Peter Charlton

Dr. Peter Charlton

Department of Public Health and Primary Care, University of Cambridge
+1

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 November 2016 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Open access
MPMarco A. F. Pimentel
Marco A. F. Pimentel
AJAlistair E. W. Johnson
Alistair E. W. Johnson
Peter CharltonPeter Charlton
Peter Charlton
DBDrew Birrenkott
Drew Birrenkott
PWPeter J. Watkinson
Peter J. Watkinson
DCDavid A. Clifton
David A. Clifton
Goal: Current methods for estimating respiratory rate (RR) from the photoplethysmogram (PPG) typically fail to distinguish between periods of high- and low-quality input data, and fail to perform well on independent “validation” datasets. The lack of robustness of existing methods directly results in a lack of penetration of such systems into clinical practice. The present work proposes an alternative method to improve the robustness of the estimation of RR from the PPG. Methods: The proposed algorithm is based on the use of multiple autoregressive models of different orders for determining the dominant respiratory frequency in the three respiratory-induced variations (frequency, amplitude, and intensity) derived from the PPG. The algorithm was tested on two different datasets comprising 95 eight-minute PPG recordings (in total) acquired from both children and adults in different clinical settings, and its performance using two window sizes (32 and 64 seconds) was compared with that of existing methods in the literature. Results: The proposed method achieved comparable accuracy to existing methods in the literature, with mean absolute errors (median, 25th-75th percentiles for a window size of 32 seconds) of 1.5 (0.3-3.3) and 4.0 (1.8-5.5) breaths per minute (for each dataset respectively), whilst providing RR estimates for a greater proportion of windows (over 90% of the input data are kept). Conclusion: Increased robustness of RR estimation by the proposed method was demonstrated. Significance: This work demonstrates that the use of large publicly available datasets is essential for improving the robustness of wearable-monitoring algorithms for use in clinical practice.

24 October 2017 in IEEE Reviews in Biomedical Engineering
Verified
Journal Article
Open access
Peter CharltonPeter Charlton
Peter Charlton
DBDrew A. Birrenkott
Drew A. Birrenkott
TBTimothy Bonnici
Timothy Bonnici
MPMarco A. F. Pimentel
Marco A. F. Pimentel
AJAlistair E. W. Johnson
Alistair E. W. Johnson
DCDavid Clifton
David Clifton
Breathing rate (BR) is a key physiological parameter used in a range of clinical settings. Despite its diagnostic and prognostic value, it is still widely measured by counting breaths manually. A plethora of algorithms have been proposed to estimate BR from the electrocardiogram (ECG) and pulse oximetry (photoplethysmogram, PPG) signals. These BR algorithms provide opportunity for automated, electronic, and unobtrusive measurement of BR in both healthcare and fitness monitoring. This paper presents a review of the literature on BR estimation from the ECG and PPG. First, the structure of BR algorithms and the mathematical techniques used at each stage are described. Second, the experimental methodologies that have been used to assess the performance of BR algorithms are reviewed, and a methodological framework for the assessment of BR algorithms is presented. Third, we outline the most pressing directions for future research, including the steps required to use BR algorithms in wearable sensors, remote video monitoring, and clinical practice.

30 March 2016 in Physiological Measurement
Verified
Journal Article
Open access
PDF file
Peter CharltonPeter Charlton
Peter Charlton
TBTimothy Bonnici
Timothy Bonnici
LTLionel Tarassenko
Lionel Tarassenko
DCDavid A Clifton
David A Clifton
RBRichard Beale
Richard Beale
PWPeter J Watkinson
Peter J Watkinson
Over 100 algorithms have been proposed to estimate respiratory rate (RR) from the electrocardiogram (ECG) and photoplethysmogram (PPG). As they have never been compared systematically it is unclear which algorithm performs the best. Our primary aim was to determine how closely algorithms agreed with a gold standard RR measure when operating under ideal conditions. Secondary aims were: (i) to compare algorithm performance with IP, the clinical standard for continuous respiratory rate measurement in spontaneously breathing patients; (ii) to compare algorithm performance when using ECG and PPG; and (iii) to provide a toolbox of algorithms and data to allow future researchers to conduct reproducible comparisons of algorithms. Algorithms were divided into three stages: extraction of respiratory signals, estimation of RR, and fusion of estimates. Several interchangeable techniques were implemented for each stage. Algorithms were assembled using all possible combinations of techniques, many of which were novel. After verification on simulated data, algorithms were tested on data from healthy participants. RRs derived from ECG, PPG and IP were compared to reference RRs obtained using a nasal-oral pressure sensor using the limits of agreement (LOA) technique. 314 algorithms were assessed. Of these, 270 could operate on either ECG or PPG, and 44 on only ECG. The best algorithm had 95% LOAs of -4.7 to 4.7 bpm and a bias of 0.0 bpm when using the ECG, and -5.1 to 7.2 bpm and 1.0 bpm when using PPG. IP had 95% LOAs of -5.6 to 5.2 bpm and a bias of -0.2 bpm. Four algorithms operating on ECG performed better than IP. All high-performing algorithms consisted of novel combinations of time domain RR estimation and modulation fusion techniques. Algorithms performed better when using ECG than PPG. The toolbox of algorithms and data used in this study are publicly available.

