Weiwei Jin

Dr. Weiwei Jin

orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 June 2021 in PLOS ONE
Verified
Journal Article
Open access
PDF file
WJWeiwei Jin
Weiwei Jin
PCPhilip Chowienczyk
Philip Chowienczyk
JAJordi Alastruey
Jordi Alastruey
One of the European gold standard measurement of vascular ageing, a risk factor for cardiovascular disease, is the carotid-femoral pulse wave velocity (cfPWV), which requires an experienced operator to measure pulse waves at two sites. In this work, two machine learning pipelines were proposed to estimate cfPWV from the peripheral pulse wave measured at a single site, the radial pressure wave measured by applanation tonometry. The study populations were the Twins UK cohort containing 3,082 subjects aged from 18 to 110 years, and a database containing 4,374 virtual subjects aged from 25 to 75 years. The first pipeline uses Gaussian process regression to estimate cfPWV from features extracted from the radial pressure wave using pulse wave analysis. The mean difference and upper and lower limits of agreement (LOA) of the estimation on the 924 hold-out test subjects from the Twins UK cohort were 0.2 m/s, and 3.75 m/s & -3.34 m/s, respectively. The second pipeline uses a recurrent neural network (RNN) to estimate cfPWV from the entire radial pressure wave. The mean difference and upper and lower LOA of the estimation on the 924 hold-out test subjects from the Twins UK cohort were 0.05 m/s, and 3.21 m/s & -3.11m/s, respectively. The percentage error of the RNN estimates on the virtual subjects increased by less than 2% when adding 20% of random noise to the pressure waveform. These results show the possibility of assessing the vascular ageing using a single peripheral pulse wave (e.g. the radial pressure wave), instead of cfPWV. The proposed code for the machine learning pipelines is available from the following online depository (https://github.com/WeiweiJin/Estimate-Cardiovascular-Risk-from-Pulse-Wave-Signal).

14 April 2021 in Journal of The Royal Society Interface
Verified
Journal Article
Open access
WJWeiwei Jin
Weiwei Jin
JAJordi Alastruey
Jordi Alastruey
One-dimensional (1-D) arterial blood flow modelling was tested in a series of idealized vascular geometries representing the abdominal aorta, common carotid and iliac arteries with different sizes of stenoses and/or aneurysms. Three-dimensional (3-D) modelling andin vitromeasurements were used as ground truth to assess the accuracy of 1-D model pressure and flow waves. The 1-D and 3-D formulations shared identical boundary conditions and had equivalent vascular geometries and material properties. The parameters of an experimental set-up of the abdominal aorta for different aneurysm sizes were matched in corresponding 1-D models. Results show the ability of 1-D modelling to capture the main features of pressure and flow waves, pressure drop across the stenoses and energy dissipation across aneurysms observed in the 3-D and experimental models. Under physiological Reynolds numbers (Re), root mean square errors were smaller than 5.4% for pressure and 7.3% for the flow, for stenosis and aneurysm sizes of up to 85% and 400%, respectively. Relative errors increased with the increasing stenosis and aneurysm size, aneurysm length andRe, and decreasing stenosis length. All data generated in this study are freely available and provide a valuable resource for future research.

5 May 2021 in Symmetry
Verified
Journal Article
Open access
PDF file
TWTianqi Wang
Tianqi Wang
WJWeiwei Jin
Weiwei Jin
FLFuyou Liang
Fuyou Liang
JAJordi Alastruey
Jordi Alastruey
An abdominal aortic aneurysm (AAA) is usually asymptomatic until rupture, which is associated with extremely high mortality. Consequently, the early detection of AAAs is of paramount importance in reducing mortality; however, most AAAs are detected by medical imaging only incidentally. The aim of this study was to investigate the feasibility of machine learning-based pulse wave (PW) analysis for the early detection of AAAs using a database of in silico PWs. PWs in the large systemic arteries were simulated using one-dimensional blood flow modelling. A database of in silico PWs representative of subjects (aged 55, 65 and 75 years) with different AAA sizes was created by varying the AAA-related parameters with major impacts on PWs—identified by parameter sensitivity analysis—in an existing database of in silico PWs representative of subjects without AAAs. Then, a machine learning architecture for AAA detection was trained and tested using the new in silico PW database. The parameter sensitivity analysis revealed that the AAA maximum diameter and stiffness of the large systemic arteries were the dominant AAA-related biophysical properties considerably influencing the PWs. However, AAA detection by PW indexes was compromised by other non-AAA related cardiovascular parameters. The proposed machine learning model produced a sensitivity of 86.8 % and a specificity of 86.3 % in early detection of AAA from the photoplethysmogram PW signal measured in the digital artery with added random noise. The number of false positive and negative results increased with increasing age and decreasing AAA size, respectively. These findings suggest that machine learning-based PW analysis is a promising approach for AAA screening using PW signals acquired by wearable devices.

