Tianqi Wang

Mr. Tianqi Wang

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 May 2021 in Symmetry
Verified
Journal Article
Open access
PDF file
TWTianqi Wang
Tianqi Wang
WJWeiwei Jin
Weiwei Jin
FLFuyou Liang
Fuyou Liang
JAJordi Alastruey
Jordi Alastruey
An abdominal aortic aneurysm (AAA) is usually asymptomatic until rupture, which is associated with extremely high mortality. Consequently, the early detection of AAAs is of paramount importance in reducing mortality; however, most AAAs are detected by medical imaging only incidentally. The aim of this study was to investigate the feasibility of machine learning-based pulse wave (PW) analysis for the early detection of AAAs using a database of in silico PWs. PWs in the large systemic arteries were simulated using one-dimensional blood flow modelling. A database of in silico PWs representative of subjects (aged 55, 65 and 75 years) with different AAA sizes was created by varying the AAA-related parameters with major impacts on PWs—identified by parameter sensitivity analysis—in an existing database of in silico PWs representative of subjects without AAAs. Then, a machine learning architecture for AAA detection was trained and tested using the new in silico PW database. The parameter sensitivity analysis revealed that the AAA maximum diameter and stiffness of the large systemic arteries were the dominant AAA-related biophysical properties considerably influencing the PWs. However, AAA detection by PW indexes was compromised by other non-AAA related cardiovascular parameters. The proposed machine learning model produced a sensitivity of 86.8 % and a specificity of 86.3 % in early detection of AAA from the photoplethysmogram PW signal measured in the digital artery with added random noise. The number of false positive and negative results increased with increasing age and decreasing AAA size, respectively. These findings suggest that machine learning-based PW analysis is a promising approach for AAA screening using PW signals acquired by wearable devices.

28 December 2024 in Scientific Reports
Verified
Journal Article
Open access
PDF file
LYLiu Yang
Liu Yang
YZYitao Zhang
Yitao Zhang
TWTianqi Wang
Tianqi Wang
Transjugular intrahepatic portosystemic shunt (TIPS) is a widely used surgery for portal hypertensive patients, whose potential postoperative complications are closely related to the hemodynamic condition of the portal venous system. The selection of shunt position in the surgery may affect the postoperative hemodynamics; however, it is difficult for clinical studies to investigate the influence. Therefore, this study aims to employ the computational model simulating TIPS to compare the hemodynamic differences resulting from different shunt positions, and also to investigate the influences of different geometrical model simplification strategies used in the TIPS simulation. For this purpose, the clinical data of two representative patients were retrospectively collected, based on which, the computational hemodynamic models of the portal venous systems after TIPS were constructed, incorporating three typical shunt positions (i.e. shunt at the left/main/right portal vein) and three types of geometrical model simplification. Results showed that among the models with different shunt positions, the area-averaged flow velocity magnitudes in the shunts were very similar, while the model with shunt at the main portal vein showed the lowest postoperative portal pressure and the smallest area of high wall shear stress near the portal venous bifurcation. Among the models using different geometrical model simplification strategies, the simulated blood pressures at the main portal veins were very similar, but showed marked differences near the shunt inlets. Moreover, the area-averaged flow velocity magnitudes in the shunts were almost the same, while the velocity distributions differed a lot, leading to the different spatial distributions of wall shear stress near the portal venous bifurcations and shunt walls. These results on one hand suggested that placing the shunt at the main portal vein is more beneficial for the patient; on the other hand, they proved the feasibility of utilizing simplified model to save computational cost without losing the accuracy when the pressure at the main portal vein is mainly focused on. These findings would assist clinical decision-making and promote more accurate and efficient TIPS simulations.

24 January 2025 in International Journal for Numerical Methods in Biomedical Engineering
Verified
Journal Article
Closed access
TWTianqi Wang
Tianqi Wang
YXYi Xiang
Yi Xiang
JWJitao Wang
Jitao Wang
JGJiaqi Gu
Jiaqi Gu
LYLing Yang
Ling Yang
XQXiaolong Qi
Xiaolong Qi