23 July 2014 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Open access
COChristina Orphanidou
Christina Orphanidou
TBTimothy Bonnici
Timothy Bonnici
Peter CharltonPeter Charlton
Peter Charlton
DCDavid Clifton
David Clifton
DVDavid Vallance
David Vallance
LTLionel Tarassenko
Lionel Tarassenko
The identification of invalid data in recordings obtained using wearable sensors is of particular importance since data obtained from mobile patients is, in general, noisier than data obtained from nonmobile patients. In this paper, we present a signal quality index (SQI), which is intended to assess whether reliable heart rates (HRs) can be obtained from electrocardiogram (ECG) and photoplethysmogram (PPG) signals collected using wearable sensors. The algorithms were validated on manually labeled data. Sensitivities and specificities of 94% and 97% were achieved for the ECG and 91% and 95% for the PPG. Additionally, we propose two applications of the SQI. First, we demonstrate that, by using the SQI as a trigger for a power-saving strategy, it is possible to reduce the recording time by up to 94% for the ECG and 93% for the PPG with only minimal loss of valid vital-sign data. Second, we demonstrate how an SQI can be used to reduce the error in the estimation of respiratory rate (RR) from the PPG. The performance of the two applications was assessed on data collected from a clinical study on hospital patients who were able to walk unassisted.

11 March 2022 in Proceedings of the IEEE
Verified
Journal Article
Open access
Peter CharltonPeter Charlton
Peter Charlton
Panicos KyriacouPanicos Kyriacou
Panicos Kyriacou
JMJonathan Mant
Jonathan Mant
VMVaidotas Marozas
Vaidotas Marozas
PCPhil Chowienczyk
Phil Chowienczyk
JAJordi Alastruey
Jordi Alastruey
Smart wearables provide an opportunity to monitor health in daily life and are emerging as potential tools for detecting cardiovascular disease (CVD). Wearables such as fitness bands and smartwatches routinely monitor the photoplethysmogram signal, an optical measure of the arterial pulse wave that is strongly influenced by the heart and blood vessels. In this survey, we summarize the fundamentals of wearable photoplethysmography and its analysis, identify its potential clinical applications, and outline pressing directions for future research in order to realize its full potential for tackling CVD.

1 November 2019 in American Journal of Physiology-Heart and Circulatory Physiology
Verified
Journal Article
Closed access
PDF file
Peter CharltonPeter Charlton
Peter Charlton
JHJorge Mariscal Harana
Jorge Mariscal Harana
SVSamuel Vennin
Samuel Vennin
YLYe Li
Ye Li
PCPhil Chowienczyk
Phil Chowienczyk
JAJordi Alastruey
Jordi Alastruey
The arterial pulse wave (PW) is a rich source of information on cardiovascular (CV) health. It is widely measured by both consumer and clinical devices. However, the physical determinants of the PW are not yet fully understood, and the development of PW analysis algorithms is limited by a lack of PW datasets containing reference CV measurements. Our aim was to create a database of PWs simulated by a computer to span a range of CV conditions, representative of a sample of healthy adults. The typical CV properties of 25-75 year olds were identified through a literature review. These were used as inputs to a computational model to simulate PWs for subjects of each age decade. Pressure, flow velocity, luminal area and photoplethysmographic (PPG) PWs were simulated at common measurement sites, and PW indices were extracted. The database, containing PWs from 4,374 virtual subjects, was verified by comparing the simulated PWs and derived indices with corresponding in vivo data. Good agreement was observed, with well-reproduced age-related changes in haemodynamic parameters and PW morphology. The utility of the database was demonstrated through case studies providing novel haemodynamic insights, in silico assessment of PW algorithms, and pilot data to inform the design of clinical PW algorithm assessments. In conclusion, the publicly available PW database (DOI: 10.5281/zenodo.2633175) is a valuable resource for understanding CV determinants of PWs, and for the development and pre-clinical assessment of PW analysis algorithms. It is particularly useful because the exact CV properties which generated each PW are known.