17 April 2020 in American Journal of Physiology-Heart and Circulatory Physiology
Verified
Journal Article
Closed access
PDF file
WJWeiwei Jin
Weiwei Jin
PCPhilip Chowienczyk
Philip Chowienczyk
JAJordi Alastruey
Jordi Alastruey
First, a novel computational model simulating arterial hemodynamics during flow-mediated dilation (FMD) was proposed. Second, the model was used to explain why FMD may be influenced by endothelium-independent factors, showing that FMD results are 1) partly masked by the vasoconstriction due to the change in transmural pressure and 2) affected by physiological factors (i.e., arterial stiffness and arterial blood pressure) that are difficult to eliminate due to their multiple interactions.

30 November 2020 in medRxiv
Verified
Preprint
Open access
PDF file
WJWeiwei Jin
Weiwei Jin
PCPhilip Chowienczyk
Philip Chowienczyk
JAJordi Alastruey
Jordi Alastruey
One of the European gold standard measurement of vascular ageing, a risk factor for cardiovascular disease, is the carotid-femoral pulse wave velocity (cfPWV), which requires an experienced operator to measure pulse waves at two sites. In this work, two machine learning pipelines were proposed to estimate cfPWV from the peripheral pulse wave measured at a single site, the radial pressure wave measured by applanation tonometry. The study populations were the Twins UK cohort containing 3,082 subjects aged from 18 to 110 years, and a database containing 4,374 virtual subjects aged from 25 to 75 years. The first pipeline uses Gaussian process regression to estimate cfPWV from features extracted from the radial pressure wave using pulse wave analysis. The mean difference and upper and lower limits of agreement (LOA) of the estimation on the 924 hold-out test subjects from the Twins UK cohort were 0.2 m/s, and 3.75 m/s & −3.34 m/s, respectively. The second pipeline uses a recurrent neural network (RNN) to estimate cfPWV from the entire radial pressure wave. The mean difference and upper and lower LOA of the estimation on the 924 hold-out test subjects from the Twins UK cohort were 0.05 m/s, and 3.21 m/s & −3.11m/s, respectively. The percentage error of the RNN estimates on the virtual subjects increased by less than 2% when adding 20% of random noise to the pressure waveform. These results show the possibility of assessing the vascular ageing using a single peripheral pulse wave ( e.g . the radial pressure wave), instead of cfPWV. The proposed code for the machine learning pipelines is available from the following online depository ( https://github.com/WeiweiJin/Estimate-Cardiovascular-Risk-from-Pulse-Wave-Signal ).

6 January 2026 in Journal of the American Heart Association
Verified
Journal Article
Open access
DSDavid Shavelle
David Shavelle
DRDerek Rinderknecht
Derek Rinderknecht
WJWeiwei Jin
Weiwei Jin
WCWei-min Brian Chiu
Wei-min Brian Chiu
AKAsia Krupa
Asia Krupa
SBSteven Bailey
Steven Bailey
Background: Measurement of left ventricular end‐diastolic pressure (LVEDP) is an established diagnostic method to evaluate heart failure but requires an invasive procedure. A noninvasive technique for detecting elevated LVEDP would improve the diagnosis of heart failure. Herein, we present the results of a multicenter study to validate a noninvasive system to detect elevated LVEDP. Methods: The Vivio System includes a modified blood pressure cuff and single‐lead ECG to capture brachial artery waveforms. A model was created to identify patients with elevated LVEDP (>18 mm Hg). For the invasive cohort, all patients were referred for coronary angiography and left heart catheterization for clinical indications. A group of 321 patients with no significant health problems were enrolled as a control cohort. Invasive LVEDP measurements were performed using Millar catheters. The training data set (n=262) contained 101 patients with LVEDP measurements (n=44 with LVEDP >18 mm Hg) and 161 controls. The validation data set (n=155) contained 75 patients with LVEDP measurements (n=40 with LVEDP >18 mm Hg) and 80 controls. Results: Leave‐one‐out cross‐validation on the training data set yielded a sensitivity of 0.84 (95% CI, 0.70–0.93]) and a specificity of 0.84 (95% CI, 0.79–0.89). The validation data set showed a sensitivity of 0.80 (95% CI, 0.64–0.91) and a specificity of 0.83 (95% CI, 0.75–0.90). Conclusions: The Vivio System can accurately detect elevated LVEDP and has the potential to significantly improve early detection of heart failure in the outpatient setting.