Doosam Song

Prof. Doosam Song

SungKyunKwan Univerisity, Republic of Korea
+1
orcid

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2021 in Science of The Total Environment
Verified
Journal Article
Closed access
SPSowoo Park
Sowoo Park
YCYounhee Choi
Younhee Choi
Doosam SongDoosam Song
Doosam Song
EKEun Kyung Kim
Eun Kyung Kim

1 August 2008 in Applied Thermal Engineering
Verified
Journal Article
Closed access
Doosam SongDoosam Song
Doosam Song
TKTaeyeon Kim
Taeyeon Kim
SSSuwon Song
Suwon Song
SHSuckho Hwang
Suckho Hwang
SLSeung-Bok Leigh
Seung-Bok Leigh

1 December 2007 in Building and Environment
Verified
Journal Article
Closed access
TSTomonori Sakoi
Tomonori Sakoi
Kazuyo TsuzukiKazuyo Tsuzuki
Kazuyo Tsuzuki
SKShinsuke Kato
Shinsuke Kato
RORyozo Ooka
Ryozo Ooka
Doosam SongDoosam Song
Doosam Song
SZShengwei Zhu
Shengwei Zhu

1 August 2017 in Renewable and Sustainable Energy Reviews
Verified
Journal Article
Closed access
JLJunghun Lee
Junghun Lee
JKJeonggook Kim
Jeonggook Kim
Doosam SongDoosam Song
Doosam Song
JKJonghun Kim
Jonghun Kim
CJCheolyong Jang
Cheolyong Jang

10 May 2023 in Journal of Infection and Public Health
Verified
Journal Article
Open access
SPSowoo Park
Sowoo Park
Doosam SongDoosam Song
Doosam Song
The Wells-Riley equation has been extensively used to quantify the infection risk of airborne transmission indoors. This equation is difficult to apply to actual conditions because it requires measurement of the outdoor air supply rate, which vary with time and are difficult to quantify. The method of determining the fraction of inhaled air that has been exhaled previously by someone in a building using a CO2 concentration measurement can solve the limitations of the existing method. Using this method, the indoor CO2 concentration threshold can be determined to keep the risk of infection below certain conditions. Based on the calculation of the rebreathed fraction, an appropriate mean indoor CO2 concentration and required air exchange rate to control SARS-CoV-2 airborne transmission was calculated. The number of indoor occupants, ventilation rate, and the deposition and inactivation rates of the virus-laden aerosols were considered. The application of the proposed indoor CO2 concentration-based infection rate control was investigated through case studies in school classrooms and restaurants. In a typical school classroom environment with 20–25 occupants and an exposure time of 6–8 h, the average indoor CO2 concentration should be kept below 700 ppm to control the risk of airborne infection indoors. The ASHRAE recommended ventilation rate is sufficient when wearing a mask in classrooms. For a typical restaurant with 50–100 occupants and an exposure time of 2–3 h, the average indoor CO2 concentration should be kept below about 900 ppm. Residence time in the restaurant had a significant effect on the acceptable CO2 concentration. Given the conditions of the occupancy environment, it is possible to determine an indoor CO2 concentration threshold, and keeping the CO2 concentration lower than a certain threshold could help reduce the risk of COVID-19 infection.

1 June 2019 in Building and Environment
Verified
Journal Article
Closed access
Sungmin YoonSungmin Yoon
Sungmin Yoon
Doosam SongDoosam Song
Doosam Song
JKJoowook Kim
Joowook Kim
HLHyunwoo Lim
Hyunwoo Lim