Dean Miller

Mr. Dean Miller

CQUniversity Australia
orcid

Research Focus & Metrics

Academic Career Length

34Years (1993-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 August 2022 in Sensors
Verified
Journal Article
Open access
PDF file
DMDean Miller
Dean Miller
Charli SargentCharli Sargent
Charli Sargent
GRGreg Roach
Greg Roach
The primary aim of this study was to examine the validity of six commonly used wearable devices, i.e., Apple Watch S6, Garmin Forerunner 245 Music, Polar Vantage V, Oura Ring Generation 2, WHOOP 3.0 and Somfit, for assessing sleep. The secondary aim was to examine the validity of the six devices for assessing heart rate and heart rate variability during, or just prior to, night-time sleep. Fifty-three adults (26 F, 27 M, aged 25.4 ± 5.9 years) spent a single night in a sleep laboratory with 9 h in bed (23:00–08:00 h). Participants were fitted with all six wearable devices—and with polysomnography and electrocardiography for gold-standard assessment of sleep and heart rate, respectively. Compared with polysomnography, agreement (and Cohen’s kappa) for two-state categorisation of sleep periods (as sleep or wake) was 88% (κ = 0.30) for Apple Watch; 89% (κ = 0.35) for Garmin; 87% (κ = 0.44) for Polar; 89% (κ = 0.51) for Oura; 86% (κ = 0.44) for WHOOP and 87% (κ = 0.48) for Somfit. Compared with polysomnography, agreement (and Cohen’s kappa) for multi-state categorisation of sleep periods (as a specific sleep stage or wake) was 53% (κ = 0.20) for Apple Watch; 50% (κ = 0.25) for Garmin; 51% (κ = 0.28) for Polar; 61% (κ = 0.43) for Oura; 60% (κ = 0.44) for WHOOP and 65% (κ = 0.52) for Somfit. Analyses regarding the two-state categorisation of sleep indicate that all six devices are valid for the field-based assessment of the timing and duration of sleep. However, analyses regarding the multi-state categorisation of sleep indicate that all six devices require improvement for the assessment of specific sleep stages. As the use of wearable devices that are valid for the assessment of sleep increases in the general community, so too does the potential to answer research questions that were previously impractical or impossible to address—in some way, we could consider that the whole world is becoming a sleep laboratory.

10 December 2020 in PLOS ONE
Verified
Journal Article
Open access
PDF file
DMDean Miller
Dean Miller
JCJohn V. Capodilupo
John V. Capodilupo
Michele LastellaMichele Lastella
Michele Lastella
CSCharli Sargent
Charli Sargent
GRGregory D. Roach
Gregory D. Roach
ECEmily R. Capodilupo
Emily R. Capodilupo
COVID-19, the disease caused by the SARS-CoV-2 virus, can cause shortness of breath, lung damage, and impaired respiratory function. Containing the virus has proven difficult, in large part due to its high transmissibility during the pre-symptomatic incubation. The study’s aim was to determine if changes in respiratory rate could serve as a leading indicator of SARS-CoV-2 infections. A total of 271 individuals (age = 37.3 ± 9.5, 190 male, 81 female) who experienced symptoms consistent with COVID-19 were included– 81 tested positive for SARS-CoV-2 and 190 tested negative; these 271 individuals collectively contributed 2672 samples (days) of data (1856 healthy days, 231 while infected with COVID-19 and 585 while negative for COVID-19 but experiencing symptoms). To train a novel algorithm, individuals were segmented as follows; (1) a training dataset of individuals who tested positive for COVID-19 (n = 57 people, 537 samples); (2) a validation dataset of individuals who tested positive for COVID-19 (n = 24 people, 320 samples); (3) a validation dataset of individuals who tested negative for COVID-19 (n = 190 people, 1815 samples). All data was extracted from the WHOOP system, which uses data from a wrist-worn strap to produce validated estimates of respiratory rate and other physiological measures. Using the training dataset, a model was developed to estimate the probability of SARS-CoV-2 infection based on changes in respiratory rate during night-time sleep. The model’s ability to identify COVID-positive individuals not used in training and robustness against COVID-negative individuals with similar symptoms were examined for a critical six-day period spanning the onset of symptoms. The model identified 20% of COVID-19 positive individuals in the validation dataset in the two days prior to symptom onset, and 80% of COVID-19 positive cases by the third day of symptoms.