1 February 2025 in Physics of Fluids
Verified
Journal Article
Closed access
TWTianqi Wang
Tianqi Wang
KTKeming Tao
Keming Tao
WWWeiping Wang
Weiping Wang
XGXinyang Ge
Xinyang Ge
QPQiuyan Pei
Qiuyan Pei
The umbilical cord is a vital pathway for the fetus, which can bring oxygen/nutrition and take away waste products to maintain normal growth. Clinical studies found that abnormal coiling and nuchal cord conditions of the umbilical cord may be associated with fetal growth restriction. Although the hemodynamic environment due to the abnormal morphology is suspected to account for the abnormal growth, the specific influence of the abnormal coiling and nuchal cord conditions on the hemodynamics remains not fully understood. In this context, this study aims to investigate the hemodynamic effects of the variation of umbilical coiling index (UCI) and nuchal cord conditions in order to better address the issue. For this purpose, the computational model of a normal umbilical cord was constructed based on the ultrasound-measured geometrical parameters and blood flow velocity. On this basis, a series of computational models with lower/higher UCI and with/without nuchal cord were then constructed, which were used in the hemodynamic analysis and comparison. Results showed that (1) both abnormal UCI (lower and higher) and nuchal cord conditions significantly altered the hemodynamic environment; (2) the variations of UCI resulted in inverse tendencies between oscillatory shear index (OSI) and relative residence time (RRT); and (3) nuchal cord had minor impact on most hemodynamic variables, such as wall shear stress and RRT, but increased the area of higher OSI. These findings clarified the influence of different coiling and nuchal cord conditions on the hemodynamic environment of the umbilical cord, which would provide more insights into fetal growth restriction.

1 August 2025 in Physics of Fluids
Verified
Journal Article
Closed access
KTKeming Tao
Keming Tao
TWTianqi Wang
Tianqi Wang
Umbilical artery thrombosis (UAT), a catastrophic obstetric complication, is strongly associated with adverse fetal outcomes, yet its hemodynamic drivers remain poorly understood. Therefore, the present study aims to develop a computational model of UAT and thus investigate the hemodynamic effects of umbilical coiling on thrombus progression. For this purpose, first, the parametric geometrical models of umbilical artery with different umbilical coiling index (UCI) were constructed based on the ultrasound-measured data. Subsequently, hemodynamic simulations, including blood flow, platelet activation, coagulant generation, and bound platelet formation, were conducted by solving the convection–diffusion–reaction equations to mimic thrombus growth in the models with different UCI. Results demonstrated that thrombi propagated radially inward in spiral patterns, which progressively induced lumen narrowing, accelerated flow velocity, and increased flow resistance. More specifically, hypocoiling condition induced the most severe UAT, with an about fourfold increase in flow resistance compared to threefold and twofold increases in the normal coiling and hypercoiling models, respectively. Moreover, time-averaged wall shear stress inversely correlated with thrombosis, with hypocoiling exhibiting the lowest wall shear stress and the most extensive coagulant accumulation, collectively accelerating thrombosis. Besides, normal physiological flow velocities suppressed thrombus formation across all models, revealing that pathological flow reduction was a critical trigger of UAT. These findings suggest that hypocoiling condition would amplify UAT risk, especially under low-flow condition, highlighting the necessity for the integrated prenatal monitoring of both blood flow and UCI. This computational framework advances the insights into UAT pathogenesis and offers a potential direction for stratifying UAT risk in clinical settings.

31 December 2020 in Artery Research
Verified
Journal Article
Open access
PDF file
TWTianqi Wang
Tianqi Wang
JAJordi Alastruey
Jordi Alastruey
FLFuyou Liang
Fuyou Liang
Background: Abdominal aortic aneurysm (AAA) is usually asymptomatic and has an extremely high mortality if rupture occurs. Therefore, early detection and intervention are important. However, AAA is most often detected as an accidental finding during clinical imaging for other purposes [1]. Considering that AAA has a systemic impact on the biophysical properties of the cardiovascular system, pulse-wave-based diagnosis of AAA may be a potential approach for effective detection. There have been only a few studies of pulse wave propagation with AAA by using computational modelling or hydraulic simulators [2]. This study aims to provide some basic insights for pulse-wave-based diagnosis of AAA using computational modelling. Methods: We simulated blood flow in the larger systemic arteries using the 65-year-old baseline model from the pulse wave database in Charlton et al. [3] (see Figure, left). The influence on pulse waveforms of AAA morphology (including shape, maximum diameter and length) was simulated by adjusting the geometry of the abdominal aorta IV. In addition, the influence of the local AAA stiffness and global arterial stiffness (represented by carotid-femoral pulse wave velocity) was investigated by varying the relevant model parameters. Results: Results show that maximum diameter is the dominant morphological factor in reshaping the pulse waveform, introducing considerable changes in pulse wave indices. Moreover, both local and global arterial stiffness have a considerable impact on wave morphology in the presence of AAA (Figure, right). Conclusion: AAA produces considerable changes in pulse wave morphology that could be used for AAA detection by using pulse wave analysis.