Jordi Alastruey

Dr. Jordi Alastruey

orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2007 in Journal of Biomechanics
Verified
Journal Article
Closed access
JAJordi Alastruey
Jordi Alastruey
KPK.H. Parker
K.H. Parker
JPJ. Peiró
J. Peiró
SBS.M. Byrd
S.M. Byrd
SSSpencer Sherwin
Spencer Sherwin

24 October 2017 in IEEE Reviews in Biomedical Engineering
Verified
Journal Article
Open access
Peter CharltonPeter Charlton
Peter Charlton
DBDrew A. Birrenkott
Drew A. Birrenkott
TBTimothy Bonnici
Timothy Bonnici
MPMarco A. F. Pimentel
Marco A. F. Pimentel
AJAlistair E. W. Johnson
Alistair E. W. Johnson
DCDavid Clifton
David Clifton
Breathing rate (BR) is a key physiological parameter used in a range of clinical settings. Despite its diagnostic and prognostic value, it is still widely measured by counting breaths manually. A plethora of algorithms have been proposed to estimate BR from the electrocardiogram (ECG) and pulse oximetry (photoplethysmogram, PPG) signals. These BR algorithms provide opportunity for automated, electronic, and unobtrusive measurement of BR in both healthcare and fitness monitoring. This paper presents a review of the literature on BR estimation from the ECG and PPG. First, the structure of BR algorithms and the mathematical techniques used at each stage are described. Second, the experimental methodologies that have been used to assess the performance of BR algorithms are reviewed, and a methodological framework for the assessment of BR algorithms is presented. Third, we outline the most pressing directions for future research, including the steps required to use BR algorithms in wearable sensors, remote video monitoring, and clinical practice.

24 September 2013 in International Journal for Numerical Methods in Biomedical Engineering
Verified
Journal Article
Open access
PDF file
NXNan Xiao
Nan Xiao
JAJordi Alastruey
Jordi Alastruey
C. Alberto FigueroaC. Alberto Figueroa
C. Alberto Figueroa
SUMMARY: We present a systematic comparison of computational hemodynamics in arteries between a one‐dimensional (1‐D) and a three‐dimensional (3‐D) formulation with deformable vessel walls. The simulations were performed using a series of idealized compliant arterial models representing the common carotid artery, thoracic aorta, aortic bifurcation, and full aorta from the arch to the iliac bifurcation. The formulations share identical inflow and outflow boundary conditions and have compatible material laws. We also present an iterative algorithm to select the parameters for the outflow boundary conditions by using the 1‐D theory to achieve a desired systolic and diastolic pressure at a particular vessel. This 1‐D/3‐D framework can be used to efficiently determine material and boundary condition parameters for 3‐D subject‐specific arterial models with deformable vessel walls. Finally, we explore the impact of different anatomical features and hemodynamic conditions on the numerical predictions. The results show good agreement between the two formulations, especially during the diastolic phase of the cycle. © 2013 The Authors. International Journal for Numerical Methods in Biomedical Engineering published by John Wiley & Sons, Ltd.

1 August 2011 in Journal of Biomechanics
Verified
Journal Article
Open access
JAJordi Alastruey
Jordi Alastruey
AKAshraf William Khir
Ashraf William Khir
KMKoen S. Matthys
Koen S. Matthys
PSPatrick Segers
Patrick Segers
SSSpencer Sherwin
Spencer Sherwin
JPJoaquim Peiró
Joaquim Peiró
The accuracy of the nonlinear one-dimensional (1-D) equations of pressure and flow wave propagation in Voigt-type visco-elastic arteries was tested against measurements in a well-defined experimental 1:1 replica of the 37 largest conduit arteries in the human systemic circulation. The parameters required by the numerical algorithm were directly measured in the in vitro setup and no data fitting was involved. The inclusion of wall visco-elasticity in the numerical model reduced the underdamped high-frequency oscillations obtained using a purely elastic tube law, especially in peripheral vessels, which was previously reported in this paper [Matthys et al., 2007. Pulse wave propagation in a model human arterial network: Assessment of 1-D numerical simulations against in vitro measurements. J. Biomech. 40, 3476-3486]. In comparison to the purely elastic model, visco-elasticity significantly reduced the average relative root-mean-square errors between numerical and experimental waveforms over the 70 locations measured in the in vitro model: from 3.0% to 2.5% (p<0.012) for pressure and from 15.7% to 10.8% (p<0.002) for the flow rate. In the frequency domain, average relative errors between numerical and experimental amplitudes from the 5th to the 20th harmonic decreased from 0.7% to 0.5% (p<0.107) for pressure and from 7.0% to 3.3% (p<10(-6)) for the flow rate. These results provide additional support for the use of 1-D reduced modelling to accurately simulate clinically relevant problems at a reasonable computational cost.

11 March 2022 in Proceedings of the IEEE
Verified
Journal Article
Open access
Peter CharltonPeter Charlton
Peter Charlton
Panicos KyriacouPanicos Kyriacou
Panicos Kyriacou
JMJonathan Mant
Jonathan Mant
VMVaidotas Marozas
Vaidotas Marozas
PCPhil Chowienczyk
Phil Chowienczyk
JAJordi Alastruey
Jordi Alastruey
Smart wearables provide an opportunity to monitor health in daily life and are emerging as potential tools for detecting cardiovascular disease (CVD). Wearables such as fitness bands and smartwatches routinely monitor the photoplethysmogram signal, an optical measure of the arterial pulse wave that is strongly influenced by the heart and blood vessels. In this survey, we summarize the fundamentals of wearable photoplethysmography and its analysis, identify its potential clinical applications, and outline pressing directions for future research in order to realize its full potential for tackling CVD.

1 January 2007 in Journal of Biomechanics
Verified
Journal Article
Open access
KMKoen S. Matthys
Koen S. Matthys
JAJordi Alastruey
Jordi Alastruey
JPJoaquim Peiró
Joaquim Peiró
AKAshraf William Khir
Ashraf William Khir
PSPatrick Segers
Patrick Segers
SSSpencer Sherwin
Spencer Sherwin
A numerical model based on the nonlinear, one-dimensional (1-D) equations of pressure and flow wave propagation in conduit arteries is tested against a well-defined experimental 1:1 replica of the human arterial tree. The tree consists of 37 silicone branches representing the largest central systemic arteries in the human, including the aorta, carotid arteries and arteries that perfuse the upper and lower limbs and the main abdominal organs. The set-up is mounted horizontally and connected to a pulsatile pump delivering a periodic output similar to the aortic flow. Terminal branches end in simple resistance models, consisting of stiff capillary tubes leading to an overflow reservoir that reflects a constant venous pressure. The parameters required by the numerical algorithm are directly measured in the in vitro set-up and no data fitting is involved. Comparison of experimental and numerical pressure and flow waveforms shows the ability of the 1-D time-domain formulation to capture the main features of pulse wave propagation measured throughout the system test. As a consequence of the simple resistive boundary conditions used to reduce the uncertainty of the parameters involved in the simulation, the experimental set-up generates waveforms at terminal branches with additional non-physiological oscillations. The frequencies of these oscillations are well captured by the 1-D model, even though amplitudes are overestimated. Adding energy losses in bifurcations and including fluid inertia and compliance to the purely resistive terminal models does not reduce the underdamped effect, suggesting that wall visco-elasticity might play an important role in the experimental results. Nevertheless, average relative root-mean-square errors between simulations and experimental waveforms are smaller than 4% for pressure and 19% for the flow at all 70 locations studied.