21 May 2007 in Physical Review B
Verified
Journal Article
Open access
PDF file
Raul ArenalRaul Arenal
Raul Arenal
PBP. Bruno
P. Bruno
DMDean Miller
Dean Miller
MBM. Bleuel
M. Bleuel
JLJ. Lal
J. Lal
DGD. M. Gruen
D. M. Gruen
Further progress in the development of the remarkable electrochemical, electron field emission, high-temperature diode, and optical properties of n-type ultrananocrystalline diamond films requires a better understanding of electron transport in this material. Of particular interest is the origin of the transition to the metallic regime observed when about 10% by volume of nitrogen has been added to the synthesis gas. Here, we present data showing that the transition to the metallic state is due to the formation of partially oriented diamond nanowires surrounded by an sp2-bonded carbon sheath. These have been characterized by scanning electron microscopy, transmission electron microscopy techniques (high-resolution mode, selected area electron diffraction, and electron-energy-loss spectroscopy), Raman spectroscopy, and small-angle neutron scattering. The nanowires are 80–100nm in length and consist of ∼5nm wide and 6–10nm long segments of diamond crystallites exhibiting atomically sharp interfaces. Each nanowire is enveloped in a sheath of sp2-bonded carbon that provides the conductive path for electrons. Raman spectroscopy on the films coupled with a consideration of plasma chemical and physical processes reveals that the sheath is likely composed of a nanocarbon material resembling in some respects a polymer-like mixture of polyacetylene and polynitrile. The complex interactions governing the simultaneous growth of the diamond core and the sp2 sheath responsible for electrical conductivity are discussed as are attempts at a better theoretical understanding of the transport mechanism.

26 July 2020 in Journal of Sports Sciences
Verified
Journal Article
Closed access
DMDean Miller
Dean Miller
Michele LastellaMichele Lastella
Michele Lastella
Aaron ScanlanAaron Scanlan
Aaron Scanlan
CBClint Bellenger
Clint Bellenger
SHShona Halson
Shona Halson
Charli SargentCharli Sargent
Charli Sargent
The aim of the study was to compare the WHOOP strap – a wearable device that estimates sleep based on measures of movement and heart rate derived from actigraphy and photoplethysmography, respectively. Twelve healthy adults (6 females, 6 males, aged 22.9 ± 3.4 years) participated in a 10-day, laboratory-based protocol. A total of 86 sleeps were independently assessed in 30-s epochs using polysomnography and WHOOP. For WHOOP, bed times were entered by researchers and sleeps were scored by the company based on proprietary algorithms. WHOOP overestimated total sleep time by 8.2 ± 32.9 minutes compared to polysomnography, but this difference was non-significant. WHOOP was compared to polysomnography for 2-stage (i.e., wake, sleep) and 4-stage categorisation (i.e., wake, light sleep [N1 or N2], slow-wave sleep [N3], REM) of sleep periods. For 2-stage categorisation, the agreement, sensitivity to sleep, specificity for wake, and Cohen’s kappa were 89%, 95%, 51%, and 0.49, respectively. For 4-stage categorisation, the agreement, sensitivity to light sleep, SWS, REM, and wake, and Cohen’s kappa were 64%, 62%, 68%, 70%, 51%, and 0.47, respectively. In situations where polysomnography is impractical (e.g., field settings), WHOOP is a reasonable method for estimating sleep, particularly for 2-stage categorisation, if accurate bedtimes are manually entered.

