bland–Altman comparisons, and 30-s epoch-by-epoch comparisons. Compared to polysomnography, ACTICAL overestimated total sleep time (37.6 min) and underestimated wake (−37.6 min); WHOOP-AUTO underestimated SWS (−15.5 min); and WHOOP-MANUAL underestimated wake (−16.7 min). For ACTICAL, sensitivity for sleep, specificity for wake and overall agreement were 98%, 60% and 89%, respectively. For WHOOP-AUTO, sensitivity for sleep, wake, and agreement for two-stage and four-stage categorisation of sleep were 90%, 60%, 86% and 63%, respectively. For WHOOP-MANUAL, sensitivity for sleep, wake, and agreement for two-stage and four-stage categorisation of sleep were 97%, 45%, 90% and 62%, respectively. WHOOP-AUTO and WHOOP-MANUAL have a similar sensitivity and specificity to actigraphy for two-stage categorisation of sleep and can be used as a practical alternative to polysomnography for two-stage categorisation of sleep and four-stage categorisation of sleep.