20 May 2021 in Sensors
Verified
Journal Article
Open access
PDF file
CBClint Bellenger
Clint Bellenger
DMDean Miller
Dean Miller
SHShona Halson
Shona Halson
GRGreg Roach
Greg Roach
Charli SargentCharli Sargent
Charli Sargent
Heart rate (HR) and HR variability (HRV) infer readiness to perform exercise in athletic populations. Technological advancements have facilitated HR and HRV quantification via photoplethysmography (PPG). This study evaluated the validity of WHOOP’s PPG-derived HR and HRV against electrocardiogram-derived (ECG) measures. HR and HRV were assessed via WHOOP 2.0 and ECG over 15 opportunities during October–December 2018. WHOOP-derived pulse-to-pulse (PP) intervals were edited with WHOOP’s proprietary filter, in addition to various filter strengths via Kubios HRV software. HR and HRV (Ln RMSSD) were quantified for each filter strength. Agreement was assessed via bias and limits of agreement (LOA), and contextualised using smallest worthwhile change (SWC) and coefficient of variation (CV). Regardless of filter strength, bias (≤0.39 ± 0.38%) and LOA (≤1.56%) in HR were lower than the CV (10–11%) and SWC (5–5.5%) for this parameter. For Ln RMSSD, bias (1.66 ± 1.80%) and LOA (±5.93%) were lowest for a 200 ms filter and WHOOP’s proprietary filter, which approached or exceeded the CV (3–13%) and SWC (1.5–6.5%) for this parameter. Acceptable agreement was found between WHOOP- and ECG-derived HR. Bias and LOA in Ln RMSSD approached or exceeded the SWC/CV for this variable and should be interpreted against its own level of bias precision.

8 June 2021 in Biosensors
Verified
Journal Article
Open access
PDF file
DMDean Miller
Dean Miller
GRGreg Roach
Greg Roach
Michele LastellaMichele Lastella
Michele Lastella
Aaron ScanlanAaron Scanlan
Aaron Scanlan
CBClint Bellenger
Clint Bellenger
Charli SargentCharli Sargent
Charli Sargent
The aims of this study were to: (1) compare actigraphy (ACTICAL) and a commercially available sleep wearable (i.e., WHOOP) under two functionalities (i.e., sleep auto-detection (WHOOP-AUTO) and manual adjustment of sleep (WHOOP-MANUAL)) for two-stage categorisation of sleep (sleep or wake) against polysomnography, and; (2) compare WHOOP-AUTO and WHOOP-MANUAL for four-stage categorisation of sleep (wake, light sleep, slow wave sleep (SWS), or rapid eye movement sleep (REM)) against polysomnography. Six healthy adults (male: n = 3; female: n = 3; age: 23.0 ± 2.2 yr) participated in the nine-night protocol. Fifty-four sleeps assessed by ACTICAL, WHOOP-AUTO and WHOOP-MANUAL were compared to polysomnography using difference testing, Bland–Altman comparisons, and 30-s epoch-by-epoch comparisons. Compared to polysomnography, ACTICAL overestimated total sleep time (37.6 min) and underestimated wake (−37.6 min); WHOOP-AUTO underestimated SWS (−15.5 min); and WHOOP-MANUAL underestimated wake (−16.7 min). For ACTICAL, sensitivity for sleep, specificity for wake and overall agreement were 98%, 60% and 89%, respectively. For WHOOP-AUTO, sensitivity for sleep, wake, and agreement for two-stage and four-stage categorisation of sleep were 90%, 60%, 86% and 63%, respectively. For WHOOP-MANUAL, sensitivity for sleep, wake, and agreement for two-stage and four-stage categorisation of sleep were 97%, 45%, 90% and 62%, respectively. WHOOP-AUTO and WHOOP-MANUAL have a similar sensitivity and specificity to actigraphy for two-stage categorisation of sleep and can be used as a practical alternative to polysomnography for two-stage categorisation of sleep and four-stage categorisation of sleep.